A novel electrochemical aptasensor for the sensitive detection of penicillin, using a penicillin aptamer as a specific recognition element and a composite film of magnetic GR–Fe 3 O 4 NPs and PEDOT–AuNPs as the platform.
A simple electrochemical sensor based on a novel composite film consisting of multi-walled carbon nanotubes (MWCNTs), a room temperature ionic liquid (RTIL) of 1-butyl-3-methylimidazolium hexafluorophosphate (BMIMPF6), and amino functionalized graphene (GR–CO–NH–CH2–CH2–NH2) was constructed for the detection of kanamycin. Firstly, MWCNTs–BMIMPF6 composites were fabricated on the surface of a glass carbon electrode (GCE). The synergy mechanism between the MWCNTs and RTIL has been discussed. Secondly, GR–CO–NH–CH2–CH2–NH2 was modified on the first film, which could greatly improve the conductivity of the electrode. The structure of the resultant graphene oxide (GO) was confirmed by FTIR and SEM. The properties of the aptasensor were characterized by electrochemical methods. Under the optimum conditions, the electrochemical aptasensor exhibited a wide linear range for kanamycin from 0.001 to 100 μM with a low limit of detection of 0.87 nM (S/N = 3). The as-prepared aptasensor showed high sensitivity, reproducibility and stability. Finally, the proposed electrochemical aptasensor was successfully applied for the detection of kanamycin in a real sample.
A label free electrochemical sensor based on pure titanium oxide and manganese (Mn)-doped titanium oxide (TiO2) nanoparticles are fabricated and characterized for the sensitive detection of myoglobin (Mb) levels to analyze the cardiovascular infarction. Pristine and Mn-doped TiO2 nanoparticles were synthesized via the sol-gel method and characterized in order to understand their structure, morphologies, composition and optical properties. The structural properties revealed that the pure- and doped-TiO2 nanoparticles possess different TiO2 planes. FTIR studies confirm the formation of metal oxide nanoparticles by exhibiting a well-defined peak in the range of 600–650 cm−1. The values of the optical band gap, estimated from UV-Vis spectroscopy, are decreased for the Mn-doped TiO2 nanoparticles. UV-Vis spectra in the presence of myoglobin (Mb) indicated interaction between the TiO2 nanoparticles and myoglobin. The SPE electrodes were then fabricated by printing powder film over the working electrode and tested for label-free electrochemical detection of myoglobin (Mb) in the concentration range of 0–15 nM Mb. The fabricated electrochemical sensor exhibited a high sensitivity of 100.40 μA-cm−2/nM with a lowest detection limit of 0.013 nM (0.22 ng/mL) and a response time of ≤10 ms for sample S3. An interference study with cyt-c and Human Serum Albumin (HSA) of the sensors show the selective response towards Mb in 1:1 mixture.
In this paper, a convenient electrochemical aptasensor for sensitive and selective determination of streptomycin antibiotic was constructed. Signal amplification strategy of the aptasensor was achieved by utilizing porous carbon nanorods, gold nanoparticles and copper oxide functionalized multiwalled carbon nanotube composites as biosensing substrates. Porous carbon nanorods were adopted in our strategy as the core conductive material for signal amplification. The multiwalled carbon nanotube–copper oxide–gold nanoparticle nanocomposites combined the advantages of their components, which not only promote electron transfer, but also provide abundant binding sites for the immobilization of biomolecules. The streptomycin aptamer was immobilized on the nanocomposites' surface via the strong bonding interaction between the gold nanoparticles and the thiol group to generate a referenced differential pulse voltammetry signal, Iaptamer. Then, the streptomycin was immobilized on the aptasensor via the specific interaction between the aptamer and streptomycin to generate the attenuated signal, Istreptomycin. Under the optimized conditions, the changes in the signals were linear with the concentration of streptomycin in the range of 0.05–300 ng mL−1 with a low detection limit of 0.036 ng mL−1 when “ΔI = Iaptamer − Istreptomycin was used as the response signal for quantitative determination of streptomycin. In addition, the electrochemical aptasensor was also successfully applied to the determination of streptomycin in milk and honey samples. This highly sensitive electrochemical aptasensor is of great practical importance in food safety and could be widely extended to the detection of other antibiotics by replacing the sequence of the aptamer.