Gold is of considerable interest for electrochemical active surfaces because thiol-modified chemicals and biomolecules can be easily immobilized with a simple procedure. However, most gold surfaces are damaged with repetitive measurements, so they are difficult to reuse. Here we demonstrate a novel electrochemical cleaning method of gold surfaces to reuse electrodes with a simple protocol that is easy and nontoxic. This electrochemical cleaning consists of two steps by using different solutions. The 1st step is a cyclic voltammetry sweep using a very low concentration of sulfuric acid, and the 2nd step is a cyclic voltammetry sweep using potassium ferricyanide. Different cleaning methods were also considered for comparison. Consequently, after assembling and desorption of the cell and antigen, the changes in gold electrode performance, as immunosensor and cytosensor, were investigated by electrochemical impedance and cyclic voltammetry. It was found that repetitive measurement is possible until five times while maintaining the reproducibility. It is believed that this method is capable of enabling reuse of gold electrodes and can be used for long-term and accurate monitoring of biological effects, especially at a low cost.
18 September 2017 in ACS Applied Materials & Interfaces
Polypyrrole (Ppy) is a biologically compatible polymer that is used as a matrix, in which drugs and enzymes can be incorporated by doping. Here, we suggest an inventive application of Ppy as a biorecognition film encapsulated with an antibody (Ab) as an alternative strategy for the on-site multistep functionalization of thiol-based self-assembled monolayers. The fabrication steps of the recognition films were followed by dropping pyrrole and Ab mixed solutions onto the electrode and obtaining a thin film by direct current electropolymerization. The efficiency of Ab immobilization was studied by using fluorescence microscopy and electrochemical (EC) methods. Finally, the Ab density was increased and immobilized in 1 min, and the sensing performance as an EC immunosensor was demonstrated using α-fetoprotein with a limit of detection of 3.13 pg/mL and sensing range from 1 pg/mL to 100 ng/mL. This study demonstrates the potential for electrochemical functionalization of biomolecules with high affinity and rapidity.
Nicotinamide adenine dinucleotide (NADH) is an important cofactor involved in metabolic redox reactions in living cells. The detection of NADH in living animal cells is a challenge. We developed a one-step monitoring method for NADH via an electrocatalytic reaction that uses a surface-modified, screen-printed electrode (SPE) having a redox active monolayer 4′-mercapto-N-phenlyquinone diamine (NPQD) formed by a self-assembled monolayer (SAM) of an aromatic thiol, 4-aminothiophenol (4-ATP). This electrode has a limit of detection (LOD) of 0.49 μM and a sensitivity of 0.0076 ± 0.0006 μM/μA in cell culture media, which indicates that it retains its selectivity. The applicability of this NADH sensor was demonstrated for the first time by cell viability monitoring via NADH-sensing in cell culture supernatants.
Gold (Au) is of considerable interest for electrochemically active surfaces because thiol-modified chemicals and biomolecules can be easily immobilized through a simple procedure. However, most Au surfaces are damaged after repetitive measurements, making them difficult to reuse. Here, we present a novel electrochemical (EC) etching method for Au surfaces that enables electrode reuse through a simple, nontoxic, and straightforward protocol. This process, referred to as double-step EC etching (DSEE), consists of two sequential steps: (i) a cyclic voltammetry (CV) sweep in a very low concentration of H2SO4, followed by (ii) a CV sweep in K3Fe-(CN)6. For comparison, alternative etching methods were also evaluated. After the assembly and subsequent desorption of cells and antigens, changes in the performance of the Au electrode as both an immunosensor and a cytosensor were examined using EC impedance spectroscopy and CV. Repetitive measurements were found to be feasible for up to five cycles while maintaining reproducibility. We believe that this Au electrode reuse method can be applied to long-term, cost-effective, and accurate monitoring of biological effects.