Beate Strehlitz

Dr. Beate Strehlitz

Department Environmental and Biotechnology Centre, Helmholtz Centre for Environmental Research – UFZ, Permoserstr. 15, 04318 Leipzig, Germany
orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 July 2005 in Analytical and Bioanalytical Chemistry
Verified
Journal Article
Closed access
PDF file
Regina StoltenburgRegina Stoltenburg
Regina Stoltenburg
CRC. Reinemann
C. Reinemann
Beate StrehlitzBeate Strehlitz
Beate Strehlitz

30 December 2012 in Journal of Analytical Methods in Chemistry
Verified
Journal Article
Open access
PDF file
Regina StoltenburgRegina Stoltenburg
Regina Stoltenburg
NNNadia Nikolaus
Nadia Nikolaus
Beate StrehlitzBeate Strehlitz
Beate Strehlitz
Small organic molecules are challenging targets for an aptamer selection using the SELEX technology (SELEX—Systematic Evolution of Ligans by EXponential enrichment). Often they are not suitable for immobilization on solid surfaces, which is a common procedure in known aptamer selection methods. The Capture-SELEX procedure allows the selection of DNA aptamers for solute targets. A special SELEX library was constructed with the aim to immobilize this library on magnetic beads or other surfaces. For this purpose a docking sequence was incorporated into the random region of the library enabling hybridization to a complementary oligo fixed on magnetic beads. Oligonucleotides of the library which exhibit high affinity to the target and a secondary structure fitting to the target are released from the beads for binding to the target during the aptamer selection process. The oligonucleotides of these binding complexes were amplified, purified, and immobilized via the docking sequence to the magnetic beads as the starting point of the following selection round. Based on this Capture-SELEX procedure, the successful DNA aptamer selection for the aminoglycoside antibiotic kanamycin A as a small molecule target is described.

23 July 2008 in Sensors
Verified
Journal Article
Open access
PDF file
Beate StrehlitzBeate Strehlitz
Beate Strehlitz
NNNadia Nikolaus
Nadia Nikolaus
Regina StoltenburgRegina Stoltenburg
Regina Stoltenburg
Aptamers have been developed for different applications. Their use as new biological recognition elements in biosensors promises progress for fast and easy detection of proteins. This new generation of biosensor (aptasensors) will be more stable and well adapted to the conditions of real samples because of the specific properties of aptamers.

7 September 2007 in Microchimica Acta
Verified
Journal Article
Closed access
PDF file
NNNadia Nikolaus
Nadia Nikolaus
Beate StrehlitzBeate Strehlitz
Beate Strehlitz

Verified
Journal Article
Open access
PDF file
PRPeggy Reich
Peggy Reich
Regina StoltenburgRegina Stoltenburg
Regina Stoltenburg
Beate StrehlitzBeate Strehlitz
Beate Strehlitz
DFDieter Frense
Dieter Frense
DBDieter Beckmann
Dieter Beckmann
In combination with electrochemical impedance spectroscopy, aptamer-based biosensors are a powerful tool for fast analytical devices. Herein, we present an impedimetric aptasensor for the detection of the human pathogen Staphylococcus aureus. The used aptamer targets protein A, a surface bound virulence factor of S. aureus. The thiol-modified protein A-binding aptamer was co-immobilized with 6-mercapto-1-hexanol onto gold electrodes by self-assembly. Optimization of the ratio of aptamer to 6-mercapto-1-hexanol resulted in an average density of 1.01 ± 0.44 × 1013 aptamer molecules per cm2. As shown with quartz crystal microbalance experiments, the immobilized aptamer retained its functionality to bind recombinant protein A. Our impedimetric biosensor is based on the principle that binding of target molecules to the immobilized aptamer decreases the electron transfer between electrode and ferri-/ferrocyanide in solution, which is measured as an increase of impedance. Microscale thermophoresis measurements showed that addition of the redox probe ferri-/ferrocyanide has no influence on the binding of aptamer and its target. We demonstrated that upon incubation with various concentrations of S. aureus, the charge-transfer resistance increased proportionally. The developed biosensor showed a limit of detection of 10 CFU·mL−1 and results were available within 10 minutes. The biosensor is highly selective, distinguishing non-target bacteria such as Escherichia coli and Staphylococcus epidermidis. This work highlights the immense potential of impedimetric aptasensors for future biosensing applications.

17 December 2011 in Bioanalytical Reviews
Verified
Journal Article
Open access
PDF file
Beate StrehlitzBeate Strehlitz
Beate Strehlitz
CRChristine Reinemann
Christine Reinemann
SLSoeren Linkorn
Soeren Linkorn
Regina StoltenburgRegina Stoltenburg
Regina Stoltenburg
Aptamers are single-stranded DNA or RNA oligonucleotides, which are able to bind with high affinity and specificity to their target. This property is used for a multitude of applications, for instance as molecular recognition elements in biosensors and other assays. Biosensor application of aptamers offers the possibility for fast and easy detection of environmental relevant substances. Pharmaceutical residues, deriving from human or animal medical treatment, are found in surface, ground, and drinking water. At least the whole range of frequently administered drugs can be detected in noticeable concentrations. Biosensors and assays based on aptamers as specific recognition elements are very convenient for this application because aptamer development is possible for toxic targets. Commonly used biological receptors for biosensors like enzymes or antibodies are mostly unavailable for the detection of pharmaceuticals. This review describes the research activities of aptamer and sensor developments for pharmaceutical detection, with focus on environmental applications.