Aims Electrocardiographic diagnosis of wide QRS complex tachycardia (WCT) continues to be challenging as none one of the available methods is specific for ventricular tachycardia (VT) diagnosis. We aimed to construct a method for WCT differentiation based on a scoring system, in which ECGs are graded according to the number of VT-specific features. This novel method was validated and compared with Brugada algorithm and other methods. Methods and results A total of 786 WCTs (512 VTs) from 587 consecutive patients with a proven diagnosis were analysed by two blinded observers. The VT score method was based on seven ECG features: initial R wave in V1, initial r > 40 ms in V1/V2, notched S in V1, initial R in aVR, lead II R wave peak time ≥50 ms, no RS in V1-V6, and atrioventricular dissociation. Atrioventricular dissociation was assigned two points, and each of the other features was assigned one point. The overall accuracy of VT score ≥1 for VT diagnosis (83%) was higher than that of the aVR (72%, P = 0.001) and Brugada (81%) algorithms. Ventricular tachycardia score ≥3 was present in 66% of VTs and was more specific (99.6%) than any other algorithm/criterion for VT diagnosis. Ventricular tachycardia score ≥4 was present in 33% of VTs and was 100% specific for VT. Conclusion The new ECG-based method provides a certain diagnosis of VT in the majority of patients with VT, identifies unequivocal ECGs, and has superior overall diagnostic accuracy to other ECG methods.
1 June 2014 in The American Journal of Emergency Medicine
To investigate the effect of implantation-related characteristics, especially lead position and left ventricular (LV)-paced QRS morphology, on long-term mortality and morbidity in cardiac resynchronization therapy (CRT) patients. The study retrospectively analysed 362 consecutive patients who underwent CRT device implantation over a 6 year period. Pre-implantation, LV-only paced, and biventricularly paced 12-lead electrocardiograms were obtained. Left ventricular and right ventricular (RV) lead positions were determined using biplane fluoroscopy and roentgenograms. The Kaplan–Meier method was used to estimate the survival function for all-cause death/hospitalization and cardiovascular death/hospitalization. Univariate and multivariate Cox proportional hazards models were also applied. The mean follow-up time was 24.7 ± 16.9 months. There were 79 deaths (62 cardiovascular) and 99 unplanned hospitalizations (72 cardiovascular). One year and 2 year all-cause mortality rates were 8.5 and 18.0%, respectively. Electrocardiographic and fluoroscopic descriptors of the LV lead position were found to be predictors of mortality/morbidity (as were functional class, heart failure aetiology, hyponatremia, and chronic atrial fibrillation). In particular, the antero-apical pattern of LV-only paced QRS showed a hazard ratio (HR) of 1.8 in univariate and 1.7 in multivariate analysis for predicting all-cause death/hospitalization (P = 0.006). The apical/paraseptal LV lead position showed an HR of 2.1 in univariate and 1.9 in multivariate analysis for predicting cardiovascular death/hospitalization (P = 0.018). To achieve better long-term outcomes in CRT patients the antero-apical pattern of LV QRS complexes and apical or paraseptal LV lead position should be avoided.