Suk-Min Hong

Suk-Min Hong

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 June 2018 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
SHSuk-Min Hong
Suk-Min Hong
Chang-Hoon ChoiChang-Hoon Choi
Chang-Hoon Choi
AMArthur W. Magill
Arthur W. Magill
NSN. Jon Shah
N. Jon Shah
JFJarg Felder
Jarg Felder
MRI using nuclei other than protons is of clinical interest due to the important role of these nuclei in cellular processes. Phosphorous-31 (31P), for example, plays an important role in energy metabolism. However measurement of 31P can be challenging, as the receive signal is weak compared to that of proton (1H). Consequently, it is often necessary to integrate 1H elements for localisations and B0 shimming in RF coils intended for 31P measurements. Good decoupling between the 1H and the 31P elements is therefore essential. In this study, bent dipole antennas tuned to 1H were integrated with a four channel 31P loop coil array, in a manner providing strong geometric decoupling between dipoles and loops. As the physical length of a resonant dipole antenna is too long at 3T, the dipole antennas were bent around the load. The loss of 31P elements due to the presence of the dipole antennas was evaluated by measuring scattering parameters and comparing the SNR of 31P spectra with and without the presence of the dipole antennas. The performance of the bent dipole antenna was evaluated by simulation and sensitivity measurement. The Q-factors and the SNR of the four-loop array were reduced by less than 5% when the bent dipole antennas were introduced. The measured sensitivity of the bent dipole was higher (15%) than that of dual-tuned birdcage. The combined bent dipole and loop array is therefore a promising design for 1H/31P applications at 3T.

3 December 2021 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
Chang-Hoon ChoiChang-Hoon Choi
Chang-Hoon Choi
SHSuk-Min Hong
Suk-Min Hong
JFJorg Felder
Jorg Felder
LTLutz Tellmann
Lutz Tellmann
JSJurgen Scheins
Jurgen Scheins
NSN. Jon Shah
N. Jon Shah
Simultaneous MR-PET/-SPECT is an emerging technology that capitalises on the invaluable advantages of both modalities, allowing access to numerous sensitive tracers and superior soft-tissue contrast alongside versatile functional imaging capabilities. However, to optimise these capabilities, concurrent acquisitions require the MRI antenna located inside the PET/SPECT field-of-view to be operated without compromising any aspects of system performance or image quality compared to the stand-alone instrumentation. Here, we report a novel gamma-radiation-transparent antenna concept. The end-fed J-shape antenna is particularly adept for hybrid ultra-high field MR-PET/-SPECT applications as it enables all highly attenuating materials to be placed outside the imaging field-of-view. Furthermore, this unique configuration also provides advantages in stand-alone MR applications by reducing the amount of coupling between the cables and the antenna elements, and by lowering the potential specific absorption rate burden. The use of this new design was experimentally verified according to the important features for both ultra-high field MRI and the 511 keV transmission scan. The reconstructed attenuation maps evidently showed much lower attenuation (~15%) for the proposed array when compared to the conventional dipole antenna array since there were no high-density components. In MR, it was observed that the signal-to-noise ratio from the whole volume obtained using the proposed array was comparable to that acquired by the conventional array which was also in agreement with the simulation results. The unique feature, J-shape array, would enable simultaneous MR-PET/-SPECT experiments to be conducted without unduly compromising any aspects of system performance and image quality compared to the stand-alone instrumentation.

22 January 2019 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
SHSuk-Min Hong
Suk-Min Hong
Chang-Hoon ChoiChang-Hoon Choi
Chang-Hoon Choi
NSN. Jon Shah
N. Jon Shah
JFJörg Felder
Jörg Felder
Proton magnetic resonance imaging (MRI) can be combined with signals from non-proton nuclei (X-nuclei) to provide metabolic information. Double-resonant coils are often used for X-nuclei MR studies where the proton element is employed for scout imaging and B 0 shimming. This work describes the development of a new double-resonant coil capable of operating at both proton and X-nuclei frequencies. The proposed design extends the wheel-and-spoke coil, which allows for quadrature drive, by adding an extra ring outside the coil to achieve double-resonance. Furthermore, in order to maximise SNR by increasing the filling factor, the shape of the coil has been modified to a helmet style making it suitable for brain applications. The performance of the double-resonant helmet coil was evaluated by simulation and MR measurements. The helmet coil was successfully tuned to the 1 H/ 31 P resonance frequencies of a 3T MR scanner, with high isolation between the two quadrature ports. MR measurements of a phantom were carried out, and the averaged sensitivity of the double-resonant helmet coil over the whole phantom was found to be higher than that of the conventional double-tuned birdcage coil at both frequencies.

