Ahmed Fayed

Prof. Ahmed Fayed


Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2009 in Journal of Pharmaceutical and Biomedical Analysis
Verified
Journal Article
Closed access
AFAhmed Fayed
Ahmed Fayed
SWSoheir A. Weshahy
Soheir A. Weshahy
MSMostafa A. Shehata
Mostafa A. Shehata
NHNagiba Y. Hassan
Nagiba Y. Hassan
JPJochen Pauwels
Jochen Pauwels
ASAnn Van Schepdael
Ann Van Schepdael

6 December 2006 in Journal of Separation Science
Verified
Journal Article
Closed access
PDF file
AFAhmed Fayed
Ahmed Fayed
MSMostafa Abdel‐Aaty Shehata
Mostafa Abdel‐Aaty Shehata
NHNagiba Yehia Hassan
Nagiba Yehia Hassan
SESoheir Ahmed El‐Weshahy
Soheir Ahmed El‐Weshahy

5 November 2007 in Journal of Pharmaceutical and Biomedical Analysis
Verified
Journal Article
Closed access
AFAhmed Fayed
Ahmed Fayed
MSMostafa A. Shehata
Mostafa A. Shehata
AAAhmed Ashour
Ahmed Ashour
NHNagiba Y. Hassan
Nagiba Y. Hassan
SWSoheir A. Weshahy
Soheir A. Weshahy

3 June 2019 in Chemical Papers
Verified
Journal Article
Closed access
PDF file
AFAhmed Fayed
Ahmed Fayed
RYRania M. Youssif
Rania M. Youssif
NSNahla N. Salama
Nahla N. Salama
HHHassan A. Hendawy
Hassan A. Hendawy
EEEman S. Elzanfaly
Eman S. Elzanfaly

4 April 2016 in RSC Advances
Verified
Journal Article
Closed access
PDF file
AFAhmed Fayed
Ahmed Fayed
MHMaha Abdel-Monem Hegazy
Maha Abdel-Monem Hegazy
A novel high performance liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) method was established for the simultaneous determination of multivitamins, namely thiamine hydrochloride (B1), pyridoxine (B6), cyanocobalamin (B12) and benfotiamine (BEN) and their co-formulated drug, diclofenac sodium (DIC) using torsemide as internal standard (IS). Chromatographic separation was accomplished on Shimadzu LC-20 AT Series HPLC, equipped with Sunfire C18 column (Waters) (50 × 4.6 mm, 5 μm) using methanol : 0.02 M ammonium acetate (80 : 20, v/v) pH 6.0 for B1, B12, BEN and DIC, while using methanol : acetonitrile : 0.01 M ammonium formate (80 : 10 : 10, v/v/v) pH 6.25 for B6 on separate runs at a flow rate of 1.0 mL min−1. Sample preparation involves extraction with methanol using 30 ng mL−1 of IS. Electrospray ionization (ESI) source was operated in the positive ion mode. The multiple reaction monitoring (MRM) mode on a triple quadrupole mass spectrometer was used to quantify the drugs utilizing the transitions of 265.07/122.10, 170.01/152.20, 678.64/147.01, 467.18/122.10, 296.02/214.20, 348.99/263.90 (m/z) for B1, B6, B12, BEN, DIC and IS, respectively. The proposed method was effectively applied for the analysis of laboratory prepared mixtures, in spiked human plasma as well as in their combined pharmaceutical formulations. A detailed analytical and bioanalytical validation was conducted in compliance with the FDA and ICH guidelines proving the method to be selective, linear, precise and accurate over the concentration ranges of 0.01–20.00, 0.02–50.00, 15.00–500.00, 5.00–500.00 and 10.00–500.00 ng mL−1 for the five compounds, in order. The simplicity and sensitivity of this method allows its use in the quality control of the cited drugs.

7 January 2023 in Journal of Chromatographic Science
Verified
Journal Article
Closed access
MEMaya S Eissa
Maya S Eissa
EBEbraam Boushra
Ebraam Boushra
MHMaha A Hegazy
Maha A Hegazy
AFAhmed Fayed
Ahmed Fayed
Two selective stability-indicating procedures were adopted for the quantification of Solifenacin succinate (SOL) along with its acid degradant, in its powder form or in pharmaceutical tablet. Under stress conditions, the acid degradation pathway of SOL was investigated, its official impurity (SOL imp-A) was obtained as the possible acid degradation product, also. A densitometric technique based on the separation of SOL from SOL imp-A employing HPTLC plates prelaminated with silica gel 60 F254 as the stationary phase and a developing solution containing methanol:chloroform:ammonia (8:1:1, v/v/v) and UV scanning of the developed bands at 220 nm. Linear regression analysis data for the calibration plot of SOL showed perfect linear relationships throughout the range of concentration 10–60 μg/band. A reversed phase C18 analytical column (4.6 × 250 mm, 5 μm) was also used to separate the mixture at a flow rate of 1 mL/min, using acetonitrile:0.05 M phosphate buffer (70:30, v/v) as the mobile phase and phosphoric acid to set pH = 3.5. Quantification was obtained at 220 nm using peak area and linear calibration curve across a concentration range of 10–70 μg/mL. The recommended procedures were applied to the existing dosage form, and they generated satisfactory results.