Endre Nagy

Prof. Dr. Endre Nagy

Research Institute of Biomolecular and Chemical Engineering, University of Pannonia, Veszprém
orcid

Research Focus & Metrics

Academic Career Length

46Years (1981-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2015 in Chemical Engineering and Processing - Process Intensification
Verified
Journal Article
Closed access
Endre NagyEndre Nagy
Endre Nagy
PMPéter Mizsey
Péter Mizsey
JHJenő Hancsók
Jenő Hancsók
Stanislav BoldyryevStanislav Boldyryev
Stanislav Boldyryev
Petar Sabev VarbanovPetar Sabev Varbanov
Petar Sabev Varbanov

1 April 2005 in Journal of Membrane Science
Verified
Journal Article
Closed access
PHP. Hadik
P. Hadik
LSL.-P. Szabó
L.-P. Szabó
Endre NagyEndre Nagy
Endre Nagy
ZFZs. Farkas
Zs. Farkas

14 February 2021 in Membranes
Verified
Journal Article
Open access
PDF file
Endre NagyEndre Nagy
Endre Nagy
Imre HegedusImre Hegedus
Imre Hegedus
DRDanyal Rehman
Danyal Rehman
QWQuantum J. Wei
Quantum J. Wei
YAYvana D. Ahdab
Yvana D. Ahdab
JLJohn H. Lienhard
John H. Lienhard
The widely used van ’t Hoff linear relation for predicting the osmotic pressure of NaCl solutions may result in errors in the evaluation of key system parameters, which depend on osmotic pressure, in pressure-retarded osmosis and forward osmosis. In this paper, the linear van ’t Hoff approach is compared to the solutions using OLI Stream Analyzer, which gives the real osmotic pressure values. Various dilutions of NaCl solutions, including the lower solute concentrations typical of river water, are considered. Our results indicate that the disparity in the predicted osmotic pressure of the two considered methods can reach 30%, depending on the solute concentration, while that in the predicted power density can exceed over 50%. New experimental results are obtained for NanoH2O and Porifera membranes, and theoretical equations are also developed. Results show that discrepancies arise when using the van ’t Hoff equation, compared to the OLI method. At higher NaCl concentrations (C > 1.5 M), the deviation between the linear approach and the real values increases gradually, likely indicative of a larger error in van ’t Hoff predictions. The difference in structural parameter values predicted by the two evaluation methods is also significant; it can exceed the typical 50–70% range, depending on the operating conditions. We find that the external mass transfer coefficients should be considered in the evaluation of the structural parameter in order to avoid overestimating its value. Consequently, measured water flux and predicted structural parameter values from our own and literature measurements are recalculated with the OLI software to account for external mass transfer coefficients.

22 July 2009 in Desalination
Verified
Journal Article
Closed access
Endre NagyEndre Nagy
Endre Nagy
EKEdina Kulcsár
Edina Kulcsár

15 February 2005 in Separation and Purification Technology
Verified
Journal Article
Closed access
PHPéter Hadik
Péter Hadik
LKLeventéné Kotsis
Leventéné Kotsis
MEMargit Eniszné-Bódogh
Margit Eniszné-Bódogh
LSLujza-P. Szabó
Lujza-P. Szabó
Endre NagyEndre Nagy
Endre Nagy

27 March 2009 in Asia-Pacific Journal of Chemical Engineering
Verified
Journal Article
Closed access
PDF file
Endre NagyEndre Nagy
Endre Nagy