Mobile crowd sensing (MCS) is an application that collects data from a network of conscientious volunteers and implements it for the common or personal benefit. This contribution proposes an implementation that collects the data from hypertensive patients, thus creating an experimental database using the cloud service Platform as a Service (PaaS). The challenge is to perform the analysis without the main diagnostic feature for hypertension—the blood pressure. The other problems consider the data reliability in an environment full of artifacts and with limited bandwidth and battery resources. In order to motivate the MCS volunteers, a feedback about the patient’s current status is created, provided by the means of machine-learning (ML) techniques. Two techniques are investigated and the Random Forest algorithm yielded the best results. The proposed platform, with slight modifications, can be adapted to the patients with other cardiovascular problems.
1 January 2017 in Computers in Biology and Medicine
The automotive industry and scientific community are making efforts to develop innovative solutions that would increase successful driver performance in preventing crashes caused by drivers’ health and concentration. High stress is one of the causes of impaired driver performance. This study investigates the ability to classify different stress levels based on capacitive electrocardiogram (cECG) recorded during driving by unobtrusive acquisition systems with different hardware implementations. The proposed machine-learning model extracted only four features, based on the detection of the R peak, which is the most reliably detected characteristic point even in inferior quality cECG. Another criterion for selecting the features is their low computational complexity, which enables real-time application. The proposed method was validated on three open data sets recorded during driving: electrocardiogram (ECG) recorded by electrodes with direct skin contact (high quality); cECG recorded without direct skin contact through clothes by electrodes built into a portable multi-modal cushion (middle quality); and cECG recorded through the clothes without direct skin contact by electrodes built into a car seat (lowest quality). The proposed model achieved a high accuracy of 100% for high-quality ECG, 96.67% for middle-quality cECG, and 98.08% for the lower-quality cECG.
Cross-approximate entropy(XApEn)quantifies the mutual orderliness of simultaneously recorded time series. Despite being derived from the firmly established solitary entropies, it has never reached their reputation and deployment. The aim of this study is to identify the problems that preclude widerXApEnimplementation and to develop a set of solutions. Exact expressions forXApEnand its constitutive parts are derived and compared to values estimated from artificial data. This comparison revealed vast regions within the parameter space that do not guarantee reliable probability estimation, makingXApEnestimates inconsistent. A simple correction to one of theXApEnprocedural steps is proposed. Three sets of formulae for joint parameter selection are derived. The first one is intended to maximize threshold profile. The remaining ones minimizeXApEninstability according to the strong and weak criteria. The derived expressions are verified using cardiovascular signals recorded from rats (long signals) and healthy volunteers (short clinical signals), proposing a change of traditional parameter guidelines.
The long-term electromagnetic field (EMF) monitoring has become an imperative task in modern EMF investigation, particularly in areas of increased sensitivity to EMF exposure. Such kind of monitoring can provide valuable information on EMF variability, as well as some additional, hidden, knowledge from its continuous measurement data series. This paper will present an approach of the EMF behavior extraction from the measurement results, based on the averaging over time. The case study of the five-year monitoring period was analyzed, in which data seta was acquired by the sensor of the Serbian EMF RATEL monitoring network, in the University of Novi Sad (UNS) campus.
This paper proposes a method that maps the coupling strength of an arbitrary number of signals D, D ≥ 2, into a single time series. It is motivated by the inability of multiscale entropy to jointly analyze more than two signals. The coupling strength is determined using the copula density defined over a [0 1]D copula domain. The copula domain is decomposed into the Voronoi regions, with volumes inversely proportional to the dependency level (coupling strength) of the observed joint signals. A stream of dependency levels, ordered in time, creates a new time series that shows the fluctuation of the signals’ coupling strength along the time axis. The composite multiscale entropy (CMSE) is then applied to three signals, systolic blood pressure (SBP), pulse interval (PI), and body temperature (tB), simultaneously recorded from rats exposed to different ambient temperatures (tA). The obtained results are consistent with the results from the classical studies, and the method itself offers more levels of freedom than the classical analysis.