Zaoyang Guo

Dr. Zaoyang Guo


Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2013 in Composites Part B: Engineering
Verified
Journal Article
Closed access
Xiongqi PengXiongqi Peng
Xiongqi Peng
ZGZaoyang Guo
Zaoyang Guo
TDTongliang Du
Tongliang Du
WYWoong-Ryeol Yu
Woong-Ryeol Yu

1 August 2007 in Composites Part A: Applied Science and Manufacturing
Verified
Journal Article
Closed access
ZGZaoyang Guo
Zaoyang Guo
Xiongqi PengXiongqi Peng
Xiongqi Peng
BMBrian Moran
Brian Moran

1 June 2008 in Journal of the Mechanics and Physics of Solids
Verified
Journal Article
Closed access
ZGZaoyang Guo
Zaoyang Guo
FCFerhun Cem Caner
Ferhun Cem Caner
Xiongqi PengXiongqi Peng
Xiongqi Peng
BMBrian Moran
Brian Moran

26 February 2007 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
FCFerhun Cem Caner
Ferhun Cem Caner
ZGZaoyang Guo
Zaoyang Guo
BMBrian Moran
Brian Moran
ZBZdeněk P. Bažant
Zdeněk P. Bažant
ICIgnacio Carol
Ignacio Carol
In a recent paper, Peng et al. (2006, “An Anisotropic Hyperelastic Constitutive Model With Fiber-Matrix Interaction for the Human Annulus Fibrosis,” ASME J. Appl. Mech., 73(5), pp. 815–824) developed an anisotropic hyperelastic constitutive model for the human annulus fibrosus in which fiber-matrix interaction plays a crucial role in simulating experimental observations reported in the literature. Later, Guo et al. (2006, “A Composites-Based Hyperelastic Constitutive Model for Soft Tissue With Application to the Human Fibrosis,” J. Mech. Phys. Solids, 54(9), pp. 1952–1971) used fiber reinforced continuum mechanics theory to formulate a model in which the fiber-matrix interaction was simulated using only composite effect. It was shown in these studies that the classical anisotropic hyperelastic constitutive models for soft tissue, which do not account for this shear interaction, cannot accurately simulate the test data on human annulus fibrosus. In this study, we show that the microplane model for soft tissue developed by Caner and Carol (2006, “Microplane Constitutive Model and Computational Framework for Blood Vessel Tissue,” ASME J. Biomech. Eng., 128(3), pp. 419–427) can be adjusted for human annulus fibrosus and the resulting model can accurately simulate the experimental observations without explicit fiber-matrix interaction because, in microplane model, the shear interaction between the individual fibers distributed in the tissue provides the required additional rigidity to explain these experimental facts. The intensity of the shear interaction between the fibers can be adjusted by adjusting the spread in the distribution while keeping the total amount of the fiber constant. A comparison of results obtained from (i) a fiber-matrix parallel coupling model, which does not account for the fiber-matrix interaction, (ii) the same model but enriched with fiber-matrix interaction, and (iii) microplane model for soft tissue adapted to annulus fibrosus with two families of fiber distributions is presented. The conclusions are (i) that varying degrees of fiber-fiber and fiber-matrix shear interaction must be taking place in the human annulus fibrosus, (ii) that this shear interaction is essential to be able to explain the mechanical behavior of human annulus fibrosus, and (iii) that microplane model can be fortified with fiber-matrix interaction in a straightforward manner provided that there are new experimental data on distribution of fibers, which indicate a spread so small that it requires an explicit fiber-matrix interaction to be able to simulate the experimental data.

26 January 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
HWHaipeng Wang
Haipeng Wang
YCYang Chen
Yang Chen
ZGZaoyang Guo
Zaoyang Guo
Yingchun GuanYingchun Guan
Yingchun Guan
Hybrid lightweight components with strong and reliable bonding qualities are necessary for practical applications including in the automotive and aerospace industries. The direct laser joining method has been used to produce hybrid joints of Ti6Al4V and glass fiber reinforced polyamide (PA66-GF30). Prior to the laser joining process, a surface texturing treatment is carried out on Ti6Al4V to improve joint strength through the formation of interlock structures between Ti6Al4V and PA66-GF30. In order to reduce the generated micro-pores in Ti6Al4V-PA66-GF30 joints, a modified laser joining method has been proposed. Results show that only very few small micro-pores are generated in the joints produced by the modified laser joining method, and the fracture strength of the joints is significantly increased from 13.8 MPa to 41.5 MPa due to the elimination of micro-pores in the joints.

1 December 2010 in Computers & Structures
Verified
Journal Article
Closed access
ZGZaoyang Guo
Zaoyang Guo
SYShihui You
Shihui You
XWXiaoping Wan
Xiaoping Wan
NBNenad Bićanić
Nenad Bićanić