Yong-Jiang LI

Dr. Yong-Jiang LI

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 September 2024 in Frontiers in Endocrinology
Verified
Journal Article
Open access
PDF file
YZYu-Yuan Zhang
Yu-Yuan Zhang
YLYong-Jiang LI
Yong-Jiang LI
CXChun-Dong Xue
Chun-Dong Xue
SLShen Li
Shen Li
ZGZhengnan Gao
Zhengnan Gao
KQKai-Rong Qin
Kai-Rong Qin
Type 2 diabetes mellitus (T2DM) is a chronic metabolic disorder affecting people worldwide. It is characterized by several key features, including hyperinsulinemia, hyperglycemia, hyperlipidemia, and dysbiosis. Epidemiologic studies have shown that T2DM is closely associated with the development and progression of cancer. T2DM-related hyperinsulinemia, hyperglycemia, and hyperlipidemia contribute to cancer progression through complex signaling pathways. These factors increase drug resistance, apoptosis resistance, and the migration, invasion, and proliferation of cancer cells. Here, we will focus on the role of hyperinsulinemia, hyperglycemia, and hyperlipidemia associated with T2DM in cancer development. Additionally, we will elucidate the potential molecular mechanisms underlying their effects on cancer progression. We aim to identify potential therapeutic targets for T2DM-related malignancies and explore relevant directions for future investigation.

7 July 2019 in Micromachines
Verified
Journal Article
Open access
PDF file
XCXiaoming Chen
Xiaoming Chen
YLYong-Jiang LI
Yong-Jiang LI
DHDan Han
Dan Han
HZHuichao Zhu
Huichao Zhu
CXChundong Xue
Chundong Xue
Kai-Rong QinKai-Rong Qin
Kai-Rong Qin
Sweat collection and real time monitoring of sweat rate play essential roles in physiology monitoring and assessment of an athlete’s performance during exercise. In this paper, we report a micropump for sweat simulant collection based on the capillary–evaporation effect. An electrochemical sensor is integrated into the micropump, which monitors the flow rate in real-time by detecting the current using three electrodes. The evaporation rate from micropore array, equivalent to the sweat rate, was theoretically and numerically investigated. The designed micropump yields the maximum collection rate as high as 0.235 μ L/min. In addition, the collection capability of the micropump was validated experimentally; the flow rate through the microchannel was further detected in real-time with the electrochemical sensor. The experimental maximum collection rate showed good consistency with the theoretical data. Our proposed device shows the potential for sweat collection and real-time monitoring of sweat rate, which is a promising candidate for being a wearable platform for real-time physiology and performance monitoring during exercise.

16 February 2019 in Micromachines
Verified
Journal Article
Open access
PDF file
YLYong-Jiang LI
Yong-Jiang LI
YYYu-Nong Yang
Yu-Nong Yang
HZHai-Jun Zhang
Hai-Jun Zhang
CXChundong Xue
Chundong Xue
DZDe-Pei Zeng
De-Pei Zeng
Kai-Rong QinKai-Rong Qin
Kai-Rong Qin
The biomechanical properties of single cells show great potential for early disease diagnosis and effective treatments. In this study, a microfluidic device was developed for quantifying the mechanical properties of a single cell. Micropipette aspiration was integrated into a microfluidic device that mimics a classical Wheatstone bridge circuit. This technique allows us not only to effectively alter the flow direction for single-cell trapping, but also to precisely control the pressure exerted on the aspirated cells, analogous to the feature of the Wheatstone bridge that can precisely control bridge voltage and current. By combining the micropipette aspiration technique into the microfluidic device, we can effectively trap the microparticles and Hela cells as well as measure the deformability of cells. The Young’s modulus of Hela cells was evaluated to be 387 ± 77 Pa, which is consistent with previous micropipette aspiration studies. The simplicity, precision, and usability of our device show good potential for biomechanical trials in clinical diagnosis and cell biology research.

11 September 2022 in Talanta
Verified
Journal Article
Closed access
JNJing-Tong Na
Jing-Tong Na
CXChun-Dong Xue
Chun-Dong Xue
YWYan-Xia Wang
Yan-Xia Wang
YLYong-Jiang LI
Yong-Jiang LI
YWYu Wang
Yu Wang
Kai-Rong QinKai-Rong Qin
Kai-Rong Qin

1 November 2023 in Electrophoresis
Verified
Journal Article
Closed access
SLShan‐Shan Li
Shan‐Shan Li
CXChundong Xue
Chundong Xue
YLYong-Jiang LI
Yong-Jiang LI
XCXiao‐Ming Chen
Xiao‐Ming Chen
YZYan Zhao
Yan Zhao
KQKai‐Rong Qin
Kai‐Rong Qin

30 September 2021 in Polymers
Verified
Journal Article
Open access
PDF file
YLYong-Jiang LI
Yong-Jiang LI
LXLei Xiao
Lei Xiao
ZWZian Wang
Zian Wang
KCKejie Chen
Kejie Chen
CXChundong Xue
Chundong Xue
Kai-Rong QinKai-Rong Qin
Kai-Rong Qin
Endovascular glue embolization is a minimally invasive technique used to selectively reduce or block the blood supply to specific targeted vessels. Cyanoacrylate glues, mixed with radiopaque iodized oil, have been widely used for vascular embolization owing to their rapid polymerization rate, good penetration ability and low tissue toxicity. Nevertheless, in clinical practice, the selection of the glue–oil proportion and the manual injection process of mixtures are mostly based on empirical knowledge of operators, as the crucial physicochemical effect of polymerization kinetics has rarely been quantitatively investigated. In this study, the Raman spectroscopy is used for studying the polymerization kinetics of n-butyl-cyanoacrylate-based glues mixed with an iodized oil. To simulate the polymerization process during embolization, glue–oil mixtures upon contact with a protein ionic solution mimicking blood plasma are manually constructed and their polymerization kinetics are systematically characterized by Raman spectroscopy. The results demonstrate the feasibility of Raman spectroscopy in the characterization of polymerization kinetics of cyanoacrylate-based embolic glues. The polymerization process of cyanoacrylate-based mixtures consists of a fast polymerization phase followed by a slow phase. The propagation velocity and polymerization time primarily depend on the glue concentrations. The commonly used 50% mixture polymerizes 1 mm over ∼21.8 s, while it takes ∼51 min to extend to 5 mm. The results provide essential information for interventional radiologists to help them understand the polymerization kinetics of embolic glues and thus regulate the polymerization rate for effective embolization.