Stefanie Corradini

Dr. Stefanie Corradini

Department of Radiation Oncology, LMU Munich, 81377 Munich, Germany
orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 June 2019 in Radiation Oncology
Verified
Journal Article
Open access
PDF file
SCStefanie Corradini
Stefanie Corradini
Filippo AlongiFilippo Alongi
Filippo Alongi
NAN. Andratschke
N. Andratschke
CBC. Belka
C. Belka
LBLuca Boldrini
Luca Boldrini
MNMaximilian Niyazi
Maximilian Niyazi
Magnetic Resonance-guided radiotherapy (MRgRT) marks the beginning of a new era. MR is a versatile and suitable imaging modality for radiotherapy, as it enables direct visualization of the tumor and the surrounding organs at risk. Moreover, MRgRT provides real-time imaging to characterize and eventually track anatomical motion. Nevertheless, the successful translation of new technologies into clinical practice remains challenging. To date, the initial availability of next-generation hybrid MR-linac (MRL) systems is still limited and therefore, the focus of the present preview was on the initial applicability in current clinical practice and on future perspectives of this new technology for different treatment sites. MRgRT can be considered a groundbreaking new technology that is capable of creating new perspectives towards an individualized, patient-oriented planning and treatment approach, especially due to the ability to use daily online adaptation strategies. Furthermore, MRL systems overcome the limitations of conventional image-guided radiotherapy, especially in soft tissue, where target and organs at risk need accurate definition. Nevertheless, some concerns remain regarding the additional time needed to re-optimize dose distributions online, the reliability of the gating and tracking procedures and the interpretation of functional MR imaging markers and their potential changes during the course of treatment. Due to its continuous technological improvement and rapid clinical large-scale application in several anatomical settings, further studies may confirm the potential disruptive role of MRgRT in the evolving oncological environment.

12 August 2020 in European Journal of Medical Research
Verified
Journal Article
Open access
PDF file
Christiane MatuschekChristiane Matuschek
Christiane Matuschek
FMFriedrich Moll
Friedrich Moll
HFHeiner Fangerau
Heiner Fangerau
JFJohannes Christian Fischer
Johannes Christian Fischer
KZKurt Zänker
Kurt Zänker
JHJan Haussmann
Jan Haussmann
Background: The German government has made it mandatory to wear respiratory masks covering mouth and nose (MNC) as an effective strategy to fight SARS-CoV-2 infections. In many countries, this directive has been extended on shopping malls or public transportation. The aim of this paper is to critically analyze the statutory regulation to wear protective masks during the COVID-19 crisis from a medical standpoint.Methods: We performed an extensive query of the most recent publications addressing the prevention of viral infections including the use of face masks in the community as a method to prevent the spread of the infection. We addressed the issues of practicability, professional use, and acceptability based on the community and the environment where the user resided.Results: Upon our critical review of the available literature, we found only weak evidence for wearing a face mask as an efficient hygienic tool to prevent the spread of a viral infection. However, the use of MNC seems to be linked to relevant protection during close contact scenarios by limiting pathogen-containing aerosol and liquid droplet dissemination. Importantly, we found evidence for significant respiratory compromise in patients with severe obstructive pulmonary disease, secondary to the development of hypercapnia. This could also happen in patients with lung infections, with or without SARS-CoV-2.Conclusion: Epidemiologists currently emphasize that wearing MNC will effectively interrupt airborne infections in the community. The government and the politicians have followed these recommendations and used them to both advise and, in some cases, mandate the general population to wear MNC in public locations. Overall, the results seem to suggest that there are some clinically relevant scenarios where the use of MNC necessitates more defined recommendations. Our critical evaluation of the literature both highlights the protective effects of certain types of face masks in defined risk groups, and emphasizes their potential risks.

30 March 2020 in Radiation Oncology
Verified
Journal Article
Open access
PDF file
JHJan Haussmann
Jan Haussmann
SCStefanie Corradini
Stefanie Corradini
CNCarolin Nestle-Kraemling
Carolin Nestle-Kraemling
EBEdwin Bölke
Edwin Bölke
FNFreddy Joel Djiepmo Njanang
Freddy Joel Djiepmo Njanang
Christiane MatuschekChristiane Matuschek
Christiane Matuschek
Radiation therapy is an integral part of the multidisciplinary management of breast cancer. Regional lymph node irradiation in younger trials seems to provide superior target coverage as well as a reduction in long-term toxicity resulting in a small benefit in the overall survival rate. For partial breast irradiation there are now two large trials available which support the role of partial breast irradiation in low risk breast cancer patients. Multiple randomized trials have established that a sequentially applied dose to the tumor bed improves local control with the cost of worse cosmetic results.

