Most of the mechanical systems in industries are made to run through induction motors (IM). To maintain the performance of the IM, earlier detection of minor fault and continuous monitoring (CM) are required. Among IM faults, bearing faults are considered as indispensable because of its high probability incidence nature. CM mainly depends upon signal processing and fault detection techniques. In recent decades, various methods have been involved in detecting the bearing fault using machine learning (ML) algorithms. Additionally, the role of artificial intelligence (AI), a growing technology, has also been used in fault diagnosis of IM. Taking the necessity of minor fault detection and the detailed study about the role of ML and AI to detect the bearing fault, the present study is performed. A comprehensive study is conducted by considering various diagnosis methods from ML and AI for detecting a minor bearing fault (hole and scratch). This study helps in understanding the difference between the diagnosis approach and their effectiveness in detecting an IM bearing fault. It is accomplished through FFT (fast Fourier transform) analysis of the load current and the extracted features are used to train the algorithm. The application is extended by comparing the result of ML and AI, and then explaining the specific purpose of use.
Induction motors are becoming crucial components in numerous industries. The daily usage of induction motors creates the demand for proper maintenance and slight fault detection to avoid serious damage to the induction motor and the shutdown of industries. Among the various kinds of faults in induction motors, bearing faults, broken rotor bar faults, and short-circuit insulation faults are the most common. Thus, detection and classification of these faults in initial stage are attracting great attention. There are conventional methods for detecting such faults, such as the vibration method for bearing faults, the self-organizing map in the case of broken rotor bar faults, and motor current signature analysis for short-circuit insulation faults. From an industrial point of view, diagnosis methods that can classify all these major faults are required. However, reports on the detection and classification of these faults in initial stage using common diagnosis methods are scarce. In this paper, all three kinds of notable faults in an induction motor were artificially induced, and diagnoses using motor stator current spectral features and the rotation speed of the motor were performed. The diagnosis was accomplished using an auto-tunable and arbitrary featured support vector machine algorithm. Although the faults were minor, a high accuracy rate was obtained. The capability to classify the faults and the high diagnosis accuracy prove the robustness and high sensitivity of the method, enabling its practical applications in industries.
3 May 2018 in IEEE Transactions on Industrial Electronics
Bearing faults are a major source of failure in induction motor and early detection of fault becomes necessary because of its industrial application. A range of analytical methods has been used to detect, identify, and diagnose bearing faults, including vibrational analysis. Most analyses have used pitting as the fault, whereas in industrial environments, scratches are a more common problem. The present study investigated such scratches, applying two types of fault analysis: fault progression and fault orientation. A Support Vector Machine (SVM) algorithm was used to classify and diagnose the different types of bearing fault. The frequency domain features obtained from a fast Fourier transform (FFT) of the load current were used to train the SVM algorithm. The proposed diagnostic method was tested experimentally using induced outer race faults under different load conditions. The method was shown to be successful in diagnosing faults, suggesting potential applications in real industrial settings.
Various industrial fields use motors as key power sources, and their importance is increasing. In motor manufacturing, various tests are conducted for each motor before shipping. The no-load test is one such test, in which, for instance, the current flowing into the motor and temperature of the bearing is measured to confirm whether they are within specific values. Reducing labor, cost, and time in identifying an initially defective product requires a simple and reliable method. This study proposes a new diagnosis to identify the motor conditions based on the rotating sound of the motor in the no-load test. First, the rotating sounds of motors were measured using several healthy motors and motors with faults. Second, their sound characteristics were analyzed, and it was found that the characteristic signals appeared in a specific frequency range periodically. Then, considering these phenomena, a diagnostic method based on deep learning was proposed to judge the faults using long short-term memory (LSTM). Finally, the effectiveness of the proposed method was verified through experiments.
Induction motors are widely used in industry and are essential to industrial processes. The faults in motors lead to high repair costs and cause financial losses resulting from unexpected downtime. Early detection of faults in induction motors has become necessary and critical in reducing costs. Most motor faults are caused by bearing failure. Machine learning-based diagnostic methods are proposed in this study. These methods use effective features. First, load currents of healthy and faulty motors are measured while the rotating speed is changing continuously. Second, experiments revealed the relationship between the magnitude of the amplitude of specific signals and the rotating speed, and the rotating speed is treated as a new feature. Third, machine learning-based diagnoses are conducted. Finally, the effectiveness of machine learning-based diagnostic methods is verified using experimental data.
2 July 2008 in IEEE Transactions on Power Delivery
The countermeasure against lightning faults is one of the most decisive factors in designing a transmission line in a high grounding resistance area. The higher the footing resistance is, the higher the resulting lightning surge voltage borne by the insulator string is. But it is practically not so easy to decrease the tower footing resistance. Lightning arresters for the transmission line have been developed and are already in successful service. However, the application effect of line arresters to the tower of high footing resistance has not been studied yet. This paper describes the results of computer calculation regarding the application effect of transmission-line arresters assuming typical parameters of the 77-kV line in Japan. As a result, the line arresters can effectively prevent the lightning faults in an area of high footing resistance.