Gerald Matson

Dr. Gerald Matson


Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 December 2013 in Materials
Verified
Journal Article
Open access
PDF file
HLHui Liu
Hui Liu
GMGerald Matson
Gerald Matson
Recently, gradient performance and fidelity has become of increasing interest, as the fidelity of the magnetic resonance (MR) image is somewhat dependent on the fidelity of the gradient system. In particular, for high fidelity non-Cartesian imaging, due to non-fidelity of the gradient system, it becomes necessary to know the actual k-space trajectory as opposed to the requested trajectory. In this work we show that, by considering the gradient system as a linear time-invariant system, the gradient impulse response function (GIRF) can be reliably measured to a relatively high degree of accuracy with a simple setup, using a small phantom and a series of simple experiments. It is shown experimentally that the resulting GIRF is able to predict actual gradient performance with a high degree of accuracy. The method captures not only the frequency response but also gradient timing errors and artifacts due to mechanical vibrations of the gradient system. Some discussion is provided comparing the method presented here with other analogous methods, along with limitations of these methods.

26 April 2011 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
HLHui Liu
Hui Liu
GMGerald Matson
Gerald Matson
Although high‐field MRI offers increased signal‐to‐noise, the nonuniform tipping produced by conventional radiofrequency (RF) pulses leads to spatially dependent contrast and suboptimal signal‐to‐noise, thus complicating the interpretation of the MR images. For structural imaging, three‐dimensional sequences that do not make use of frequency‐selective RF pulses have become popular. Therefore, the aim of this research was to develop non‐slice‐selective (NSS) RF pulses with immunity to both amplitude of (excitation) RF field (B1) inhomogeneity and resonance offset. To accomplish this, an optimization routine based on optimal control theory was used to design new NSS pulses with desired ranges of immunity to B1 inhomogeneity and resonance offset. The design allows the phase of transverse magnetization produced by the pulses to vary. Although the emphasis is on shallow tip designs, new designs for 30°, 60°, 90°, and 180° NSS RF pulses are also provided. These larger tip angle pulses are compared with recently published NSS pulses. Evidence is presented that the pulses presented in this article have equivalent performance but are shorter than the recently published pulses. Although the NSS pulses generate higher specific absorption rates and larger magnetization transfer effects than the rectangular pulses they replace, they nevertheless show promise for three‐dimensional MRI experiments at high field. Magn Reson Med, 2011.

31 July 2009 in Journal of Magnetic Resonance
Verified
Journal Article
Closed access
GMGerald Matson
Gerald Matson
KYKarl Young
Karl Young
LKLana G. Kaiser
Lana G. Kaiser

1 December 2017 in Magnetic Resonance Imaging
Verified
Journal Article
Closed access
GMGerald Matson
Gerald Matson