Arangarajan Vinayagam

Dr. Arangarajan Vinayagam

Department of Electrical and Electronics Engineering, New Horizon College of Engineering, Bangalore, India;
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 February 2021 in IEEE Access
Verified
Journal Article
Open access
VVVeerapandiyan Veerasamy
Veerapandiyan Veerasamy
NOOR IZZRI ABDUL WAHABNOOR IZZRI ABDUL WAHAB
NOOR IZZRI ABDUL WAHAB
MOMohammad Lutfi Othman
Mohammad Lutfi Othman
Sanjeevikumar PadmanabanSanjeevikumar Padmanaban
Sanjeevikumar Padmanaban
KSKavaskar Sekar
Kavaskar Sekar
MIMohammad Zohrul Islam
Mohammad Zohrul Islam
This paper presents the detection of High Impedance Fault (HIF) in solar Photovoltaic (PV) integrated power system using recurrent neural network-based Long Short-Term Memory (LSTM) approach. For study this, an IEEE 13-bus system was modeled in MATLAB/Simulink environment to integrate 300 kW solar PV systems for analysis. Initially, the three-phase current signal during non-faulty (regular operation, capacitor switching, load switching, transformer inrush current) and faulty (HIF, symmetrical and unsymmetrical fault) conditions were used for extraction of features. The signal processing technique of Discrete Wavelet Transform with db4 mother wavelet was applied to extract each phase's energy value features for training and testing the classifiers. The proposed LSTM classifier gives the overall classification accuracy of 91.21% with a success rate of 92.42 % in identifying HIF in PV integrated power network. The prediction results obtained from the proffered method are compared with other well-known classifiers of K-Nearest neighbor's network, Support vector machine, J48 based decision tree, and Naïve Bayes approach. Further, the classifier's robustness is validated by evaluating the performance indices (PI) of kappa statistic, precision, recall, and F-measure. The results obtained reveal that the proposed LSTM network significantly outperforms all PI compared to other techniques.

1 April 2021 in Measurement
Verified
Journal Article
Closed access
PRPadmavathi Radhakrishnan
Padmavathi Radhakrishnan
KRKalaivani Ramaiyan
Kalaivani Ramaiyan
Arangarajan VinayagamArangarajan Vinayagam
Arangarajan Vinayagam
VVVeerapandiyan Veerasamy
Veerapandiyan Veerasamy

20 July 2021 in IEEE Access
Verified
Journal Article
Open access
RFRizwan A. Farade
Rizwan A. Farade
NOOR IZZRI ABDUL WAHABNOOR IZZRI ABDUL WAHAB
NOOR IZZRI ABDUL WAHAB
Diaa-Eldin A. MansourDiaa-Eldin A. Mansour
Diaa-Eldin A. Mansour
NANorhafiz Azis
Norhafiz Azis
JJJasronita Jasni
Jasronita Jasni
TKT. M. Yunus Khan
T. M. Yunus Khan
Nanoparticles are generally anti-lipophilic and have a tendency to aggregate when they are embedded in nanofluids. Thus, surfactants have a major role in achieving long term dispersion stability of nanofluids through surface modification of nanoparticles. However, the surfactant changes the structure of the interfacial zone around nanoparticles and can have a crucial impact on the dielectric properties of dielectric nanofluids. Accordingly, this paper aims to clarify the role of interfacial zone on dielectric properties of vegetable oil based Al 2 O 3 nanofluids including relative permittivity, dissipation factor, and AC breakdown voltage. Moreover, a polarization model of nanofluids was proposed to calculate their relative permittivity considering surfactant effect. Different filler levels ranging from 0.01 wt% to 0.05 wt% were used and various temperature ranges were considered to validate the proposed model. Relative permittivity calculated from the proposed model was almost in line with experimental results. Proposed model depicted that surfactant contributes for orientational polarization of nanoparticles in the relative permittivity calculation. So, improvement in the relative permittivity of dielectric nanofluids has been attained from 0.01 wt% to 0.05 wt% of Al 2 O 3 nanoparticles due to both internal and orientational polarization of nanoparticles. Regarding dissipation factor of prepared nanofluids, it decreased against the weight percentage of nanoparticles, while the mean AC breakdown voltage increased against the weight percentage. All these effects were discussed considering the structure of interfacial zone and its impact on the alignment of oil chains and the energy loss of electrons.