5 March 2018 in Radiation Oncology
Verified
Journal Article
Open access
PDF file
RRRuggero Ruggieri
Ruggero Ruggieri
SNStefania Naccarato
Stefania Naccarato
RMRosario Mazzola
Rosario Mazzola
FRFrancesco Ricchetti
Francesco Ricchetti
SCStefanie Corradini
Stefanie Corradini
FAFilippo Alongi
Filippo Alongi
Linac-based stereotactic radiosurgery or fractionated stereotactic radiotherapy (SRS/FSRT) of multiple brain lesions using volumetric modulated arc therapy (VMAT) is typically performed by a multiple-isocenter approach, i.e. one isocenter per lesion, which is time-demanding for the need of independent setup verifications of each isocenter. Here, we present our initial experience with a new dedicated mono-isocenter technique with multiple non-coplanar arcs (HyperArc™, Varian Inc.) in terms of a plan comparison with a multiple-isocenter VMAT approach. From August 2017 to October 2017, 20 patients with multiple brain metastases (mean 5, range 2–10) have been treated by HyperArc in 1–3 fractions. The prescribed doses (Dp) were 18–25 Gy in single-fraction, and 21–27 Gy in three-fractions. Planning Target Volume (PTV), defined by a 2 mm isotropic margin from each lesion, had mean dimension of 9.6 cm3 (range 0.5–27.9 cm3). Mono-isocenter HyperArc VMAT plans (HA) with 5 non-coplanar 180°-arcs (couch at 0°, ±45°, ±90°) were generated and compared to multiple-isocenter VMAT plans (RA) with 2 coplanar 360°-arcs per isocenter. A dose normalization of 100%Dp at 98%PTV was adopted, while D2%(PTV) < 150%Dp was accepted. All plans had to respect the constraints on maximum dose to the brainstem (D0.5cm3 < 18 Gy) as well as to the optical nerves/chiasm, eyes and lenses (D0.5cm3 < 15 Gy). HA and RA plans were compared in terms of dose-volume metrics, by Paddick conformity (CI) and gradient (GI) index and by V12 and mean dose to the brain-minus-PTV, and in terms of MU and overall treatment time (OTT) per fraction. OTT was measured for HA treatments, whereas for RA plans OTT was estimated by assuming 3 min. For initial patient setup plus 5 min. For each CBCT-guided setup correction per isocenter. Significant variations in favour of HA plans were computed for both target dose indexes, CI (p < .01) and GI (p < .01). The lower GI in HA plans was the likely cause of the significant reduction in V12 to the brain-minus-PTV (p = .023). Although at low doses, below 2–5 Gy, the sparing of the brain-minus-PTV was in favour of RA plans, no significant difference in terms of mean doses to the brain-minus-PTV was observed between the two groups (p = .31). Finally, both MU (p < .01) and OTT (p < .01) were significantly reduced by HyperArc plans. For linac-based SRS/FSRT of multiple brain lesions, HyperArc plans assured a higher CI and a lower GI than standard multiple-isocenter VMAT plans. This is consistent with the computed reduction in V12 to the brain-minus-PTV. Finally, HyperArc treatments were completed within a typical 20 min. time slot, with a significant time reduction with respect to the expected duration of multiple-isocenters VMAT.

