Nicola Calisi

Dr. Nicola Calisi

Department of Industrial Engineering, Università degli Studi di Firenze, 50139 Florence, Italy
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2018 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
PSP. Salvo
P. Salvo
BMB. Melai
B. Melai
Nicola CalisiNicola Calisi
Nicola Calisi
CPC. Paoletti
C. Paoletti
FBFrancesca Bellagambi
Francesca Bellagambi
Fabio Di FrancescoFabio Di Francesco
Fabio Di Francesco

16 May 2011 in Green Chemistry
Verified
Journal Article
Closed access
PDF file
Fabio Di FrancescoFabio Di Francesco
Fabio Di Francesco
Nicola CalisiNicola Calisi
Nicola Calisi
MCMatteo Creatini
Matteo Creatini
BMBernardo Melai
Bernardo Melai
PSPietro Salvo
Pietro Salvo
CCCinzia Chiappe
Cinzia Chiappe
The kinetics of water vapour sorption by several anhydrous hydrophobic and hydrophilic ionic liquids (ILs) were gravimetrically determined at 25 °C and two levels of humidity, namely 43 and 81%. A simple equation was used to fit the data. The kinetic parameters obtained from the different ILs were compared and the differences were related to the IL structures. Results showed that even hydrophobic ILs absorb water at an unexpected speed.

1 February 2021 in Materials Science and Engineering: C
Verified
Journal Article
Closed access
EBEmilia Benassai
Emilia Benassai
Massimo Del BubbaMassimo Del Bubba
Massimo Del Bubba
CAClaudia Ancillotti
Claudia Ancillotti
ICIlaria Colzi
Ilaria Colzi
CGCristina Gonnelli
Cristina Gonnelli
SRSandra Ristori
Sandra Ristori

1 May 2017 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
PSP. Salvo
P. Salvo
Nicola CalisiNicola Calisi
Nicola Calisi
BMB. Melai
B. Melai
BCB. Cortigiani
B. Cortigiani
MMM. Mannini
M. Mannini
Fabio Di FrancescoFabio Di Francesco
Fabio Di Francesco


1 January 2017 in International Journal of Nanomedicine
Verified
Journal Article
Open access
PDF file
PSPietro Salvo
Pietro Salvo
Nicola CalisiNicola Calisi
Nicola Calisi
BMBernardo Melai
Bernardo Melai
VDValentina Dini
Valentina Dini
CPClara Paoletti
Clara Paoletti
MRMarco Romanelli
Marco Romanelli
Foot ulcers account for 15% of comorbidities associated with diabetes. Presently, no device allows the status of foot ulcers to be continuously monitored when patients are not hospitalized. In this study, we describe a temperature and a pH sensor capable of monitoring diabetic foot and venous leg ulcers developed in the frame of the seventh framework program European Union project SWAN-iCare (smart wearable and autonomous negative pressure device for wound monitoring and therapy). Temperature is measured by exploiting the variations in the electrical resistance of a nanocomposite consisting of multiwalled carbon nanotubes and poly(styrene-b-(ethylene-co-butylene)-b-styrene). The pH sensor used a graphene oxide (GO) layer that changes its electrical potential when pH changes. The temperature sensor has a sensitivity of ~85 Ω/°C in the range 25°C–50°C and a high repeatability (maximum standard deviation of 0.1% over seven repeated measurements). For a GO concentration of 4 mg/mL, the pH sensor has a sensitivity of ~42 mV/pH and high linearity (R2=0.99).