Ion-selective field effect transistors (ISFETs) exhibit instability, commonly known as drift, in the form of a slow, monotonic, temporal increase in the threshold voltage of the device. A method for counteracting instability inspired by a physical model for threshold voltage drift in pH-sensitive ISFETs is presented. This method involves adjusting the charge density at the insulator-semiconductor interface using threshold-setting ion implantation such that the net charge induced in the semiconductor at the operating point of the device is minimized. The proposed method is analytically validated based on characterization and modeling of drift in an Al 2 O 3 -gate pH-sensitive ISFET. Counteraction of ISFET drift by ion implantation is also demonstrated using TCAD simulations. The optimum donor-type implant dose of 3.25×10 11 cm -2 determined based on ATLAS simulations is in good agreement with the corresponding dose of 6.58 × 10 11 cm -2 obtained analytically.
Accurate and cost-effective integrated sensor systems for continuous monitoring of pH and blood gases continue to be in high demand. The capacity of ion-selective and Gas-sensitive field effect transistors (FETs) to serve as low-power sensors for accurate continuous monitoring of pH and blood gases is evaluated in the amperometric or current mode of operation. A stand-alone current-mode topology is employed in which a constant bias is applied to the gate with the drain current serving as the measuring signal. Compared with voltage-mode operation (e.g., in the feedback mode in ion-selective FETs), current-mode topologies offer the advantages of small size and low power consumption. However, the ion-selective FET (ISFET) and the Gas-sensitive FET (GasFET) exhibit a similar drift behavior, imposing a serious limitation on the accuracy of these sensors for continuous monitoring applications irrespective of the mode of operation. Given the slow temporal variation associated with the drift characteristics in both devices, a common post-processing technique that involves monitoring the variation of the drain current over short intervals of time can potentially allow extraction of the measuring signal in presence of drift in both sensor types. Furthermore, in the amperometric mode the static sensitivity of a FET-based sensor, given by the product of the FET transconductance and the sensitivity of the device threshold voltage to the measurand concentration, can be increased by adjusting the device design parameters. Increasing the sensitivity, while of interest in its own right, also enhances the accuracy of the proposed method. Rigorous analytical validation of the method is presented for GasFET operation in the amperometric mode. Moreover, the correction algorithm is verified experimentally using a Si3N4-gate ISFET operating in the amperometric mode to monitor pH variations ranging from 3.5 to 10.
29 April 2020 in Current Pharmaceutical Biotechnology
Background: Treatment of neurological diseases using systemic and non-surgical techniques presents a significant challenge in medicine. This challenge is chiefly associated with the condensation and coherence of the brain tissue. Methods: The coherence structure of the brain is due to the presence of the blood-brain barrier (BBB), which consists of a continuous layer of capillary endothelial cells. The BBB prevents most drugs from entering the brain tissue and is highly selective, permitting only metabolic substances and nutrients to pass through. Results: Although this challenge has caused difficulties for the treatment of neurological diseases, it has opened up a broad research area in the field of drug delivery. Through the utilization of nanoparticles (NPs), nanotechnology can provide the ideal condition for passing through the BBB. Conclusion: NPs with suitable dimensions and optimum hydrophobicity and charge, as well as appropriate functionalization, can accumulate in the brain. Furthermore, NPs can facilitate the targeted delivery of therapeutics into the brain areas involved in Alzheimer’s disease, Parkinson’s disease, stroke, glioma, migraine, and other neurological disorders. This review describes these methods of actively targeting specific areas of the brain.
The accuracy of the ion-selctive field effect transistor (ISFET) is limited by errors ascribed to drift and hysteresis. In this work operation of the ISFET as a stand-alone pH sensor operating in the current mode is demonstrated, the dependence of drift on pH is characterized and modeled, and the relationship between drift and hysteresis is investigated. Also, a post-processing method for extraction of the ISFET current signal in the presence of drift and hysteresis is formally developed. This method, which is based on sampling the drain current over relatively short time intervals, is verified experimentally in the presence of drift and hysteresis by monitoring step changes in pH using a Si3N4-gate ISFET biased in the triode region with the pH of the solution cycled up and down over a seven-unit range. The corrective algorithm was also demonstrated by extracting the measuring signal using an Al2O3-gate ISFET operating in the current mode to monitor pH variations ranging from 4 to 10. The theoretical basis of the proposed method is validated by developing the concept of signal-to-drift ratio as a figure of merit for the resolution of pH-sensitive ISFETs. The signal-to-drift ratio is shown to increase in proportion to the ISFET transconductance (gm) suggesting that the optimization of gm can improve the resolution of pH readings. SPICE simulations based on the measured drift data for the Si3N4-gate ISFET indicated an approximately 0.1pH unit improvement in the accuracy of the ISFET for a two-fold increase in the aspect ratio of the channel (W/L).