8 April 2020 in Physics in Medicine & Biology
Verified
Journal Article
Open access
PDF file
Chang-Hoon ChoiChang-Hoon Choi
Chang-Hoon Choi
TFTim Felder
Tim Felder
JFJörg Felder
Jörg Felder
LTLutz Tellmann
Lutz Tellmann
SHSuk-Min Hong
Suk-Min Hong
KZKarl Ziemons
Karl Ziemons
Prostate cancer is one of the most common cancers among men and its early detection is critical for its successful treatment. The use of multimodal imaging, such as MR-PET, is most advantageous as it is able to provide detailed information about the prostate. However, as the human prostate is flexible and can move into different positions under external conditions, it is important to localise the focused region-of-interest using both MRI and PET under identical circumstances. In this work, we designed five commonly used linear and quadrature radiofrequency surface coils suitable for hybrid MR-PET use in endorectal applications. Due to the endorectal design and the shielded PET insert, the outer face of the coils investigated was curved and the region to be imaged was outside the volume of the coil. The tilting angles of the coils were varied with respect to the main magnetic field direction. This was done to approximate the various positions from which the prostate could be imaged. The transmit efficiencies and safety excitation efficiencies from simulations, together with the signal-to-noise ratios from the MR images were calculated and analysed. Overall, it was found that the overlapped loops driven in quadrature were superior to the other types of coils we tested. In order to determine the effect of the different coil designs on PET, transmission scans were carried out, and it was observed that the differences between attenuation maps with and without the coils were negligible. The findings of this work can provide useful guidance for the integration of such coil designs into MR-PET hybrid systems in the future.

28 June 2024 in IEEE Open Journal of Engineering in Medicine and Biology
Verified
Journal Article
Open access
Chang-Hoon ChoiChang-Hoon Choi
Chang-Hoon Choi
MBMaximilian Bruch
Maximilian Bruch
SHSuk-Min Hong
Suk-Min Hong
SKSandra Krause
Sandra Krause
CSCarina Stegmayr
Carina Stegmayr
NSN. Jon Shah
N. Jon Shah
Goal: This study presents a novel MRI coil design approach explicitly tailored for chick embryo measurements, with the primary objective of improving sensitivity and coverage. Methods: The limitations posed by conventional birdcage coils were addressed by introducing a curvature feature into a standard coil. The performance of the modified coil was assessed using EM simulations and experimental evaluations, which were subsequently validated using a 7 T MRI scanner. A comparative analysis was conducted against a standard quadrature low-pass birdcage coil to evaluate key factors. Results: The proposed coil demonstrated improved SNR and uniformity, particularly in the proximity of the end-rings. These results were consistent with the findings obtained from the simulations. Conclusions: The use of our innovative birdcage coil design holds promise and offers practical potential for in ovo studies.

28 November 2023 in IEEE Access
Verified
Journal Article
Open access
SHSuk-Min Hong
Suk-Min Hong
Chang-Hoon ChoiChang-Hoon Choi
Chang-Hoon Choi
NSN. Jon Shah
N. Jon Shah
JFJörg Felder
Jörg Felder
Magnetic resonance imaging (MRI) is an invaluable tool for the diagnosis and study of brain function. Central to the MRI system, the radio frequency (RF) coil plays a dual role: stimulating spins and receiving the MR signal, enabling the generation of detailed images from inside the body. Compared to using linear polarised (LP) methods, the efficiency of the RF coil can be improved by leveraging circular polarised (CP) driving methods, which operate with at least two elements and 90° phase input if the geometrical dimensions are identical. Coil efficiency can also be improved with the use of a multi-channel phased array receive-only coils, as they provide higher SNR compared to volume coils. Generally, all elements of phased array coils operate in LP mode. However, if the LP elements are replaced by dimension-matched CP elements, the SNR of the phased array coil can be further increased, although this results in an increased number of channels and more coupling problems between channels. This study introduces a novel single-channel butterfly coil uniquely capable of operating in CP mode. This is achieved by operating the CP element with asymmetrical tuning and a split resonance peak. The performance of the single-channel CP butterfly coil was evaluated in simulations and MR measurements, and the results were compared to those from single-channel LP coils. The results show that the single-channel CP butterfly coil is a good solution for increasing SNR in phased array receive-only coils.