Paul Armitage

Paul Armitage


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2016 in NeuroImage
Verified
Journal Article
Open access
AHAnna K. Heye
Anna K. Heye
MTMichael J Thrippleton
Michael J Thrippleton
PAPaul Armitage
Paul Armitage
MHMaria Del C. Valdés Hernández
Maria Del C. Valdés Hernández
SMStephen D. Makin
Stephen D. Makin
JWJoanna M Wardlaw
Joanna M Wardlaw
There is evidence that subtle breakdown of the blood-brain barrier (BBB) is a pathophysiological component of several diseases, including cerebral small vessel disease and some dementias. Dynamic contrast-enhanced MRI (DCE-MRI) combined with tracer kinetic modelling is widely used for assessing permeability and perfusion in brain tumours and body tissues where contrast agents readily accumulate in the extracellular space. However, in diseases where leakage is subtle, the optimal approach for measuring BBB integrity is likely to differ since the magnitude and rate of enhancement caused by leakage are extremely low; several methods have been reported in the literature, yielding a wide range of parameters even in healthy subjects. We hypothesised that the Patlak model is a suitable approach for measuring low-level BBB permeability with low temporal resolution and high spatial resolution and brain coverage, and that normal levels of scanner instability would influence permeability measurements. DCE-MRI was performed in a cohort of mild stroke patients (n=201) with a range of cerebral small vessel disease severity. We fitted these data to a set of nested tracer kinetic models, ranking their performance according to the Akaike information criterion. To assess the influence of scanner drift, we scanned 15 healthy volunteers that underwent a "sham" DCE-MRI procedure without administration of contrast agent. Numerical simulations were performed to investigate model validity and the effect of scanner drift. The Patlak model was found to be most appropriate for fitting low-permeability data, and the simulations showed vp and K(Trans) estimates to be reasonably robust to the model assumptions. However, signal drift (measured at approximately 0.1% per minute and comparable to literature reports in other settings) led to systematic errors in calculated tracer kinetic parameters, particularly at low permeabilities. Our findings justify the growing use of the Patlak model in low-permeability states, which has the potential to provide valuable information regarding BBB integrity in a range of diseases. However, absolute values of the resulting tracer kinetic parameters should be interpreted with extreme caution, and the size and influence of signal drift should be measured where possible.

21 February 2017 in Trials
Verified
Journal Article
Open access
PDF file
FCFrancesca Chappell
Francesca Chappell
MHMaria Del C. Valdés Hernández
Maria Del C. Valdés Hernández
SMStephen D. Makin
Stephen D. Makin
KSKirsten Shuler
Kirsten Shuler
ESEleni Sakka
Eleni Sakka
JWJoanna M Wardlaw
Joanna M Wardlaw
White matter hyperintensities (WMHs) are commonly seen on in brain imaging and are associated with stroke and cognitive decline. Therefore, they may provide a relevant intermediate outcome in clinical trials. WMH can be measured as a volume or visually on the Fazekas scale. We investigated predictors of WMH progression and design of efficient studies using WMH volume and Fazekas score as an intermediate outcome. We prospectively recruited 264 patients with mild ischaemic stroke and measured WMH volume, Fazekas score, age and cardiovascular risk factors at baseline and 1 year. We modelled predictors of WMH burden at 1 year and used the results in sample size calculations for hypothetical randomised controlled trials with different analysis plans and lengths of follow-up. Follow-up WMH volume was predicted by baseline WMH: a 0.73-ml (95% CI 0.65–0.80, p < 0.0001) increase per 1-ml baseline volume increment, and a 2.93-ml increase (95% CI 1.76–4.10, p < 0.0001) per point on the Fazekas scale. Using a mean difference of 1 ml in WMH volume between treatment groups, 80% power and 5% alpha, adjusting for all predictors and 2-year follow-up produced the smallest sample size (n = 642). Other study designs produced samples sizes from 2054 to 21,270. Sample size calculations using Fazekas score as an outcome with the same power and alpha, as well as an OR corresponding to a 1-ml difference, were sensitive to assumptions and ranged from 2504 to 18,886. Baseline WMH volume and Fazekas score predicted follow-up WMH volume. Study size was smallest using volumes and longer-term follow-up, but this must be balanced against resources required to measure volumes versus Fazekas scores, bias due to dropout and scanner drift. Samples sizes based on Fazekas scores may be best estimated with simulation studies.

