The objective of this work is the study of the procedure for flow rate measurement derived from temperature profiles. This method is deemed appropriate because of the inability to mount conventional flow meters in multiple-zone oil wells. In this work, a reduced-scale prototype well with horizontal geometry was developed to study and validate a method of flow profiling by temperature measurements in the well column based on a heat transfer mathematical model studied by Ramey in 1962. Flow sensors were installed at key points to provide validation data for the flow measurements derived from the temperature. The plant was automated and all the tests were managed from a workstation. It was possible to test different situations to provide a variability of evaluation scenarios. The initial experiments used injected fluid flow rates of 15 and 18 L/min in the well inlet. The results of the calculated flow values in different work conditions were compared with a relatively low error reference meter.
In order to reduce the costs of implementing the radial position control system of a three-phase bearingless machine with split winding, this article proposes a driving method that uses only two phases of the system instead of the three-phase traditional one. It reduces from six to four the number of inverter legs, drivers, sensors, and current controllers necessary to drive and control the system. To justify the proposal, this new power and control configuration was applied to a 250 W machine controlled by a digital signal processor (DSP). The results obtained demonstrated that it is possible to carry out the radial position control through two phases, without loss of performance in relation to the conventional three-phase drive and control system.
This paper presents the development and implementation of a centralized industrial network for an automatic purified water production system used in the pharmaceutical industry. This implementation is part of a project to adapt an industrial plant to cope with advances in industrial technology to achieve the level of Industry 4.0. The adequacy of the instruments and the interconnection of the controllers made it possible to monitor the process steps by transforming a manual plant, with discontinuous production into an automated plant, improving the efficiency and quality of the produced water. The development of a supervisory system provides the operator with a panoramic view of the process, informing in real-time the behavior of the variables in the process steps, as well as storing data, event history and alarms. This system also prevented the collection of erroneous or manipulated data, making the process more transparent and reliable. Accordingly, we have been able to tailor this water treatment plant to operate within the minimum requirements required by the regulator.
This paper is presented a new approach to fuzzy active-disturbance rejection position controller of the bearingless induction machine (BIM) servo system. The paper deals with applying the Fuzzy technique of Active Disturbance Rejection Control (ADRC) in stabilizing and controlling the radial position rotor of a bearingless induction machine with split winding. A new control variable for the radial position problem is a proposition in the article, and the variable ADRC-Fuzzy control is using to improved dynamics of the closed-loop system when a load modification happens at the output. The simulation computational show that control stabilizes the plant and rejects disturbances. These results served as the basis for future experimental validation in the problem.
In this paper it is proposed the displacement control of a bearingless induction machine (BIM) with split winding and optimized drive structure using Active Disturbance Rejection Control (ADRC). Considering that the BIM is a multivariable, nonlinear, and time-varying system with coupled variables, advanced control techniques can be useful in order to make the system operate efficiently and with good dynamic performance. The ADRC considers the total disturbance, composed of unmodeled dynamics, nonlinearities, uncertainties, and load variations, as an extended state and estimates it in real-time through a state observer. This increases the overall robustness of the control system to disturbances of different natures. The application of the ADRC technique on the radial position control of the BIM used in this work showed that a Linear version of ADRC is not able to compensate for radial load disturbances but this drawback can be solved by the use of a nonlinear observer in the ADRC structure. Besides that, both control versions of the ADRC were able to make stable the naturally unstable radial displacement of the machine’s rotor.
The purpose of this paper is to perform the radial position control of a three-phase induction motor with split winding by the current control of only two phases. The third phase current is obtained by the sum of the two controlled currents. The objective is to reduce the number of components needed to drive the motor and reduce costs. This strategy was implemented in a prototype of 250 W that works in vertical position. The experimental tests showed similar results to the ones obtained with the three-phase control techniques.