BACKGROUND: Tablet splitting is a well-established medical practice in clinical settings for multiple reasons, including cost savings and ease of swallowing. However, it does not necessarily result in weight-uniform half tablets. OBJECTIVES: To (a) investigate the effect of tablet characteristics on weight and content uniformity of half tablets, resulting from splitting 16 commonly used medications in the outpatient setting and (b) provide recommendations for safe tablet-splitting prescribing practices. METHODS: Ten random tablets from each of the selected medications were weighed and split by 5 volunteers (2 men and 3 women aged 25-44 years) using a knife. The selected medications were mirtazapine 30 mg, bromazepam 3 mg, oxcarbazepin 150 mg, sertraline 50 mg, carvedilol 25 mg, bisoprolol fumarate 10 mg, losartan 50 mg, digoxin 0.25 mg, amiodarone HCl 200 mg, metformin HCl 1,000 mg, glimepiride 4 mg, montelukast 10 mg, ibuprofen 600 mg, celecoxib 200 mg, meloxicam 15 mg, and sildenafil citrate 50 mg. The ...
19 May 2013 in Biopharmaceutics & Drug Disposition
To design oral controlled release (CR) hydrogel matrix tablets of etamsylate using various hydrophilic polymers. Additionally, to predict plasma concentration-time profiles of etamsylate released from different CR matrices. Characterization of the in-vitro release rate was performed by various model dependent and model independent approaches. A simple numerical convolution strategy was adopted to predict the in-vivo performance of all matrices from their in-vitro percent released data. The statistical analysis was conducted utilizing a student t-test and ANOVA. The release of etamsylate from all matrices showed a deviation from Fickian transport mechanism except; F2 followed Case II release whereas, F9 and F11 obeyed Fickian diffusion. CR hydrogel based-matrices (F4 and F11) demonstrated the maximum drug retardation and satisfied the USP release limits. Concentration–time profiles of etamsylate were predicted successfully from the in-vitro release data of all prepared matrices. Pharmacokinetic parameters of etamsylate CR hydrogel matrices were significantly changed with comparison to reference product except F1. The designed (F2-F11) matrices had the capability to extend the plasma level of etamsylate for an adequate time. However, F4 and F11 were considered the most ideal formulations for once daily application of etamsylate. The prediction of in-vivo pharmacokinetics of etamsylate was very useful to assess the rationality of the designed matrices for the practical application in humans.
The poor solubility and stability of 6-gingerol (6-G) could hamper its clinical applications. The aim of the current study was to develop a novel ultra-deformable cyclodextrin-functionalized transethoniosomes (CD-TENs) as a promising delivery system for 6-G. Transethoniosomes (TENs) are flexible niosomes (NVs) due to their content of ethanol and edge activators (EAs). CD-functionalized nanoparticles could improve drug solubility and stability compared to the corresponding nanovesicles. 6-G-loaded ethoniosomes (ENs) were formulated by the ethanol injection technique in the presence and absence of EA and CD to explore the impact of the studied independent variables on entrapment efficiency (EE%) and % 6-G released after 24 h (Q24h). According to the desirability criteria, F8 (CD-functionalized transethoniosomal formula) was selected as the optimized formulation. F8 demonstrated higher EE%, permeation, deformability and stability than the corresponding TENs, ENs and NVs. Additionally, F8 showed higher cytotoxic and anti-inflammatory activity than pure 6-G. The synergism between complexation with CD and novel ultra-deformable nanovesicles (TENs) in the form of CD-TENs can be a promising drug delivery carrier for 6-G.
4 February 2015 in Biopharmaceutics & Drug Disposition
A new and simple HPLC assay method was developed and validated for the determination of etamsylate in human plasma. After protein precipitation with 6% perchloric acid, satisfactory separation was achieved on a HyPURITY C18 column (250 mm × 4.6 mm, 5 μm) using a mobile phase comprising 20 mM sodium dihydrogen phosphate-2 hydrate (pH was adjusted to 3.5 by phosphoric acid) and acetonitrile at a ratio of 95:5 v/v. The elution was isocratic at ambient temperature with a flow rate of 0.75 ml/min. Allopurinol was used as internal standard. The calibration curve was linear over the range from 0.25 to 20 μg/ml (r2 = 0.999). The limit of quantification for etamsylate in plasma was 0.25 μg/ml. The within day coefficient of variance (%CV) ranged from 3.9% to 10.2%, whereas the between-day %CV ranged from 3.1% to 8.7%. The assay method has been successfully used to estimate the pharmacokinetics of etamsylate after oral administration of a 500 mg tablet under fasting conditions to 24 healthy Egyptian human male volunteers. Various pharmacokinetic parameters including AUC0–t, AUC0–∞, Cmax, Tmax, t1/2, MRT, Cl/F, and Vd/F were determined from plasma concentration–time profile of etamsylate.