Alberto Gomez

Dr. Alberto Gomez

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 October 2017 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
PYPouya Youssefi
Pouya Youssefi
AGAlberto Gomez
Alberto Gomez
CAChristopher Arthurs
Christopher Arthurs
RSRajan Sharma
Rajan Sharma
MJMarjan Jahangiri
Marjan Jahangiri
C. Alberto FigueroaC. Alberto Figueroa
C. Alberto Figueroa
Computational fluid dynamics (CFD) provides a noninvasive method to functionally assess aortic hemodynamics. The thoracic aorta has an anatomically complex inlet comprising of the aortic valve and root, which is highly prone to different morphologies and pathologies. We investigated the effect of using patient-specific (PS) inflow velocity profiles compared to idealized profiles based on the patient's flow waveform. A healthy 31 yo with a normally functioning tricuspid aortic valve (subject A), and a 52 yo with a bicuspid aortic valve (BAV), aortic valvular stenosis, and dilated ascending aorta (subject B) were studied. Subjects underwent MR angiography to image and reconstruct three-dimensional (3D) geometric models of the thoracic aorta. Flow-magnetic resonance imaging (MRI) was acquired above the aortic valve and used to extract the patient-specific velocity profiles. Subject B's eccentric asymmetrical inflow profile led to highly complex velocity patterns, which were not replicated by the idealized velocity profiles. Despite having identical flow rates, the idealized inflow profiles displayed significantly different peak and radial velocities. Subject A's results showed some similarity between PS and parabolic inflow profiles; however, other parameters such as Flowasymmetry were significantly different. Idealized inflow velocity profiles significantly alter velocity patterns and produce inaccurate hemodynamic assessments in the thoracic aorta. The complex structure of the aortic valve and its predisposition to pathological change means the inflow into the thoracic aorta can be highly variable. CFD analysis of the thoracic aorta needs to utilize fully PS inflow boundary conditions in order to produce truly meaningful results.

10 May 2021 in PLOS Computational Biology
Verified
Journal Article
Open access
PDF file
CAChristopher J. Arthurs
Christopher J. Arthurs
RKRostislav Khlebnikov
Rostislav Khlebnikov
AMAlex Melville
Alex Melville
MMMarija Marčan
Marija Marčan
AGAlberto Gomez
Alberto Gomez
C. Alberto FigueroaC. Alberto Figueroa
C. Alberto Figueroa
In this work, we describe the CRIMSON (CardiovasculaR Integrated Modelling and SimulatiON) software environment. CRIMSON provides a powerful, customizable and user-friendly system for performing three-dimensional and reduced-order computational haemodynamics studies via a pipeline which involves: 1) segmenting vascular structures from medical images; 2) constructing analytic arterial and venous geometric models; 3) performing finite element mesh generation; 4) designing, and 5) applying boundary conditions; 6) running incompressible Navier-Stokes simulations of blood flow with fluid-structure interaction capabilities; and 7) post-processing and visualizing the results, including velocity, pressure and wall shear stress fields. A key aim of CRIMSON is to create a software environment that makes powerful computational haemodynamics tools accessible to a wide audience, including clinicians and students, both within our research laboratories and throughout the community. The overall philosophy is to leverage best-in-class open source standards for medical image processing, parallel flow computation, geometric solid modelling, data assimilation, and mesh generation. It is actively used by researchers in Europe, North and South America, Asia, and Australia. It has been applied to numerous clinical problems; we illustrate applications of CRIMSON to real-world problems using examples ranging from pre-operative surgical planning to medical device design optimization. We provide the first full presentation in the literature of CRIMSON, the Cardiovascular Integrated Modelling and Simulation Package. CRIMSON consists of a graphical user interface desktop computer program for creating geometric models of blood vessels from medical imaging scans, specifying parameters such as the stiffness of the artery walls, the resistance of connected vessels which are not visible on the scans, and determining the appropriate parameters for all aspects of the model. CRIMSON additionally consists of the Flowsolver, a high-performance computing package which simulates the flow of blood through the models created in the graphical user interface. Whilst several packages which can simulate blood flow exist, most target general fluid simulations, and this lack of specialisation means that blood flow simulation is harder to perform, and can require ad hoc (and potentially scientifically-limiting) workflow decisions. CRIMSON’s specialisation deals with these problems, as well as presenting a number of unique features which are unavailable elsewhere.

1 October 2023
Verified
Book Chapter
Open access
PDF file
DSDavid Stojanovski
David Stojanovski
UHUxio Hermida
Uxio Hermida
Pablo LamataPablo Lamata
Pablo Lamata
ABArian Beqiri
Arian Beqiri
AGAlberto Gomez
Alberto Gomez
We propose a novel pipeline for the generation of synthetic ultrasound images via Denoising Diffusion Probabilistic Models (DDPMs) guided by cardiac semantic label maps. We show that these synthetic images can serve as a viable substitute for real data in the training of deep-learning models for ultrasound image analysis tasks such as cardiac segmentation. To demonstrate the effectiveness of this approach, we generated synthetic 2D echocardiograms and trained a neural network for segmenting the left ventricle and left atrium. The performance of the network trained on exclusively synthetic images was evaluated on an unseen dataset of real images and yielded mean Dice scores of $$88.6 \pm 4.91$$ 88.6 ± 4.91 , $$91.9 \pm 4.22$$ 91.9 ± 4.22 , $$85.2 \pm 4.83$$ 85.2 ± 4.83 % for left ventricular endocardium, epicardium and left atrial segmentation respectively. This represents a relative increase of 9.2, 3.3 and 13.9% in Dice scores compared to the previous state-of-the-art. The proposed pipeline has potential for application to a wide range of other tasks across various medical imaging modalities.