1 December 2019 in Sustainable Energy, Grids and Networks
Verified
Journal Article
Closed access
Arangarajan VinayagamArangarajan Vinayagam
Arangarajan Vinayagam
Asma AzizAsma Aziz
Asma Aziz
BPBalasubramaniyam Pm
Balasubramaniyam Pm
JCJaideep Chandran
Jaideep Chandran
VVVeerapandiyan Veerasamy
Veerapandiyan Veerasamy
AGAmeen Gargoom
Ameen Gargoom

4 December 2019 in Sustainability
Verified
Journal Article
Open access
PDF file
VVVeerapandiyan Veerasamy
Veerapandiyan Veerasamy
NOOR IZZRI ABDUL WAHABNOOR IZZRI ABDUL WAHAB
NOOR IZZRI ABDUL WAHAB
RRRajeswari Ramachandran
Rajeswari Ramachandran
Arangarajan VinayagamArangarajan Vinayagam
Arangarajan Vinayagam
MOMohammad Lutfi Othman
Mohammad Lutfi Othman
JKJeevitha Kandasamy
Jeevitha Kandasamy
This paper proposes a new population-based hybrid particle swarm optimized-gravitational search algorithm (PSO-GSA) for tuning the parameters of the proportional-integral-derivative (PID) controller of a two-area interconnected dynamic power system with the presence of nonlinearities such as generator rate constraints (GRC) and governor dead-band (GDB). The tuning of controller parameters such as Kp, Ki, and Kd are obtained by minimizing the objective function formulated using the steady-state performance indices like Integral absolute error (IAE) of tie-line power and frequency deviation of interconnected system. To test the robustness of the propounded controller, the system is studied with system uncertainties, such as change in load demand, synchronizing power coefficient and inertia constant. The two-area interconnected power system (TAIPS) is modeled and simulated using Matlab/Simulink. The results exhibit that the steady-state and transient performance indices such as IAE, settling time, and control effort are impressively enhanced by an amount of 87.65%, 15.39%, and 91.17% in area-1 and 86.46%, 41.35%, and 91.04% in area-2, respectively, by the proposed method compared to other techniques presented. The minimum control effort of PSO-GSA-tuned PID controller depicts the robust performance of the controller compared to other non-meta-heuristic and meta-heuristic methods presented. The proffered method is also validated using the hardware-in-the-loop (HIL) real-time digital simulation to study the effectiveness of the controller.

7 May 2022 in Sustainability
Verified
Journal Article
Open access
PDF file
NSNANDAKUMAR SUNDARARAJU
NANDAKUMAR SUNDARARAJU
Arangarajan VinayagamArangarajan Vinayagam
Arangarajan Vinayagam
VVVeerapandiyan Veerasamy
Veerapandiyan Veerasamy
Gunasekaran SubramaniamGunasekaran Subramaniam
Gunasekaran Subramaniam
In this work, a chaotic search-based hybrid Sperm Swarm Optimized-Gravitational Search Algorithm (CSSO-GSA) is proposed for automatic load frequency control (ALFC) of a hybrid power system (HPS). The HPS model is developed using multiple power sources (thermal, bio-fuel, and renewable energy (RE)) that generate power to balance the system’s demand. To regulate the frequency of the system, the control parameters of the proportional-integral-derivative (PID) controller for ALFC are obtained by minimizing the integral time absolute error of HPS. The effectiveness of the proposed technique is verified with various combinations of power sources (all sources, thermal with bio-fuel, and thermal with RE) connected into the system. Further, the robustness of the proposed technique is investigated by performing a sensitivity analysis considering load variation and weather intermittency of RE sources in real-time. However, the type of RE source does not have any severe impact on the controller but the uncertainties present in RE power generation required a robust controller. In addition, the effectiveness of the proposed technique is validated with comparative and stability analysis. The results show that the proposed CSSO-GSA strategy outperforms the SSO, GSA, and hybrid SSO-GSA methods in terms of steady-state and transient performance indices. According to the results of frequency control optimization, the main performance indices such as settling time (ST) and integral time absolute error (ITAE) are significantly improved by 60.204% and 40.055% in area 1 and 57.856% and 39.820% in area 2, respectively, with the proposed CSSO-GSA control strategy compared to other existing control methods.