26 October 2016 in Radiation Oncology
Verified
Journal Article
Open access
PDF file
SSS. Schönecker
S. Schönecker
FWF. Walter
F. Walter
PFP. Freislederer
P. Freislederer
CMC. Marisch
C. Marisch
HSH. Scheithauer
H. Scheithauer
CBC. Belka
C. Belka
There is a potential for adverse cardiovascular effects in long-term breast cancer survivors following adjuvant radiotherapy (RT). For this purpose, the deep inspiration breath-hold technique (DIBH) has been introduced into clinical practice, to maximally reduce the radiation dose to the heart. However, there are a variety of DIBH delivery techniques, patient positioning and visual patient feedback mechanisms. The aim of the present study was to evaluate the application of radiotherapy in DIBH using the CatalystTM/SentinelTM system, with a special emphasis on treatment planning and dosimetric plan comparison in free breathing (FB) and DIBH. A total of 13 patients with left-sided breast cancer following breast conserving surgery were included in this prospective clinical trial. For treatment application the CatalystTM/SentinelTM system (C-RAD AB, Uppsala, Sweden) was used and gating control was performed by an audio-visual patient feedback system. CT and surface data were acquired in FB and DIBH and dual treatment plans were created using Pencil Beam and Collapsed Cone Convolution. Dosimetric output parameters of organs at risk were compared using Wilcoxon signed-rank test. Central lung distance (CLD) was retrieved from iViewTM portal images during treatment delivery. The system contains a laser surface scanner (SentinelTM) and an optical surface scanner (CatalystTM) interconnected to the LINAC systems via a gating interface and allows for a continuous and touchless surface scanning. Overall, 225 treatment fractions with audio-visual guidance were completed without any substantial difficulties. Following initial patient training and treatment setup, radiotherapy in DIBH with the CatalystTM/SentinelTM system was time-efficient and reliable. Following dual treatment planning for all patients, nine of 13 patients were treated in DIBH. In these patients, the reduction of the mean heart dose for DIBH compared to FB was 52 % (2.73 to 1.31 Gy; p = 0.011). The maximum doses to the heart and LAD were reduced by 59 % (47.90 to 19.74 Gy; p = 0.008) and 75 % (38.55 to 9.66 Gy; p = 0.008), respectively. In six of the nine patients the heart completely moved out of the treatment field by DIBH. The standard deviation of the CLD varied between 0.12 and 0.29 cm (mean: 0.16 cm). The CatalystTM/SentinelTM system enabled a fast and reliable application and surveillance of DIBH in daily clinical routine. Furthermore, the present data show that using the DIBH technique during RT could significantly reduce high dose areas and mean doses to the heart. DRKS: DRKS00010929 registered on 5. August 2016.

31 January 2019 in Cancers
Verified
Journal Article
Open access
PDF file
SCStefanie Corradini
Stefanie Corradini
DRDaniel Reitz
Daniel Reitz
MPMontserrat Pazos
Montserrat Pazos
SSStephan Schönecker
Stephan Schönecker
MBMichael Braun
Michael Braun
CBClaus Belka
Claus Belka
Although the organ preservation strategy by breast-conserving surgery (BCS) followed by radiation therapy (BCT) has revolutionized the treatment approach of early stage breast cancer (BC), the choice between treatment options in this setting can still vary according to patient preferences. The aim of the present study was to compare the oncological outcome of mastectomy versus breast-conserving therapy in patients treated in a modern clinical setting outside of clinical trials. 7565 women diagnosed with early invasive BC (pT1/2pN0/1) between 1998 and 2014 were included in this study (median follow-up: 95.2 months). In order to reduce selection bias and confounding, a subgroup analysis of a matched 1:1 case-control cohort consisting of 1802 patients was performed (median follow-up 109.4 months). After adjusting for age, tumor characteristics and therapies, multivariable analysis for local recurrence-free survival identified BCT as an independent predictor for improved local control (hazard ratio [HR]:1.517; 95%confidence interval:1.092–2.108, p = 0.013) as compared to mastectomy alone in the matched cohort. Ten-year cumulative incidence (CI) of lymph node recurrences was 2.0% following BCT, compared to 5.8% in patients receiving mastectomy (p < 0.001). Similarly, 10-year distant-metastasis-free survival (89.4% vs. 85.5%, p = 0.013) was impaired in patients undergoing mastectomy alone. This translated into improved survival in patients treated with BCT (10-year overall survival (OS) estimates 85.3% vs. 79.3%, p < 0.001), which was also significant on multivariable analysis (p = 0.011). In conclusion, the present study showed that patients treated with BCS followed by radiotherapy had an improved outcome compared to radical mastectomy alone. Specifically, local control, distant control, and overall survival were significantly better using the conservative approach. Thus, as a result of the present study, physicians should encourage patients to receive BCS with radiotherapy rather than mastectomy, whenever it is medically feasible and appropriate.