Ultra high field MR imaging (≥7 T) of deeply located targets in the body is facing some radiofrequency‐field related challenges: interference patterns, reduced penetration depth, and higher Specific Absorbtion Ratio (SAR) levels. These can be alleviated by redesigning the elements of the transmit or transceive array. This is because at these high excitation field (B1) frequencies, conventional array element designs may have become suboptimal. In this work, an alternative design approach is presented, regarding coil array elements as antennas. Following this approach, the Poynting vector of the element should be oriented towards the imaging target region. The single‐side adapted dipole antenna is a novel design that fulfills this requirement. The performance of this design as a transmit coil array element has been characterized by comparison with three other, more conventional designs using finite difference time domain (FDTD) simulations and B measurements on a phantom. Results show that the B level at the deeper regions is higher while maintaining relatively low SAR levels. Also, the B field distribution is more symmetrical and more uniform, promising better image homogeneity. Eight radiative antennas have been combined into a belt‐like surface array for prostate imaging. T1‐weighted (T1W) and T2‐weighted (T2W) volunteer images are presented along with B measurements to demonstrate the improved efficiency. Magn Reson Med, 2011.
Ketones represent an important alternative fuel for the brain under glucose hypo-metabolic conditions induced by neurological diseases or aging, however their metabolic consequences in healthy brain remain unclear. Here we report that ketones can increase the redox NAD+/NADH ratio in the resting brain of healthy young adults. As NAD is an important energetic and signaling metabolic modulator, these results provide mechanistic clues on how nutritional ketosis might contribute to the preservation of brain health.
Patient‐specific radiofrequency shimming in high‐field MRI strengthens the need for online, patient‐specific specific absorption rate (SAR) monitoring. Numerical simulation is currently most effective for this purpose but may require a patient‐specific dielectric model. To investigate whether a generic model may be combined with a safety factor to account for variation within the population, generic SAR behavior is studied for 7T MRI of the head. For six detailed head models, radiofrequency fields were simulated for an eight‐channel parallel transmit array. SAR behavior is studied through comparison of the eigenvalues/eigenvectors of the local Q‐matrices. Furthermore, numerical radiofrequency shimming experiments without and with SAR constraints were performed where SAR during optimization was evaluated on a generic model. In both cases, the ability of different generic models to predict actual SAR levels was evaluated. The largest eigenvalue distribution is comparable between models. Radiofrequency shimming without constraints improves the |B| homogeneity while the SAR increases substantially. Imposing constraints on SAR during optimization, estimating SAR on a generic model, was effective. A safety factor of 1.4 was found to be sufficient. Generic SAR behavior makes a generic head model a practical alternative to patient‐specific models and allows effective |B| shimming with SAR constraints. Magn Reson Med, 2013.
Purpose: Multichannel receive arrays provide high SNR and parallel‐imaging capabilities, while transmit‐only dipole arrays have been shown to achieve a large coverage of the whole‐brain including the cerebellum. The aim of this study was to develop and characterize the performances of a 32‐channel receive‐only loop array combined with an 8‐channel dipole coil array at 7T for the first time.Methods: The 8Tx‐dipoles/32Rx‐loops coil array was characterized by the SNR, g‐factors, noise correlation matrix, accelerated image quality, and maps, and compared with a commercial 1Tx‐birdcage/32Rx‐loops array. Simulated and measured maps were shown for the 8Tx‐dipoles/32Rx‐loops coil array and compared with the 8Tx/Rx dipole array.Results: The in‐house built 32‐channel receive coil demonstrated a large longitudinal coverage of the brain, particularly the upper neck area. G‐factors and accelerated MR acquisitions demonstrated robust performances up to R = 4 in 2D, and R = 8 (4 × 2) in 3D. A 83% increase in SNR was measured over the cerebellum with the in‐house built 8Tx/32Rx coil array compared to the commercial 1Tx/32Rx, while similar performances were obtained in the cerebral cortex.Conclusions: The combined 32‐channel receive/8‐channel transmit coil array demonstrated high transmit‐receive performances compared to the commercial receive array at 7T, notably in the cerebellum. We conclude that in combination with parallel transmit capabilities, this coil is particularly suitable for whole‐brain MR studies at 7T.