14 February 2022 in Development
Verified
Journal Article
Open access
PDF file
EKElisabeth Kugler
Elisabeth Kugler
JFJames Frost
James Frost
VSVishmi Silva
Vishmi Silva
KPKaren Plant
Karen Plant
KCKarishma Chhabria
Karishma Chhabria
PAPaul Armitage
Paul Armitage
Zebrafish transgenic lines and light sheet fluorescence microscopy allow in-depth insights into three-dimensional vascular development in vivo. However, quantification of the zebrafish cerebral vasculature in 3D remains highly challenging. Here, we describe and test an image analysis workflow for 3D quantification of the total or regional zebrafish brain vasculature, called zebrafish vasculature quantification (ZVQ). It provides the first landmark- or object-based vascular inter-sample registration of the zebrafish cerebral vasculature, producing population average maps allowing rapid assessment of intra- and inter-group vascular anatomy. ZVQ also extracts a range of quantitative vascular parameters from a user-specified region of interest, including volume, surface area, density, branching points, length, radius and complexity. Application of ZVQ to 13 experimental conditions, including embryonic development, pharmacological manipulations and morpholino-induced gene knockdown, shows that ZVQ is robust, allows extraction of biologically relevant information and quantification of vascular alteration, and can provide novel insights into vascular biology. To allow dissemination, the code for quantification, a graphical user interface and workflow documentation are provided. Together, ZVQ provides the first open-source quantitative approach to assess the 3D cerebrovascular architecture in zebrafish.

11 January 2019 in Journal of Imaging
Verified
Journal Article
Open access
PDF file
EKElisabeth Kugler
Elisabeth Kugler
KPKaren Plant
Karen Plant
TCTimothy James Chico
Timothy James Chico
PAPaul Armitage
Paul Armitage
Zebrafish have become an established in vivo vertebrate model to study cardiovascular development and disease. However, most published studies of the zebrafish vascular architecture rely on subjective visual assessment, rather than objective quantification. In this paper, we used state-of-the-art light sheet fluorescence microscopy to visualize the vasculature in transgenic fluorescent reporter zebrafish. Analysis of image quality, vascular enhancement methods, and segmentation approaches were performed in the framework of the open-source software Fiji to allow dissemination and reproducibility. Here, we build on a previously developed image processing pipeline; evaluate its applicability to a wider range of data; apply and evaluate an alternative vascular enhancement method; and, finally, suggest a work-flow for successful segmentation of the embryonic zebrafish vasculature.

1 January 2017 in British Journal of Radiology
Verified
Journal Article
Closed access
PAPaul Armitage
Paul Armitage
NSNicholas Skipper
Nicholas Skipper
DCDaniel J A Connolly
Daniel J A Connolly
PGPaul D Griffiths
Paul D Griffiths
Objective:To assess the usefulness of arterial spin labelling (ASL) compared with dynamic susceptibility contrast (DSC) perfusion MRI for typical paediatric neuroimaging applications at 1.5 T.Methods:52 children (age: 4 months–17 years) with a variety of neurological disorders were scanned using three-dimensional ASL and echoplanar imaging DSC sequences. All images were reviewed by an experienced neuroradiologist; image quality was recorded as “good”, “acceptable” or “poor” and diagnostic value was noted as being “greater”, “similar” or “less” for ASL when compared with DSC.Results:ASL cerebral blood flow (CBF) images were judged to be acceptable in 89% of cases, poor in 11% of cases and good in 0% of cases, while DSC CBF images were acceptable in 88% of cases, poor in 12% of cases and good in 0% of cases. ASL images were judged to have better diagnostic value than DSC images in 28% of cases, about the same in 58% of cases and worse in 14% of cases.Conclusion:The results of this study suggest that ASL off...

1 October 2021 in Journal of Imaging
Verified
Journal Article
Open access
PDF file
ARAndrik Rampun
Andrik Rampun
DJDeborah Jarvis
Deborah Jarvis
PGPaul D. Griffiths
Paul D. Griffiths
Reyer ZwiggelaarReyer Zwiggelaar
Reyer Zwiggelaar
BSBryan Scotney
Bryan Scotney
PAPaul Armitage
Paul Armitage
In this work, we develop the Single-Input Multi-Output U-Net (SIMOU-Net), a hybrid network for foetal brain segmentation inspired by the original U-Net fused with the holistically nested edge detection (HED) network. The SIMOU-Net is similar to the original U-Net but it has a deeper architecture and takes account of the features extracted from each side output. It acts similar to an ensemble neural network, however, instead of averaging the outputs from several independently trained models, which is computationally expensive, our approach combines outputs from a single network to reduce the variance of predications and generalization errors. Experimental results using 200 normal foetal brains consisting of over 11,500 2D images produced Dice and Jaccard coefficients of 94.2 ± 5.9% and 88.7 ± 6.9%, respectively. We further tested the proposed network on 54 abnormal cases (over 3500 images) and achieved Dice and Jaccard coefficients of 91.2 ± 6.8% and 85.7 ± 6.6%, respectively.