Duanduan Chen

Prof. Dr. Duanduan Chen

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2021 in Medical Image Analysis
Verified
Journal Article
Closed access
DCDuanduan Chen
Duanduan Chen
XZXuyang Zhang
Xuyang Zhang
YMYuqian Mei
Yuqian Mei
FLFangzhou Liao
Fangzhou Liao
HXHuanming Xu
Huanming Xu
YVYiannis Ventikos
Yiannis Ventikos

1 January 2013 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
DCDuanduan Chen
Duanduan Chen
MMMatthias Müller-Eschner
Matthias Müller-Eschner
HTHendrik von Tengg-Kobligk
Hendrik von Tengg-Kobligk
DBDavid Barber
David Barber
DBDittmar Böckler
Dittmar Böckler
YVYiannis Ventikos
Yiannis Ventikos
Aortic dissection is a severe pathological condition in which blood penetrates between layers of the aortic wall and creates a duplicate channel – the false lumen. This considerable change on the aortic morphology alters hemodynamic features dramatically and, in the case of rupture, induces markedly high rates of morbidity and mortality. In this study, we establish a patient-specific computational model and simulate the pulsatile blood flow within the dissected aorta. The k-ω SST turbulence model is employed to represent the flow and finite volume method is applied for numerical solutions. Our emphasis is on flow exchange between true and false lumen during the cardiac cycle and on quantifying the flow across specific passages. Loading distributions including pressure and wall shear stress have also been investigated and results of direct simulations are compared with solutions employing appropriate turbulence models. Our results indicate that (i) high velocities occur at the periphery of the entries; (ii) for the case studied, approximately 40% of the blood flow passes the false lumen during a heartbeat cycle; (iii) higher pressures are found at the outer wall of the dissection, which may induce further dilation of the pseudo-lumen; (iv) highest wall shear stresses occur around the entries, perhaps indicating the vulnerability of this region to further splitting; and (v) laminar simulations with adequately fine mesh resolutions, especially refined near the walls, can capture similar flow patterns to the (coarser mesh) turbulent results, although the absolute magnitudes computed are in general smaller. The patient-specific model of aortic dissection provides detailed flow information of blood transport within the true and false lumen and quantifies the loading distributions over the aorta and dissection walls. This contributes to evaluating potential thrombotic behavior in the false lumen and is pivotal in guiding endovascular intervention. Moreover, as a computational study, mesh requirements to successfully evaluate the hemodynamic parameters have been proposed.

1 August 2021 in The Journal of Thoracic and Cardiovascular Surgery
Verified
Journal Article
Closed access
HXHuanming Xu
Huanming Xu
JXJiang Xiong
Jiang Xiong
XHXiaofeng Han
Xiaofeng Han
YMYuqian Mei
Yuqian Mei
YSYue Shi
Yue Shi
DCDuanduan Chen
Duanduan Chen

7 September 2017 in Medical Engineering & Physics
Verified
Journal Article
Open access
HXHuanming Xu
Huanming Xu
ZLZhenfeng Li
Zhenfeng Li
HDHuiwu Dong
Huiwu Dong
YZYilun Zhang
Yilun Zhang
JWJianyong Wei
Jianyong Wei
JXJiang Xiong
Jiang Xiong
Thoracic endovascular aortic repair (TEVAR) is commonly applied in type-B aortic dissection. For patients with dissection affects descending aorta and extends downward to involve abdominal aorta and possibly iliac arteries, false lumen (FL) expansion might occur post-TEVAR. Predictions of dissection development may assist in medical decision on re-intervention or surgery. In this study, two patients are selected with similar morphological features at initial presentation but with different long-term FL development post-TEVAR (stable and enlarged FL). Patient-specific models are established for each of the follow-ups. Flow boundaries and computational validations are obtained from Doppler ultrasound velocimetry. By analyzing the hemodynamic parameters, the false-to-true luminal pressure difference (PDiff) and particle relative residence time (RRT) are found related to FL remodeling. It is found that (i) the position of the first FL flow entry is the watershed of negative-and-positive PDiff and, in long-term follow-ups, and the position of largest PDiff is consistent with that of the greatest increase of FL width; (ii) high RRT occurs at the FL proximal tip and similar magnitude of RRT is found in both stable and enlarged cases; (iii) comparing to the RRT at 7days post-TEVAR, an increase of RRT afterwards in short-term is found in the stable case while a slight decrease of this parameter is found in the enlarged case, indicating that the variation of RRT in short-term post-TEVAR might be potential to predict long-term FL remodeling.

11 October 2018 in Sensors
Verified
Journal Article
Open access
PDF file
GPG.Y. Pei
G.Y. Pei
JWJinglong Wu
Jinglong Wu
DCDuanduan Chen
Duanduan Chen
GGGuoxin Guo
Guoxin Guo
SLShuozhen Liu
Shuozhen Liu
Tianyi YanTianyi Yan
Tianyi Yan
Electroencephalogram (EEG) neurofeedback improves cognitive capacity and behaviors by regulating brain activity, which can lead to cognitive enhancement in healthy people and better rehabilitation in patients. The increased use of EEG neurofeedback highlights the urgent need to reduce the discomfort and preparation time and increase the stability and simplicity of the system’s operation. Based on brain-computer interface technology and a multithreading design, we describe a neurofeedback system with an integrated design that incorporates wearable, multichannel, dry electrode EEG acquisition equipment and cognitive function assessment. Then, we evaluated the effectiveness of the system in a single-blind control experiment in healthy people, who increased the alpha frequency band power in a neurofeedback protocol. We found that upregulation of the alpha power density improved working memory following short-term training (only five training sessions in a week), while the attention network regulation may be related to other frequency band activities, such as theta and beta. Our integrated system will be an effective neurofeedback training and cognitive function assessment system for personal and clinical use.

1 December 2021 in Journal of Biomechanics
Verified
Journal Article
Open access
CSCatriona Stokes
Catriona Stokes
MBMirko Bonfanti
Mirko Bonfanti
ZLZeyan Li
Zeyan Li
JXJiang Xiong
Jiang Xiong
DCDuanduan Chen
Duanduan Chen
VDVanessa Díaz-Zuccarini
Vanessa Díaz-Zuccarini
We present a novel, cost-efficient methodology to simulate aortic haemodynamics in a patient-specific, compliant aorta using an MRI data fusion process. Based on a previously-developed Moving Boundary Method, this technique circumvents the high computational cost and numerous structural modelling assumptions required by traditional Fluid-Structure Interaction techniques. Without the need for Computed Tomography (CT) data, the MRI images required to construct the simulation can be obtained during a single imaging session. Black Blood MR Angiography and 2D Cine-MRI data were used to reconstruct the luminal geometry and calibrate wall movement specifically to each region of the aorta. 4D-Flow MRI and non-invasive pressure measurements informed patient-specific inlet and outlet boundary conditions. Luminal area closely matched 2D Cine-MRI measurements with a mean error of less than 4.6% across the cardiac cycle, while physiological pressure and flow distributions were simulated to within 3.3% of patient-specific targets. Moderate agreement with 4D-Flow MRI velocity data was observed. Despite lower peak velocity, an equivalent rigid-wall simulation predicted a mean Time-Averaged Wall Shear Stress (TAWSS) 13% higher than the compliant simulation. The agreement observed between compliant simulation results and MRI data is testament to the accuracy and efficiency of this MRI-based simulation technique.