Yaobin Yin

Dr. Yaobin Yin


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 July 2017 in BMC Neuroscience
Verified
Journal Article
Open access
PDF file
LSLena Stenberg
Lena Stenberg
MSMaria Stößel
Maria Stößel
GRGiulia Ronchi
Giulia Ronchi
Stefano GeunaStefano Geuna
Stefano Geuna
YYYaobin Yin
Yaobin Yin
KHKirsten Haastert-Talini
Kirsten Haastert-Talini
Delayed reconstruction of transection or laceration injuries of peripheral nerves is inflicted by a reduced regeneration capacity. Diabetic conditions, more frequently encountered in clinical practice, are known to further impair regeneration in peripheral nerves. Chitosan nerve guides (CNGs) have recently been introduced as a new generation of medical devices for immediate peripheral nerve reconstruction. Here, CNGs were used for 45 days delayed reconstruction of critical length 15 mm rat sciatic nerve defects in either healthy Wistar rats or diabetic Goto-Kakizaki rats; the latter resembling type 2 diabetes. In short and long-term investigations, we comprehensively analyzed the performance of one-chambered hollow CNGs (hCNGs) and two-chambered CNGs (CFeCNGs) in which a chitosan film has been longitudinally introduced. Additionally, we investigated in vitro the immunomodulatory effect provided by the chitosan film. Both types of nerve guides, i.e. hCNGs and CFeCNGs, enabled moderate morphological and functional nerve regeneration after reconstruction that was delayed for 45 days. These positive findings were detectable in generally healthy as well as in diabetic Goto-Kakizaki rats (for the latter only in short-term studies). The regenerative outcome did not reach the degree as recently demonstrated after immediate reconstruction using hCNGs and CFeCNGs. CFeCNG-treatment, however, enabled tissue regrowth in all animals (hCNGs: only in 80% of animals). CFeCNGs did further support with an increased vascularization of the regenerated tissue and an enhanced regrowth of motor axons. One mechanism by which the CFeCNGs potentially support successful regeneration is an immunomodulatory effect induced by the chitosan film itself. Our in vitro results suggest that the pro-regenerative effect of chitosan is related to the differentiation of chitosan-adherent monocytes into pro-healing M2 macrophages. No considerable differences appear for the delayed nerve regeneration process related to healthy and diabetic conditions. Currently available chitosan nerve grafts do not support delayed nerve regeneration to the same extent as they do after immediate nerve reconstruction. The immunomodulatory characteristics of the biomaterial may, however, be crucial for their regeneration supportive effects.

4 January 2021 in BMC Musculoskeletal Disorders
Verified
Journal Article
Open access
PDF file
YYYaobin Yin
Yaobin Yin
YWYanqing Wang
Yanqing Wang
ZWZhilong Wang
Zhilong Wang
WQWenrui Qu
Wenrui Qu
WTWen Tian
Wen Tian
SCShanlin Chen
Shanlin Chen
Background: Restoration of joint congruity is an important factor for the prevention of subsequent arthritis in patients with Bennett’s fracture. Surgical treatment of Bennett’s fracture is thus generally recommended for displaced intra-articular fractures to the proximal aspect of the thumb metacarpal. Fluoroscopic examination is used to evaluate the adequacy of closed reduction after pinning of Bennett’s fracture. The purpose of this study was to determine the accuracy of fluoroscopy to determine the reduction of Bennett’s fractures.Methods: A model was created, to mimic a Bennett’s fracture utilizing ten fresh-frozen cadaveric hands. An oblique cut was made in the proximal aspect of the thumb metacarpal using an oscillating saw. The small oblique fragment involved 1/4–1/3 of the joint surface was then shifted in position creating a step-off or gap at the fracture site. An anatomical reduction model, gap models (1 mm, 2 mm, 3 mm), and step-off models (1 mm, 2 mm, 3 mm) were created using percutaneous fixation with two 1.0 mm Kirschner wires for each cadaveric hand. Fluoroscopic assessment then took place and was reviewed by 2 attending hand surgeons blinded to the actual position. Their estimated fluoroscopic position was then compared to the actual displacement.Results: The step-off and gap on fluoroscopic examination showed a significant difference compared to the step-off and gap from direct visualization. The frequency of underestimation for the 3 mm displacement models from the fluoroscopic examination was 60%. The frequency for overestimated was 9% for the models in which displacement was within 2 mm (0, 1, 2 mm).Conclusions: The assessment of articular gap and step-off using PA (postero-anterior), AP (antero-posterior), and lateral view of fluoroscopic examination is not accurate as compared to the examination by direct visualization. Surgeons need to be aware that PA, AP and lateral view of fluoroscopic examination alone may not be sufficient to judge the final position of a reduced Bennett’s fracture. Other methods such as live fluoroscopy in multiple different planes, 3-dimensional fluoroscopy or arthroscopic examination should be considered.

