This paper presents a plain strain analytical model, based on the elasticity theory, to determine the confining pressures of transverse reinforcements on the concrete core of a reinforced concrete member. The analytical evaluation of the confining pressures was first carried out on reinforced sections with square and circular stirrups, and subsequently on reinforcement configurations of greater complexity with square and rectangular stirrups and supplementary cross ties. Finally, the model has been used to evaluate the confining pressures applied by external wrapping in any material [fiber-reinforced polymer (FRP), S-glass, steel, etc.] and to design better combinations of techniques and confinement materials. In order to obtain the stress–strain curves due to passive confinement, an analogy between square and circular sections has been introduced. In this way, any active confinement model derived by triaxial tests on cylindrical specimens can be used. The model has been validated by comparing its predict...
1 November 2012 in Journal of Structural Engineering
This paper presents a simplified model for describing the response of a longitudinal bar embedded in concrete, taking into account the bond-slip phenomenon. The model is developed by assuming a linear bond-slip field along the bar anchorage length and provides a simplified stress-strain relationship to assign to the longitudinal reinforcement. The analytical approach adopted makes the proposed model very convenient from a computational standpoint because, unlike many other refined models, it does not require a multilevel iterative process. Moreover, the assumptions made are particularly appropriate for modeling bond-slip of smooth bars generally used in older reinforced concrete buildings. The implementation strategy of the proposed bond-slip model in general-purpose nonlinear structural analysis software and comparisons with experimental results are discussed in a companion paper.
The paper illustrates the results of experimental tests performed on sub-assemblages of R/C (Reinforced Concrete) existing structures, designed only for gravity loads In order to estimate failure mechanisms and ductility properties, four internal and external R/C beam-column joints were built and tested. The specimens were built by using concrete with low strength and smooth reinforcing bars, without hoops into the panel zone. The tests were performed by increasing cyclic horizontal displacements up to the collapse. The experimental results show that seismic response of these kind of structures is mainly influenced by bond slips of longitudinal bars, and that the shear collapse regards external joints rather the internal ones. Failure mechanisms observed (column plastic hingings for internal joints, shear failure for external joints) point out the vulnerability of these structures due to the soft storey mechanism. The study is significant for better understanding of the inelastic seismic behavior of the R/C existing buildings with smooth bars, and for evaluating the effectiveness of the model classical assumptions.