This paper presents simulation of the transmission of biomedical signals (using ECG signal as an example) over wireless networks. Investigation of the effect of channel impairments including SNR, pathloss exponent, path delay and network impairments such as packet loss probability; on the diagnosability of the received ECG signal are presented. The ECG signal is transmitted through a wireless network system composed of two communication protocols; an 802.15.4- ZigBee protocol and an 802.11b protocol. The performance of the transmission is evaluated using higher order statistics parameters such as kurtosis and Negative Entropy in addition to the common techniques such as the PRD, RMS and Cross Correlation.
1 November 2009 in Journal of Medical Engineering & Technology
In this paper, an investigation of the spectral characteristics of intraluminal impedance signals using local Hilbert-Huang transform is presented. The impedance waveform may contain three main events: reflux event, swallow event and baseline region corresponding to no activity. The three events are analysed using local Hilbert-Huang transform to characterize the frequency contents of each event. In addition to the results of the Hilbert-Huang transform a time domain description of each event is presented.
10 August 2019 in Engineering, Technology & Applied Science Research
Body mass index (BMI) is the most widely used index for determining the fitness status of an individual. Midd-upper arm circumference (MUAC) is another commonly used anthropometric index, providing a simple measurement widely used for nutrition level screening. However, building a massive population database based on both BMI and MUAC measurements is time-consuming and may introduce errors due to instrumentations and different operators. In this paper, a measurement technique of BMI from photographic images of the upper arm is presented. Three parameters are measured from the subject photos with a scale attached, and these are upper arm length, sagittal plane middle arm thickness (SMT), and frontal plane middle thickness (FMT). Different parameters are derived from the SMT and the FMT. These parameters are used to study the correlation and measurements agreements with the BMI. It is found that all parameters related to SMT correlate very well with the BMI with correlation coefficients of more than 90%. In addition, the SMT measurement limits (both upper and lower) are acceptable and within the clinical significance range. Finally, the receiver operating characteristics analysis of both SMT and MUAC has been evaluated. The findings show that SMT is slightly better than MUAC since it gives excellent sensitivity (94.7%) without compromising the specificity (88.5%) when compared to the MUAC results.
27 March 2024 in Neural Computing and Applications