Imran Khan

Mr. Imran Khan

University of Paris saclay
+2
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 May 2019 in Electronics
Verified
Journal Article
Open access
PDF file
Kamran ZebKamran Zeb
Kamran Zeb
SISaif Ul Islam
Saif Ul Islam
Waqar UddinWaqar Uddin
Waqar Uddin
IKImran Khan
Imran Khan
Muhammad IshfaqMuhammad Ishfaq
Muhammad Ishfaq
Hee-Je KimHee-Je Kim
Hee-Je Kim
Conventional Energy Resources (CER) are being rapidly replaced by Renewable Energy Resources (RER) due to their abundant, environmentally friendly, clean, and inexhaustible nature. In recent years, Solar Photovoltaic (SPV) energy installation is booming at a rapid rate among various RER. Grid-Connected PVS required advance DC-link controllers to overcome second harmonic ripple and current controllers to feed-in high-quality current to the grid. This paper successfully presents the design of a Fuzzy-Logic Based PI (F-PI) and Fuzzy-Logic based Sliding Mode Controller (F-SMC) for the DC-link voltage controller and Proportional Resonant (PR) with Resonant Harmonic Compensator (RHC) as a current controller for a Single-Phase Two-Stages Grid-connected Transformerless (STGT) Photovoltaic (PV) Inverter. The current controller is designed with and without a feedforward PV power loop to improve dynamics and control. A Second Order General Integral (SOGI)-based Phase Lock Loop (PLL) is also designed that has a fast-dynamic response, fast-tracking accuracy, and harmonic immunity. A 3 kW STGT-PV system is used for simulation in Matlab/Simulink. A comparative assessment of designed controllers is carried out with a conventionally well-tuned PI controller. The designed controllers improve the steady-state and dynamic performance of the grid-connected PV system. In addition, the results, performance measure analysis, and harmonics contents authenticate the robustness, fastness, and effectiveness of the designed controllers, related to former works.

28 July 2018 in Energies
Verified
Journal Article
Open access
PDF file
Kamran ZebKamran Zeb
Kamran Zeb
IKImran Khan
Imran Khan
Waqar UddinWaqar Uddin
Waqar Uddin
MKMuhammad Adil Khan
Muhammad Adil Khan
PSP. Sathishkumar
P. Sathishkumar
Hee-Je KimHee-Je Kim
Hee-Je Kim
°CThe research significance of various scientific aspects of photovoltaic (PV) systems has increased over the past decade. Grid-tied inverters the vital elements for the effective interface of Renewable Energy Resources (RER) and utility in the distributed generation system. Currently, Single-Phase Transformerless Grid-Connected Photovoltaic (SPTG-CPV) inverters (1–10 kW) are undergoing further developments, with new designs, and interest of the solar market. In comparison to the transformer (TR) Galvanic Isolation (GI)-based inverters, its advantageous features are lower cost, lighter weight, smaller volume, higher efficiency, and less complexity. In this paper, a review of SPTG-CPV inverters has been carried out. The basic operational principles of all SPTG-CPV inverters are presented in details for positive, negative, and zero cycles. A comprehensive analysis of each topology has been deliberated. A comparative assessment is also performed based on weaknesses, strengths, component ratings, efficiency, total harmonic distortion (THD), semiconductor device losses, and leakage current of various SPTG-CPV inverters schemes. Typical PV inverter structures and control schemes for grid connected three-phase system and single-phase systems are also discussed, described, and reviewed. Comparison of various industrial grids-connected PV inverters is also performed. Loss analysis is also performed for various topologies at 1 kW. Selection of appropriate topologies for their particular application is thoroughly presented. Then, discussion and forthcoming progress are emphasized. Lastly, the conclusions are presented. More than 100 research publications on the topic of SPTG-CPV inverter topologies, configurations, and control schematics along with the recent developments are thoroughly reviewed and classified for quick reference.

19 December 2018 in Electronics
Verified
Journal Article
Open access
PDF file
SISaif Ul Islam
Saif Ul Islam
Kamran ZebKamran Zeb
Kamran Zeb
Waqar UddinWaqar Uddin
Waqar Uddin
IKImran Khan
Imran Khan
Muhammad IshfaqMuhammad Ishfaq
Muhammad Ishfaq
Hee-Je KimHee-Je Kim
Hee-Je Kim
This paper presents the design and analysis of a proportional resonant controller with a resonant harmonic compensator and switch-type fault current limiter, as a fault-ride through strategy for a three-phase, grid-connected photovoltaic (PV) system under normal conditions and asymmetrical faults. The switch-type fault limiter comprised of current-limiting inductors, a bridge rectifier, a snubber capacitor, linear transformers, and energy absorption bypass. Furthermore, a critical and analytical comparison of switch-type fault limiters is carried out, with the conventional crowbar as the fault-ride through strategy, in combination with a conventionally tuned proportional integrator controller. The designed fault-ride through strategies with proportional integrator and proportional resonant controllers with resonant harmonic compensators are tested at the point of common coupling of the photovoltaic system and at a distance of 19 km from the point of common coupling, in order to analyze the impacts of fault parameter with respect to location. A MATLAB/Simulink model of a 100 kW three-phase grid-connected photovoltaic system is used for analysis. The simulation results of the proposed switch-type fault limiter with proportional resonant controller effectively validate the stable, ripple-free, and robust response compared to all other configurations. In addition, it is also verified that the grid faults on the PV system have a significant impact on fault type, and less impact on fault location.

