Techniques for residential energy monitoring are an emerging field that is currently drawing significant attention. This paper is a description of the current efforts to monitor and compare the performance of three solar powered homes built at Missouri University of Science and Technology. The homes are outfitted with an array of sensors and a data logger system to measure and record electricity production, system energy use, internal home temperature and humidity, hot water production, and exterior ambient conditions the houses are experiencing. Data is being collected to measure the performance of the houses, compare to energy modeling programs, design and develop cost effective sensor systems for energy monitoring, and produce a cost effective home control system.
This paper presents the findings from an undergraduate research project concerning the energy efficiency, consumption, and generation of a 1000 ft2 (92.9 m2) solar house. The results were compared to a home of similar size and layout, built using traditional construction methods. The solar house was modeled after the Chameleon House: Missouri University of Science and Technology’s 2013 entry in the U.S. Department of Energy Solar Decathlon. The efficiency of the design was analyzed using Energy-10 Version 1.8 software. For this comparison, a fictional American couple was created and a breakdown of their energy-use habits was recorded to accurately depict the magnitude of energy consumption. A 71% energy savings was forecasted using the Energy-10 software through the incorporation of various energy-conserving strategies in the home’s design. In addition, if a 9.1 kW photovoltaic array is also installed on a home of this size, it is possible to fully offset the energy consumption of the home. The forecasted energy usage and production detailed in this report shall be used for analyzing the integrity of the design of the Chameleon House as well as future solar houses constructed by the Missouri S&T Solar House Team.
The main goal of this research was to develop and understand the performance of a hybrid roof system that combined an amorphous junction photovoltaic panel in combination with copper panel and tubing encased in a low-iron glass. The setup encompassed 160 sq ft of the solar thermal electric panel (STEP) system supplied with a glycol-water closed-loop system. The system was fixed to a simulated roof assembly built at the optimal angle of 61° for winter solstice for the local area (Rolla, Missouri). The encased combination panel provided consistent electrical efficiency and mixed thermal efficiencies based on the hours of operation. In conclusion this paper will discuss experimental performance analysis on the STEP system thermal and overall outcomes. Further testing on the effects of a glazed versus unglazed panel yielded a 23% reduction in solar electric production; however, it increased thermal collection by approximately 200%. The present study shows that the idea of a STEP system is viable. A pr...
A experimental study was conducted to examine the shear and tensile strength of pneumatically driven pin connections used in cold-formed steel construction. This study included the key parameters that influence the connection strength: steel thickness (16-, 18- and 20-gauge steel), sheathing thickness (1/2 in. (152-mm) Unipan and 1/2 in. (152-mm) Dens-Glass Gold). The shear design values given in the AISI design specifications for screw connections are compared with those obtained from a series of lap shear tests and a good agreement is obtained. Initial analysis of the AISI design equation for tensile failure due to pull-over yielded poor results when compared to the withdrawal test values. Upon further analysis it was determined the connection failed in punch shear mode and the results compared well with the ACI punch shear analysis. The equations developed in this study can be used to predict the strength of pneumatically driven pin connections in cold-formed steel construction.
1 June 2010 in Journal of Architectural Engineering
Missouri University of Science and Technology (formerly, the University of Missouri-Rolla) began a Bachelor of Science degree program in architectural engineering in the fall of 2002. The 4-year academic program’s curriculum at Missouri S&T requires the students to complete 128 semester credit hours during a period of eight semesters, with options for technical electives in one of four focus areas: structural engineering, construction engineering and project management, environmental systems for buildings, and construction materials. This paper presents the architectural engineering curriculum at Missouri S&T. It discusses the objectives of the curriculum, the constraints upon its structure, along with challenges that faced the establishment of an architectural engineering program.
Team Missouri’s 2009 Solar Decathlon entry featured a revolutionary home automation system, Chameleon, promoting both convenience and energy savings. This was accomplished using the typical controls of a convenience based automation system, while maintaining user set points, such as a home’s ambient temperature, in the most energy efficient manner. Environmental features of the system include controls for home heating, ventilation and air conditioning, lighting, windows, shades, appliances, indoor air quality, as well as indoor and outdoor irrigation. Further analysis and refinement to the prototype system displayed at the competition is also presented in this paper.