Yu Chen

Yu Chen


Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 December 2011 in Optics Express
Verified
Journal Article
Open access
PDF file
CLChia-Pin Liang
Chia-Pin Liang
JWJeremiah Wierwille
Jeremiah Wierwille
TMThais Moreira
Thais Moreira
GSGary Schwartzbauer
Gary Schwartzbauer
MJM. Samir Jafri
M. Samir Jafri
YCYu Chen
Yu Chen
A forward-imaging needle-type optical coherence tomography (OCT) probe with Doppler OCT (DOCT) capability has the potential to solve critical challenges in interventional procedures. A case in point is stereotactic neurosurgery where probes are advanced into the brain based on predetermined coordinates. Laceration of blood vessels in front of the advancing probe is an unavoidable complication with current methods. Moreover, cerebrospinal fluid (CSF) leakage during surgery can shift the brain rendering the predetermined coordinates unreliable. In order to address these challenges, we developed a forward-imaging OCT probe (740 μm O.D.) using a gradient-index (GRIN) rod lens that can provide real-time imaging feedback for avoiding at-risk vessels (8 frames/s with 1024 A-scans per frame for OCT/DOCT dual imaging) and guiding the instrument to specific targets with 12 μm axial resolution (100 frames/s with 160 A-scans per frame for OCT imaging only). The high signal-to-background characteristic of DOCT provides exceptional sensitivity in detecting and quantifying the blood flow within the sheep brain parenchyma in real time. The OCT/DOCT dual imaging also demonstrated its capability to differentiate the vessel type (artery/vein) on rat’s femoral vessels. We also demonstrated in ex vivo human brain that the location of the tip of the OCT probe can be inferred from micro-anatomical landmarks in OCT images. These findings demonstrate the suitability of OCT guidance during stereotactic procedures in the brain and its potential for reducing the risk of cerebral hemorrhage.

11 December 2009 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
SYShuai Yuan
Shuai Yuan
CRCeleste A Roney
Celeste A Roney
JWJeremiah Wierwille
Jeremiah Wierwille
CCChao-Wei Chen
Chao-Wei Chen
BXBiying Xu
Biying Xu
YCYu Chen
Yu Chen
Optical coherence tomography (OCT) provides high-resolution, cross-sectional imaging of tissue microstructure in situ and in real time, while fluorescence molecular imaging (FMI) enables the visualization of basic molecular processes. There is a great deal of interest in combining these two modalities so that the tissue's structural and molecular information can be obtained simultaneously. This could greatly benefit biomedical applications such as detecting early diseases and monitoring therapeutic interventions. In this research, an optical system that combines OCT and FMI was developed. The system demonstrated that it could co-register en face OCT and FMI images with a 2.4 x 2.4 mm(2) field-of-view. The transverse resolutions of OCT and FMI of the system are both approximately 10 microm. Capillary tubes filled with fluorescent dye Cy 5.5 in different concentrations under a scattering medium are used as the phantom. En face OCT images of the phantoms were obtained and successfully co-registered with FMI images that were acquired simultaneously. A linear relationship between FMI intensity and dye concentration was observed. The relationship between FMI intensity and target fluorescence tube depth measured by OCT images was also observed and compared with theoretical modeling. This relationship could help in correcting reconstructed dye concentration. Imaging of colon polyps of the APC(min) mouse model is presented as an example of biological applications of this co-registered OCT/FMI system.

1 January 2011 in Tissue Engineering Part C: Methods
Verified
Journal Article
Closed access
CCChao-Wei Chen
Chao-Wei Chen
MBMartha W. Betz
Martha W. Betz
JFJohn P. Fisher
John P. Fisher
APAndrew Paek
Andrew Paek
YCYu Chen
Yu Chen
A simple porogen-leaching method to fabricate macroporous cyclic acetal hydrogel cell scaffolds is presented. Optical coherence tomography (OCT) was applied for nondestructive imaging and quantitative characterization of the scaffold structures. High-resolution OCT reveals the microstructures of the engineered tissue scaffolds in three dimensions. It also enables subsequent image processing to investigate quantitatively several key morphological design parameters for macroporous scaffolds, including the volume porosity, pore interconnectivity, and pore size. Two image-processing algorithms were adapted: three-dimensional labeling was applied to assess the interconnectivity, and erosion was applied to assess the pore size. Scaffolds with different design parameters were imaged, characterized, and compared. OCT imaging and image processing successfully discriminated scaffolds made from different formulations in terms of volume porosity, interconnectivity, and pore size. The cell viability and their spread across the scaffolds were confirmed by the fluorescence microscopy co-registered with OCT.

25 August 2009 in Optics Express
Verified
Journal Article
Closed access
PDF file
QLQian Li
Qian Li
MOMaristela L. Onozato
Maristela L. Onozato
PAPeter M. Andrews
Peter M. Andrews
CCChao-Wei Chen
Chao-Wei Chen
APAndrew Paek
Andrew Paek
YCYu Chen
Yu Chen
Optical coherence tomography (OCT) is a rapidly emerging imaging modality that can non-invasively provide cross-sectional, high-resolution images of tissue morphology in situ and in real-time. We previously demonstrated that OCT is capable of visualizing characteristic kidney anatomic structures, including blood vessels, uriniferous tubules, glomeruli, and renal capsules on a Munich–Wistar rat model. Because the viability of a donor kidney is closely correlated with its tubular morphology, and a large amount of image datasets are expected when using OCT to scan the entire kidney to provide a global assessment of its viability, it is necessary to develop automatic image analysis methods to quantify the spatially-resolved morphometric parameters such as tubular diameter to provide potential diagnostic information. In this study, we imaged the human kidney in vitro and quantified the diameters of hollow structures such as blood vessels and uriniferous tubules automatically. The microstructures were first segmented from cross-sectional OCT images. Then the spatially-isolated region-of-interest (ROI) was automatically selected to quantify its dimension. This method enables the automatic selection and quantification of spatially-resolved morphometric parameters. The quantification accuracy was validated, and measured features are in agreement with known kidney morphology. This work can enable studies to determine the clinical utility of OCT for kidney imaging, as well as studies to evaluate kidney morphology as a biomarker for assessing kidney’s viability prior to transplantation.

19 May 2009 in Optics Letters
Verified
Journal Article
Closed access
PDF file
SYShuai Yuan
Shuai Yuan
QLQian Li
Qian Li
JJJames Jiang
James Jiang
ACAlex Cable
Alex Cable
YCYu Chen
Yu Chen
We present a combined optical coherence tomography (OCT) and line-scanning fluorescence laminar optical tomography (FLOT) system. This hybrid system enables coregistered structural and molecular imaging in 3D with 10–100 μm resolution and millimeter-scale imaging depth. Experimental results on a capillary phantom with fluorescence dye Cy5.5 using an OCT/FLOT imaging system have been demonstrated.

8 December 2015 in Annals of Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
MOMehmet S. Ozturk
Mehmet S. Ozturk
CCChao-Wei Chen
Chao-Wei Chen
RJRobin Ji
Robin Ji
LZLingling Zhao
Lingling Zhao
BNBao-Ngoc B. Nguyen
Bao-Ngoc B. Nguyen
XIXavier Intes
Xavier Intes