25 April 2019 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Open access
QMQingjie Meng
Qingjie Meng
JHJames Housden
James Housden
JMJacqueline Matthew
Jacqueline Matthew
DRDaniel Rueckert
Daniel Rueckert
JSJulia A. Schnabel
Julia A. Schnabel
AGAlberto Gomez
Alberto Gomez
Detecting acoustic shadows in ultrasound images is important in many clinical and engineering applications. Real-time feedback of acoustic shadows can guide sonographers to a standardized diagnostic viewing plane with minimal artifacts and can provide additional information for other automatic image analysis algorithms. However, automatically detecting shadow regions using learning-based algorithms is challenging because pixel-wise ground truth annotation of acoustic shadows is subjective and time consuming. In this paper, we propose a weakly supervised method for automatic confidence estimation of acoustic shadow regions. Our method is able to generate a dense shadow-focused confidence map. In our method, a shadow-seg module is built to learn general shadow features for shadow segmentation, based on global image-level annotations as well as a small number of coarse pixel-wise shadow annotations. A transfer function is introduced to extend the obtained binary shadow segmentation to a reference confidence map. In addition, a confidence estimation network is proposed to learn the mapping between input images and the reference confidence maps. This network is able to predict shadow confidence maps directly from input images during inference. We use evaluation metrics such as DICE, inter-class correlation, and so on, to verify the effectiveness of our method. Our method is more consistent than human annotation and outperforms the state-of-the-art quantitatively in shadow segmentation and qualitatively in confidence estimation of shadow regions. Furthermore, we demonstrate the applicability of our method by integrating shadow confidence maps into tasks such as ultrasound image classification, multi-view image fusion, and automated biometric measurements.

5 June 2019 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
LPLaura Peralta
Laura Peralta
AGAlberto Gomez
Alberto Gomez
YLYing Luan
Ying Luan
BKBae-Hyung Kim
Bae-Hyung Kim
JHJoseph V. Hajnal
Joseph V. Hajnal
RERobert J. Eckersley
Robert J. Eckersley
This work extends the effective aperture size by coherently compounding the received radio frequency data from multiple transducers. As a result, it is possible to obtain an improved image, with enhanced resolution, an extended field of view (FoV), and high-acquisition frame rates. A framework is developed in which an ultrasound imaging system consisting of N synchronized matrix arrays, each with partly shared FoV, take turns to transmit plane waves (PWs). Only one individual transducer transmits at each time while all N transducers simultaneously receive. The subwavelength localization accuracy required to combine information from multiple transducers is achieved without the use of any external tracking device. The method developed in this study is based on the study of the backscattered echoes received by the same transducer and resulting from a targeted scatterer point in the medium insonated by the multiple ultrasound probes of the system. The current transducer locations along with the speed of sound in the medium are deduced by optimizing the cross correlation between these echoes. The method is demonstrated experimentally in 2-D for two linear arrays using point targets and anechoic lesion phantoms. The first demonstration of a free-hand experiment is also shown. Results demonstrate that the coherent multi-transducer ultrasound imaging method has the potential to improve ultrasound image quality, improving resolution, and target detectability. Compared with coherent PW compounding using a single probe, lateral resolution improved from 1.56 to 0.71 mm in the coherent multi-transducer imaging method without acquisition frame rate sacrifice (acquisition frame rate 5350 Hz).

21 September 2018 in Healthcare Technology Letters
Verified
Journal Article
Open access
PDF file
GWGavin Wheeler
Gavin Wheeler
SDShujie Deng
Shujie Deng
NTNicolas Toussaint
Nicolas Toussaint
KPKuberan Pushparajah
Kuberan Pushparajah
JSJulia A. Schnabel
Julia A. Schnabel
AGAlberto Gomez
Alberto Gomez
The authors present a method to interconnect the Visualisation Toolkit (VTK) and Unity. This integration enables them to exploit the visualisation capabilities of VTK with Unity's widespread support of virtual, augmented, and mixed reality displays, and interaction and manipulation devices, for the development of medical image applications for virtual environments. The proposed method utilises OpenGL context sharing between Unity and VTK to render VTK objects into the Unity scene via a Unity native plugin. The proposed method is demonstrated in a simple Unity application that performs VTK volume rendering to display thoracic computed tomography and cardiac magnetic resonance images. Quantitative measurements of the achieved frame rates show that this approach provides over 90 fps using standard hardware, which is suitable for current augmented reality/virtual reality display devices.