25 October 2019 in Energies
Verified
Journal Article
Open access
PDF file
Waqar UddinWaqar Uddin
Waqar Uddin
Kamran ZebKamran Zeb
Kamran Zeb
MKMuhammad Adil Khan
Muhammad Adil Khan
Muhammad IshfaqMuhammad Ishfaq
Muhammad Ishfaq
IKImran Khan
Imran Khan
CLCheewoo Lee
Cheewoo Lee
The modular multilevel converter (MMC) has been prominently used in medium- and high-power applications. This paper presents the control of output and circulating current of MMC using sliding mode control (SMC). The design of the proposed controller and the relation between control parameters and validity condition are based on the system dynamics. The proposed designed controller enables the system to track its reference values. The controller is designed to control both output current and circulating current along with suppression of second harmonics contents in circulating current. Furthermore, the capacitor voltage and energy of the converter are also regulated. The control of output current is carried out in d q -axis as well as in α β − a x i s with first-order switching law. However, a second-order switching law-based super twisting algorithm is used for controlling circulating current and suppression of its second harmonics contents. The stability of the controlled system is numerically calculated and verified by Lyapunov stability conditions. Moreover, the simulation results of the proposed controller are critically compared with the conventional proportional resonant (PR) controller to verify the effectiveness of the proposed control strategy. The proposed controller attains faster dynamic response and minimizes steady-state error comparatively. The simulation of the MMC model is carried out in MATLAB/Simulink.

31 January 2019 in Energies
Verified
Journal Article
Open access
PDF file
IKImran Khan
Imran Khan
Kamran ZebKamran Zeb
Kamran Zeb
Waqar UddinWaqar Uddin
Waqar Uddin
SISaif Ul Islam
Saif Ul Islam
Muhammad IshfaqMuhammad Ishfaq
Muhammad Ishfaq
Hee-Je KimHee-Je Kim
Hee-Je Kim
High penetration of large capacity wind turbines into power grid has led to serious concern about its influence on the dynamic behaviors of the power system. Unbalanced grid voltage causing DC-voltage fluctuations and DC-link capacitor large harmonic current which results in degrading reliability and lifespan of capacitor used in voltage source converter. Furthermore, due to magnetic saturation in the generator and non-linear loads distorted active and reactive power delivered to the grid, violating grid code. This paper provides a detailed investigation of dynamic behavior and transient characteristics of Doubly Fed Induction Generator (DFIG) during grid faults and voltage sags. It also presents novel grid side controllers, Adaptive Proportional Integral Controller (API) and Proportional Resonant with Resonant Harmonic Compensator (PR+RHC) which eliminate the negative impact of unbalanced grid voltage on the DC-capacitor as well as achieving harmonic filtering by compensating harmonics which improve power quality. Proposed algorithm focuses on mitigation of harmonic currents and voltage fluctuation in DC-capacitor making capacitor more reliable under transient grid conditions as well as distorted active and reactive power delivered to the electric grid. MATLAB/Simulink simulation of 2 MW DFIG model with 1150 V DC-linked voltage has been considered for validating the effectiveness of proposed control algorithms. The proposed controllers performance authenticates robust, ripples free, and fault-tolerant capability. In addition, performance indices and Total Harmonic Distortions (THD) are also calculated to verify the robustness of the designed controller.

12 April 2019 in Electronics
Verified
Journal Article
Open access
PDF file
SISaif Ul Islam
Saif Ul Islam
Kamran ZebKamran Zeb
Kamran Zeb
Waqar UddinWaqar Uddin
Waqar Uddin
IKImran Khan
Imran Khan
Muhammad IshfaqMuhammad Ishfaq
Muhammad Ishfaq
Hee-Je KimHee-Je Kim
Hee-Je Kim
This paper emphasizes the design and investigation of a new optimization scheme for a grid-connected photovoltaic system (PVS) under unbalance faults. The proposed scheme includes fuzzy logic controller (FLC) based on the Levenberg–Marquardt (LM) optimization technique in coordination with bridge-type-fault-current limiter (BFCL) as the fault ride through (FRT) Strategy. The LM optimization-based control is an iterative process with a fast and robust response and is always convergent. The BFCL reduces the fault currents to rated values without compromising at ripples. A keen and critical comparison of the designed strategy is carried out with a conventionally tuned proportional-integral (PI) controller in coordination with the crowbar FRT strategy. A 100kW MATLAB/Simulink model of a photovoltaic system is used for simulation and analysis of unbalance faults at the point of common-coupling (PCC) and at 5 km away from PCC. It is found that grid-connected PVS is highly influenced by the fault type and less effected by the distribution line length. The simulation results authenticated smooth, stable, ripples with free, robust, and fault-tolerant behavior of the proposed scheme.