Syed Mohammad Mirhosseini

Dr. Syed Mohammad Mirhosseini

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2019 in Cold Regions Science and Technology
Verified
Journal Article
Closed access
AKAmir Kalhor
Amir Kalhor
MGMahmoud Ghazavi
Mahmoud Ghazavi
MRMahya Roustaei
Mahya Roustaei
SMSyed Mohammad Mirhosseini
Syed Mohammad Mirhosseini

17 February 2021 in International Journal of Construction Management
Verified
Journal Article
Closed access
AAAbolfazl Alvand
Abolfazl Alvand
SMSyed Mohammad Mirhosseini
Syed Mohammad Mirhosseini
MEMohammad Ehsanifar
Mohammad Ehsanifar
EZEhsanollah Zeighami
Ehsanollah Zeighami
AMAmir Mohammadi
Amir Mohammadi
Nowadays, focusing on risk management is one of the core objectives of any organization. Failing to assess project risks during the planning stage could be hazardous throughout the entire project lifecycle. Therefore, risk assessment is so important and various methods have been developed for it. One of the most important risk assessment methods is Failure Mode and Effects Analysis (FMEA). Despite the widespread applications of this method in various industries and organizations, FMEA is associated with some shortcomings that can lead to unrealistic results. In order to identify and evaluate the risks affecting construction projects and cover some shortcomings of the FMEA technique suggested an integrated model based on FMEA, Stepwise Weight Assessment Ratio Analysis (SWARA), and Weighted Aggregated Sum Product Assessment (WASPAS) methods under fuzzy environment in this research. To this end, a case study about the construction projects of the Iranian Road and Urban Development Organization is presented to illustrate the potential benefits and application of the proposed integrated approach. The results suggest that the new integrated model is more capable and accurate in identifying and prioritizing risk compared to the conventional FMEA technique and can provide useful information to help manage the risks of construction projects.

13 February 2017 in International Journal of Geotechnical Engineering
Verified
Journal Article
Closed access
NMN. R. Malidarreh
N. R. Malidarreh
ISI. Shooshpasha
I. Shooshpasha
SMSyed Mohammad Mirhosseini
Syed Mohammad Mirhosseini
Mehdi DehestaniMehdi Dehestani
Mehdi Dehestani
The mechanical behaviour of artificially cement-treated Babolsar sand reinforced with sack, polyethylene terephthalate (PET) and polypropylene (PP) fibres is studied in this paper. Tests were conducted on cemented sand samples prepared at a relative density of 70%, with and without reinforcements on direct shear and triaxial apparatuses. Effects of parameters such as fibre content (FC), fibre type and normal or confining pressure (NP or CP) have been studied. Test results revealed that the addition of fibres had a significant effect on the behaviour of cemented sand. However, PP fibres are much more effective reinforcing materials than sack and PET fibres. A comparison between the results of direct shear tests and triaxial tests indicated that the fibre efficiency and its effect on soil behaviour is much more significant in triaxial tests compared with those in direct shear tests.

2 November 2016 in Shock and Vibration
Verified
Journal Article
Open access
PDF file
MSMohamad Reza Soheyli
Mohamad Reza Soheyli
AAAmir Akhaveissy
Amir Akhaveissy
SMSyed Mohammad Mirhosseini
Syed Mohammad Mirhosseini
Despite growing demands for structures in water transportation tunnels, underground installations, subsurface dams, and subterranean channels, there is limited field knowledge about the dynamic behavior of these structures in the face of near-fault earthquakes or impulse excitations. This study conducted a large-scale test on underground tunnel excited by two close-in subsurface explosions. The horizontal and vertical acceleration were recorded on the vertical wall of the tunnel and the free field data including the acceleration on the ground surface at 11-meter distance from the tunnel. The frequency domain analysis of recorded results determined the frequency 961 Hz and 968 Hz for 1.69 kg and 2.76 kg equivalent T.N.T., respectively. Then, finite element analysis results were compared with the test data. The comparisons demonstrated a good correlation and satisfied the field data. Finally, based on numerical modeling, a parametric study was applied to determine the effects of shear wave velocity distance of the crater with respect to the tunnel on impulse response of the tunnel.

18 March 2020 in Arabian Journal of Geosciences
Verified
Journal Article
Closed access
PDF file
NFNima Farshidfar
Nima Farshidfar
AKAmin Keshavarz
Amin Keshavarz
SMSyed Mohammad Mirhosseini
Syed Mohammad Mirhosseini

1 October 2020 in Structures
Verified
Journal Article
Closed access
EKEhsan Kazeminezhad
Ehsan Kazeminezhad
MKMohammad Taghi Kazemi
Mohammad Taghi Kazemi
SMSyed Mohammad Mirhosseini
Syed Mohammad Mirhosseini