A retaining wall using batter piles has been developed and studied to improve existing earth-retaining structures at Pusan National University. The earth-retaining method is a temporary excavation method using an integrated system of front supports and batter piles. The batter piles connected to the front supports significantly reduce the earth pressure acting on the front supports by distributing it to batter piles to increase structural stability. In this study, the existence of batter piles, the fixity of the tips of front supports or batter piles, the spacing between batter piles, and the verticality of front supports are varied across model tests. The lateral displacement of the earth-retaining wall decreased by approximately 40% and 15% for the existence and fixity of batter piles, respectively. The applicability of the earth-retaining method using batter piles has been verified with finite element analysis and field test execution in clay ground.
The in situ application of micropiles has gradually increased in confined spaces of complex cities because the micropile has many advantages, such as low noise and vibration and compact machine size. Using the results of experimental analyses, this study purposes to improve the reinforcement efficiency of micropiles by recommending the most effective pattern and design method for installing them. In this study, model tests were carried out to understand the ground reinforcement effect induced by the mechanical interaction between the micropile and soil. The micropiles were installed in the soil underneath footings. Factors such as micropile diameter (D), micropile length (L), and number (n) of micropiles were considered as variables in the model tests. The positive effect of grouping micropiles and the confining effect of the ground increased the bearing capacity of a single micropile by about 2.27–2.60 times and 1.10–1.33 times, respectively.
7 October 2022 in KSCE Journal of Civil Engineering
Friction anchors are gaining popularity in civil structures. However, the bond length can be increased to use the friction between the ground and friction anchor body. They are often bonded deep in the ground and fixed to the bedrock; this causes problems, including the anchor overlapping the underground structure or invading the lower part of another structure when anchors are installed in downtown sites. Herefore, combination anchors that combine the advantages of plate anchors that resist uplift because of the ground’s bearing capacity with a friction-type anchor have gained attention. However, the ground failure mechanism of plate anchors applied to combination-type anchors has not been accurately analyzed; therefore, various theoretical anchor uplift capacity formulas have been proposed. A model test was performed in this study by forming a sandy ground in a state of plane strain to verify the uplift capacity of the plate anchor installed at a shallow depth and ground failure mechanismPhotos obtained from experiment were evaluated to analyze the shape of the ground failure of the plate anchor. Furthermore, by classifying the depth of the installed anchor, an equation for calculating the ultimate uplift capacity of the plate anchor was proposed according to the classified depth. A model test was performed in this study based on the formation of a sandy ground in a state of plane strain to verify the uplift capacity of the plate anchor installed at a shallow depth and ground failure mechanism. Photos obtained from experimental tests were evaluated to analyze the shape of the ground failure of the plate anchor. Furthermore, by classifying the depth of the installed anchor, an equation for calculating the ultimate uplift capacity of the plate anchor was also proposed according to the classified depth.