In the present work, a novel electrochemical sensor was developed for the detection of trace cadmium with high sensitivity and selectivity in an easy and eco-friendly way. Firstly, a glassy carbon electrode (GCE) was modified with nontoxic sodium carboxymethyl cellulose (CMC) by a simple drop-casting method, which was applied to detect cadmium by differential pulse anodic stripping voltammetry (DPASV) in a solution containing both target cadmium and eco-friendly bismuth ions, based on a quick electro-codeposition of these two metal ions on the surface of the modified electrode (CMC-GCE). Investigated by scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS), and Fourier transform infrared spectroscopy (FT-IR), both CMC (with good film-forming ability) and bismuth (with well-defined stripping signal) were found to be well complexed with target cadmium, leading to vital signal amplification for cadmium detection at a sub-nanomolar level. Under the optimal conditions, the proposed sensor exhibited a good linear stripping signal response to cadmium (Ⅱ) ion, in a concentration range of 0.001 μmol/L–1 μmol/L with a limit of detection of 0.75 nmol/L (S/N = 3). Meanwhile, the results demonstrate that this novel electrochemical sensor has excellent sensitivity and reproducibility, which can be used as a promising detection technique for testing natural samples such as tap water.
Cryoprotective effect of silver carp muscle hydrolysate (SCMH) on baker's yeast (Saccharomyces cerevisiae) was examined by analyzing the growth and survival of the yeast during freeze–thaw cycles, and the physicochemical properties [ultrastructure, intracellular proteins and fatty acids, external ice formation (EIF) and internal ice formation (IIF), freezable water content] of yeast cells with or without SCMH through transmission electron microscopy, SDS‐PAGE, GC‐MS, and differential scanning calorimetry. The 4% of SCMH treatment exhibited good yeast cryoprotective activity and increased the yeast survival rate from 0.71% to 90.95% after 1 freeze–thaw cycle as compared to the control. The results demonstrated that the addition of SCMH could attenuate the freeze damage of yeast cells, prevent the degradation or loss of soluble proteins, and increase the composition and absolute content of fatty acids. Besides, the addition of 4% SCMH caused a drop in the EIF peak temperature (from −17.95℃ to −25.14℃) and a decrease in the IIF and freezable water content of yeast cells.
Highly efficient electrochemical detection of Pb 2+ is achieved by the composite CuS/g-C 3 N 4 , based on a synergistic effect of “coordination/adsorption” on Pb 2+ provided by both g-C 3 N 4 and CuS. The limit of detection is as low as 4 nM.