In the article, the method and algorithm for a control strategy of the operation of a micro combined heat and power (mCHP) unit and for reducing the power consumption peaks (peak shaving) are proposed and analyzed. Two scenarios of the mCHP’s operation, namely with and without the control strategy, are discussed. For calculation purposes, a boiler fired with wood pellets coupled with a Stirling engine, manufactured by ÖkoFEN, was used. These results were used to analyze two scenarios of the control strategy. In this study, the operation of mCHP was simulated using the energyPRO software. The application of this control strategy to dispersed mCHP systems allows for a very effective “peak shaving” in the local power grid. The results of calculation using the new algorithm show that the electricity generated by the mCHP system covers the total demand for power during the morning peak and reduces the evening peak by up to 71%. The application of this method also allows for a better reduction of the load of conventional grids, substations, and other equipment.
This paper investigates the use of a hybrid renewable heat-supply system based on photovoltaic–thermal collectors, an industrial heat pump, thermal energy storage, and electrical energy storage for a small- to medium-scale district-heating network. A dynamic lumped-parameter model was developed and applied to hourly data from an existing network. The photovoltaic–thermal collector model accounts for low-temperature operation, wind effects, precipitation, and condensation-related heat gains, while the heat pump is represented using compressor performance characteristics under variable source and sink temperatures. The analysis focuses on whether the proposed configuration can meet summer heat demand and reduce reliance on a conventional peak or backup source during shoulder periods. The results show that, during an extended non-heating season, the system can supply approximately 90–100% of the district-heating demand while maintaining a daily mean coefficient of performance in the range of approximately 2.0–3.1. The photovoltaic–thermal field and electrical energy storage do not provide full electrical self-sufficiency, but they reduce grid electricity import; in July and August, the electricity autarky coefficient is approximately 48–49%. The results indicate that the proposed system can serve as a seasonal renewable heat source for district heating. Further refinement of the configuration, operating setpoints, and control strategy could improve its shoulder-season performance.