31 May 2018 in Scientific Reports
Verified
Journal Article
Open access
PDF file
YYYaobin Yin
Yaobin Yin
JJJianguang Ji
Jianguang Ji
YBYan Borné
Yan Borné
YWYanqing Wang
Yanqing Wang
JZJunhui Zhao
Junhui Zhao
WTWen Tian
Wen Tian
Heart–hand syndrome (HHS) is a clinically and genetically heterogeneous disorder characterized by the co-occurrence of a congenital cardiac disease and an upper limb malformation. This study revealed the clinical and epidemiological features of HHS in China. The study was based on patients with congenital upper limb malformation treated in Beijing Ji Shui Tan hospital from October 1st, 2013 to October 1st, 2016. We reviewed the patients’ medical records and identified patients with abnormal ultrasonic cardiogram and/or electrocardiogram (ECG). A total of 1462 patients (910 male and 552 female) were identified to be treated for congenital upper limb malformation. Among them, 172 (11.8%) had abnormal ultrasonic cardiogram and/or ECG. Abnormal heart structure were discovered in 121 patients and 51 patients had abnormal ECG. The most common type of abnormal heart structure was tricuspid regurgitation (53/121, 43.8%), while the most common abnormal ECG was wave patterns (22/51, 43.1%). This hospital-based study suggests that the rate of congenital heart disease is high in patients treated for congenital upper extremity malformation in China. Surgeons and anesthetists should be aware of the comorbidity and preoperational examination of congenital heart diseases is highly needed to avoid complications during operation.

6 November 2024 in Journal of Orthopaedic Surgery and Research
Verified
Journal Article
Open access
PDF file
ZWZhixin Wang
Zhixin Wang
BLBo Liu
Bo Liu
ZYZhe Yi
Zhe Yi
KXKe Xu
Ke Xu
SJShijie Jia
Shijie Jia
YYYaobin Yin
Yaobin Yin
Background: The purpose of this study is to explore the feasibility and accuracy of a robot-assisted technique in four-corner fusion compared with traditional freehand operation. Methods: Twenty cadaver specimens were randomly assigned to the robot-assisted group and freehand groups. Three screws were placed percutaneously to fix the capitate-lunate joint, lunate-triquetrum joint, and triquetrum-hamate-capitate joint in each specimen by robot-assisted or freehand technique. The offset between the actual and planned screw positions was determined by merging the images of intraoperative and postoperative CT scans in the robot-assisted group. The centrality of the screw, time-consuming, drilling attempts, and radiation exposure were compared between the two groups. Results: The mean offset between the actual and planned screw position was 1.09 (SD: 0.56) mm. The offset at the start point of the screw was significantly lower than that at the endpoint. There was no significant difference in the centrality of the screws, surgical time between the two groups. The number of drilling attempts and the radiation dose received by surgeons were significantly lower in the robot-assisted group. Conclusions: Although there was no significant difference in screw centrality between the two groups, the slight offset between the actual and planned screw positions confirmed the feasibility of the robot-assisted technique in four-corner fusion. The robot-assisted technique has advantages in reducing the difficulty of surgery and protecting the surgeon from exposure to large doses of radiation.

19 April 2026 in Orthopaedic Surgery
Verified
Journal Article
Open access
SJShijie Jia
Shijie Jia
ZXZiyue Xiang
Ziyue Xiang
ZYZhe Yi
Zhe Yi
SCShanlin Chen
Shanlin Chen
BLBo Liu
Bo Liu
YYYaobin Yin
Yaobin Yin
Objective: Distal radioulnar joint (DRUJ) instability is commonly assessed clinically via physical examination, such as a ballottement test, which evaluates palmar‐dorsal translation of the radius relative to the ulna. However, the normal physiological range of translation and the factors influencing it remain poorly defined, limiting the test's diagnostic precision. This study aimed to quantify the normal range of DRUJ translation and identify its associated factors in a healthy population. Methods: Healthy adult participants were recruited between January 1, 2025, and April 30, 2025. Data on occupation, gender, age, height, weight, handedness, wrist circumference, forearm length, and grip strength were recorded. A custom‐designed device was used to measure the palmar, dorsal, and combined DRUJ translations in forearm pronation, supination, and neutral positions. Univariate and multivariate analyses were performed to identify factors influencing translation. Results: The mean (±SD) combined DRUJ translation was 11.9 ± 4.2 mm in pronation, 12.4 ± 3.9 mm in supination, and 13.3 ± 4.6 mm in the neutral position. Significant side‐to‐side differences were observed for all translations in pronation and for both palmar and dorsal translations in the neutral position. No significant side‐to‐side difference was found in supination. Compared to pronation and supination, combined and palmar translations were significantly greater in the neutral position. Conversely, dorsal translation was greatest in supination. Multivariate analysis revealed that combined DRUJ translation in supination was significantly influenced by grip strength, forearm length, weight, and age. Conclusion: Our findings establish reference values for DRUJ translation and demonstrate that it is influenced by forearm position and multiple factors. To improve the clinical utility of the ballottement test, we recommend performing it in forearm supination while comparing both limbs. Specifically, combined DRUJ translation with forearm supinated is significantly affected by grip strength, forearm length, weight, and age. Level of Evidence: 3.