Jianyong Zheng

Prof. Jianyong Zheng


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 January 2019 in Journal of Electrical Engineering & Technology
Verified
Journal Article
Closed access
PDF file
YPYi Pan
Yi Pan
FMFei Mei
Fei Mei
HMHuiyu Miao
Huiyu Miao
JZJianyong Zheng
Jianyong Zheng
KZKedong Zhu
Kedong Zhu
HSHaoyuan Sha
Haoyuan Sha

3 July 2019 in IEEE Access
Verified
Journal Article
Open access
YPYi Pan
Yi Pan
FMFei Mei
Fei Mei
CZCheng Zhou
Cheng Zhou
TSTian Shi
Tian Shi
JZJianyong Zheng
Jianyong Zheng
As the coupling and integration of multi-energy flow in the integrated energy system (IES) deepens increasingly, the cascading failure will develop across different energy systems more easily and widely through the energy hub (EH). And it brings great challenges to the security and reliability of IES. The defects of present cascading failure model of IES have been summarized and a novel search strategy of fault chains in IES combined heating and power network was proposed in this paper. Firstly, the initial risk assessment index of each energy branch is proposed to form the initial fault sets. Then combined heat and power control strategies (CHPC) is introduced to deal with the branch overload conditions during the cascading failure. What’s more, in order to reduce the workload and overcome the limitation of present methods, we analyzed the relevance of the branches to be predicted by using Kernel Fuzzy C-means (KFCM) clustering algorithm and selected the branches with the highest value of relevance as the subsequent failure. Based on the predicted fault chain, vulnerability analysis is presented to locate critical component and find out the correlation between cascading outages. Comprehensive evaluation index is also established to effectively evaluate the impact severity of the cascading failure. Finally, the case studies are carried out on the combined heating and power systems to demonstrate the effectiveness of the proposed method.

9 July 2021 in Energies
Verified
Journal Article
Open access
PDF file
WHWeiguo He
Weiguo He
DYDeyang Yin
Deyang Yin
Kaifeng ZhangKaifeng Zhang
Kaifeng Zhang
XZXiangwen Zhang
Xiangwen Zhang
JZJianyong Zheng
Jianyong Zheng
With the widespread attention and research of distributed photovoltaic (PV) systems, the fault detection and diagnosis problems of distributed PV systems has become increasingly prominent. To this end, a distributed PV array fault diagnosis method based on fine-tuning Naive Bayes model for the fault conditions of PV array such as open-circuit, short-circuit, shading, abnormal degradation, and abnormal bypass diode is proposed. First, in view of the problem of less distributed PV fault data, a fine-tuning Naive Bayes model (FTNB) is proposed to improve the diagnosis accuracy. Second, the failure sample set is used to train the model. Then, the maximum power point data of the PV inverter and the meteorological data are collected for fault diagnosis. Finally, the effectiveness and accuracy of the proposed method are verified by the analysis of simulation. In addition, this method requires only a small number of fault sample sets and no additional measurement equipment is required, which is suitable for real-time monitoring of distributed PV systems.

10 October 2019 in Energies
Verified
Journal Article
Open access
PDF file
CZCheng Zhou
Cheng Zhou
JZJianyong Zheng
Jianyong Zheng
SLSai Liu
Sai Liu
YLYu Liu
Yu Liu
FMFei Mei
Fei Mei
JWJianzhang Wu
Jianzhang Wu
Multi-district integrated energy system (IES) can make full use of the complementary characteristics of district power and thermal system, and loads in different districts. It can improve the flexibility and economy of system operation, which has a good development prospect. Firstly, based on the general energy transfer model of the district heating network (DHN), the DHN system is described by the basic equations of the heating network and nodes considering the characteristics of the transmission time delay and heat loss in pipelines. A coupling model of DHN and multi-district IES is established. Secondly, the flexible demand response (FDR) model of electric and thermal loads is established. The load characteristics of each district in IES are studied. A shiftable load model based on the electric quantity balance is constructed. Considering the flexibility of the heat demand, a thermal load adjustment model based on the comfort constraint is constructed to make the thermal load elastic and controllable in time and space. Finally, a mixed integer linear programming (MILP) model for operation optimization of multi-district IES with the DHN considering the FDR of electric and thermal loads is established based on the supply and demand sides. The result shows that the proposed model makes full use of the complementary characteristics of electric and thermal loads in different districts. It realizes the coordinated distribution of thermal energy among different districts and improves the efficiency of thermal energy utilization through the DHN. FDR effectively reduces the peak-valley difference of loads. It further reduces the total operating cost by the coordinated operation of the DHN and multi-district IES.

26 March 2019 in Energies
Verified
Journal Article
Open access
PDF file
HMHuiyu Miao
Huiyu Miao
FMFei Mei
Fei Mei
YYYun Yang
Yun Yang
HCHongfei Chen
Hongfei Chen
JZJianyong Zheng
Jianyong Zheng
A virtual synchronous machine (VSM) is a converter which, compared to other types of converters, has more friendly interactions with the power grid because it is able to simulate the external characteristics of a synchronous machine, which can provide virtual inertia and damping. When the grid voltage is unbalanced, there will be negative sequence current and power oscillations. There will also be double-frequency ripples on the DC bus, which affect the normal operation of the DC power source or load. In order to solve these problems, a comprehensive control strategy is proposed in this paper. The principle of a VSM operated as a current source converter, also called VISMA, is used in the design. A complex coefficient filter is applied to separate the positive and negative sequence components of the grid voltage. By analyzing the reasons of power oscillations under unbalanced voltage, the electrical simulation part of the VSM is improved to achieve several objectives: to suppress negative sequence current and DC voltage ripples. Additionally, the rated voltage in the reactive control part is adaptively adjusted to stabilize the system. The validity of the proposed control strategy is verified by simulation and experiment.

1 December 2020
Verified
Conference Paper
Closed access
XHXiao Han
Xiao Han
SSShan Song
Shan Song
YWYang Wang
Yang Wang
MWMengfan Wang
Mengfan Wang
XLXuan Li
Xuan Li
JZJianyong Zheng
Jianyong Zheng
With the development of wind-solar-battery power system and the increasingly strict requirements of consumers for power quality, it is of great significance to evaluate the power quality of wind-solar-battery power system both accurately and comprehensively. This paper constructs the evaluation index system of power quality applicable to the wind-solar-battery power system. On this basis, it establishes a comprehensive evaluation model based on the fuzzy analytic hierarchy process (FAHP) and improved grey relational analysis (GRA). The model takes the existing experience into account during the decision-making process, integrating the index value coefficient into the objective correlation degree. While introducing the adjustment strategy of dynamic resolution coefficient, this model makes up for the shortcomings of the traditional grey relational analysis, and realizes the good combination of subjective expert experience and objective node data. Finally, a case study was provided to verify the feasibility and effectiveness of the proposed method.