Zhiquan Li

Dr. Zhiquan Li


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2018 in Optics Communications
Verified
Journal Article
Closed access
RXRuijie Xie
Ruijie Xie
ZLZhiquan Li
Zhiquan Li
XLXin Li
Xin Li
EGErdan Gu
Erdan Gu
LNLiyong Niu
Liyong Niu
XSXiaopeng Sha
Xiaopeng Sha

18 May 2020 in Plasmonics
Verified
Journal Article
Closed access
PDF file
JWJiawei Wu
Jiawei Wu
SGShiliang Guo
Shiliang Guo
ZLZhiquan Li
Zhiquan Li
XLXin Li
Xin Li
HXHan Xue
Han Xue
ZWZhiwei Wang
Zhiwei Wang

1 April 2019 in Superlattices and Microstructures
Verified
Journal Article
Closed access
XLX. Li
X. Li
RXR. Xie
R. Xie
WLW. Li
W. Li
ZLZhiquan Li
Zhiquan Li
EGE. Gu
E. Gu
SGS. Guo
S. Guo

1 November 2023 in International Journal of Fuzzy Systems
Verified
Journal Article
Closed access
PDF file
ZWZiguang Wang
Ziguang Wang
AMAiwen Meng
Aiwen Meng
Hak Keung LamHak Keung Lam
Hak Keung Lam
BXBo Xiao
Bo Xiao
ZLZhiquan Li
Zhiquan Li

12 December 2019 in Sensors
Verified
Journal Article
Open access
PDF file
WLWenchao Li
Wenchao Li
ZLZhiquan Li
Zhiquan Li
JHJiahuan He
Jiahuan He
LCLiyang Chu
Liyang Chu
In this paper, a grating-coupled surface plasmon resonance concentration sensor employing a gold and indium tin oxide (Au/ITO) nanoparticle composite instead of metal is proposed. The structure and material parameters of the sensor are discussed and analyzed. Taking the ethylene glycol concentration as an example, the influence of the nanocomposite on the wave vector matching, the influence of the refractive index of the medium to be tested and the influence of the concentration on the refractive index were analyzed in detail. The experimental results show that when the sensor is used for the measurement of ethylene glycol concentration, the correlation coefficient between the concentration and the refractive index is as high as 0.999995. The fitting curve and data correlation are good, and the sensitivity has a good linear relationship with the sensitivity. Therefore, the sensor structure proposed in this paper can be used to accurately measure the trace concentration of liquid, and its sensing mode has certain reference value for the measurement of general trace fluid concentration.

29 September 2021 in Nanomaterials
Verified
Journal Article
Open access
PDF file
SGShiliang Guo
Shiliang Guo
XLXin Li
Xin Li
ZGZechen Guo
Zechen Guo
XZXingtao Zhao
Xingtao Zhao
SMShuhan Meng
Shuhan Meng
ZLZhiquan Li
Zhiquan Li
In this paper, we propose a polarization-independent optoelectronic modulator based on the electrical absorption effect of graphene. Firstly, we use the simulation software COMSOL Multiphysics to design the structure, and find via changing the applied voltage on both ends of the graphene that the equivalent refractive index of graphene can be changed, thus changing the light absorption capacity of the modulator. The waveguides in the transverse magnetic (TM) and transverse electric (TE) modes have almost the same extinction coefficient by making a double-layer graphene ridge structure in the center of the silicon-based waveguide, which can achieve approaching modulation depth in the TM and TE modes. At 1550 nm wavelength, the two-dimensional cross-section of the structure is analyzed by the FEM method using COMSOL Multiphysics to obtain the effective refractive index of the structure. The simulation results show that when the distance between the double-layer graphene isolation layer is d = 20 nm, the TE and TM modes can achieve extinction ratios up to 110 dB over the wide communication band by selecting appropriate “ON” and “OFF” switching points. The bandwidth is 173.78 GHz and the insertion loss is only 0.0338 dB.