Andreas Mai

Prof. Andreas Mai

orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 January 2019 in Molecules
Verified
Journal Article
Open access
PDF file
Patrick SteglichPatrick Steglich
Patrick Steglich
MHMarcel Hülsemann
Marcel Hülsemann
BDBirgit Dietzel
Birgit Dietzel
AMAndreas Mai
Andreas Mai
Recent developments in optical biosensors based on integrated photonic devices are reviewed with a special emphasis on silicon-on-insulator ring resonators. The review is mainly devoted to the following aspects: (1) Principles of sensing mechanism, (2) sensor design, (3) biofunctionalization procedures for specific molecule detection and (4) system integration and measurement set-ups. The inherent challenges of implementing photonics-based biosensors to meet specific requirements of applications in medicine, food analysis, and environmental monitoring are discussed.

8 October 2015 in Optics Express
Verified
Journal Article
Open access
PDF file
SLStefan Lischke
Stefan Lischke
DKDieter Knoll
Dieter Knoll
CMChristian Mai
Christian Mai
LZLars Zimmermann
Lars Zimmermann
APAnna Peczek
Anna Peczek
AMAndreas Mai
Andreas Mai
A novel waveguide-coupled germanium p-i-n photodiode is demonstrated which combines high responsivity with very high −3 dB bandwidth at a medium dark current. Bandwidth values are 40 GHz at zero bias and more than 70 GHz at −1 V. Responsivity at 1.55 µm wavelength ranges from 0.84 A/W at zero bias to 1 A/W at −1 V. Room temperature dark current density at −1 V is about 1 A/cm2. The high responsivity mainly results from the use of a new, low-loss contact scheme, which moreover also reduces the negative effect of photo carrier diffusion on bandwidth.

23 August 2010 in IEEE Journal of Solid-State Circuits
Verified
Journal Article
Closed access
HRHolger Rucker
Holger Rucker
BHBernd Heinemann
Bernd Heinemann
WWWolfgang Winkler
Wolfgang Winkler
RBR. Barth
R. Barth
JBJ. Borngraber
J. Borngraber
YYYuji Yamamoto
Yuji Yamamoto
A 0.13 μm SiGe BiCMOS technology for millimeter-wave applications is presented. This technology features high-speed HBTs with peak transit frequencies f T of 240 GHz, maximum oscillation frequencies f max of 330 GHz, and breakdown voltages BV CEO of 1.7 V along with high-voltage HBTs ( f T = 50 GHz, f max = 130 GHz, BV CEO = 3.7 V) integrated in a dual gate oxide RF-CMOS process. Ring oscillator gate delays of 2.9 ps, low-noise amplifiers for 122 GHz, and LC oscillators with fundamental-mode oscillation frequencies above 200 GHz are demonstrated.

13 October 2021 in IEEE Sensors Journal
Verified
Journal Article
Closed access
Patrick SteglichPatrick Steglich
Patrick Steglich
DRDominik G. Rabus
Dominik G. Rabus
CSCinzia Sada
Cinzia Sada
MPMartin Paul
Martin Paul
MWMichael G. Weller
Michael G. Weller
AMAndreas Mai
Andreas Mai
Silicon photonic micro-ring resonators (MRR) developed on the silicon-on-insulator (SOI) platform, owing to their high sensitivity and small footprint, show great potential for many chemical and biological sensing applications such as label-free detection in environmental monitoring, biomedical engineering, and food analysis. In this tutorial, we provide the theoretical background and give design guidelines for SOI-based MRR as well as examples of surface functionalization procedures for label-free detection of molecules. After introducing the advantages and perspectives of MRR, fundamentals of MRR are described in detail, followed by an introduction to the fabrication methods, which are based on a complementary metal-oxide semiconductor (CMOS) technology. Optimization of MRR for chemical and biological sensing is provided, with special emphasis on the optimization of waveguide geometry. At this point, the difference between chemical bulk sensing and label-free surface sensing is explained, and definitions like waveguide sensitivity, ring sensitivity, overall sensitivity as well as the limit of detection (LoD) of MRR are introduced. Further, we show and explain chemical bulk sensing of sodium chloride (NaCl) in water and provide a recipe for label-free surface sensing.

30 November 2016 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
MLMindaugas Lukosius
Mindaugas Lukosius
JDJaroslaw Dabrowski
Jaroslaw Dabrowski
JKJulia Kitzmann
Julia Kitzmann
OFOksana Fursenko
Oksana Fursenko
FAFatima Akhtar
Fatima Akhtar
GLGrzegorz Lupina
Grzegorz Lupina

9 April 2022 in Sensors
Verified
Journal Article
Open access
PDF file
Patrick SteglichPatrick Steglich
Patrick Steglich
GLGiulia Lecci
Giulia Lecci
AMAndreas Mai
Andreas Mai
Label-free direct-optical biosensors such as surface-plasmon resonance (SPR) spectroscopy has become a gold standard in biochemical analytics in centralized laboratories. Biosensors based on photonic integrated circuits (PIC) are based on the same physical sensing mechanism: evanescent field sensing. PIC-based biosensors can play an important role in healthcare, especially for point-of-care diagnostics, if challenges for a transfer from research laboratory to industrial applications can be overcome. Research is at this threshold, which presents a great opportunity for innovative on-site analyses in the health and environmental sectors. A deeper understanding of the innovative PIC technology is possible by comparing it with the well-established SPR spectroscopy. In this work, we shortly introduce both technologies and reveal similarities and differences. Further, we review some latest advances and compare both technologies in terms of surface functionalization and sensor performance.