We report an open cavity, cantilever-based fiber optic Fabry–Perot interferometer hydrophone. The hydrophone is made of fused silica material, and its micro-cantilever beam is directly fabricated by femtosecond (fs) laser micromachining. The theoretical analyses and experimental verifications of the frequency response of the sensor are presented.
This paper describes a distributed sensing concept using coaxial cable-based Fabry-Perot interferometers (CCFPIs). Multiple reflectors are implemented along a coaxial cable, where every two consecutive reflectors can be considered as a low finesse CCFPI, which has a relatively weak reflection coefficient and insertion loss. The interferogram in a frequency domain of each individual CCFPI could be reconstructed through the proposed signal processing method, so that the phase detection could be applied to any CCFPIs on one cable to achieve high measurement accuracy. A large capacity sensor network with a relatively high measurement accuracy can be implemented simultaneously. The concept takes advantage of the time-domain multiplexing method and the pure frequency domain measurement, which is herein called a joint-time-frequency demodulation technique. Due to its effectiveness and robustness, the device is especially attractive for structural, downhole, or underwater applications.
This paper presents a new optical fiber distributed sensing concept based on coherent microwave-photonics interferometry (CMPI), which uses a microwave modulated coherent light source to interrogate cascaded interferometers for distributed measurement. By scanning the microwave frequencies, the complex microwave spectrum is obtained and converted to time domain signals at known locations by complex Fourier transform. The amplitudes of these time domain pulses are a function of the optical path differences (OPDs) of the distributed interferometers. Cascaded fiber Fabry-Perot interferometers (FPIs) fabricated by femtosecond laser micromachining were used to demonstrate the concept. The experimental results indicated that the strain measurement resolution can be better than 0.6 µε using a FPI with a cavity length of 1.5 cm. Further improvement of the strain resolution to the nε level is achievable by increasing the cavity length of the FPI to over 1m. The tradeoff between the sensitivity and dynamic range was also analyzed in detail. To minimize the optical power instability (either from the light source or the fiber loss) induced errors, a single reflector was added in front of an individual FPI as an optical power reference for the purpose of compensation.