Subhamoy Mandal

Dr. Subhamoy Mandal

Maxer Endoscopy GmbH, Tuttlingen, Germany and Technical University of Munich, Munich, Germany
orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 September 2015 in European Radiology
Verified
Journal Article
Closed access
PDF file
VEVladimir Ermolayev
Vladimir Ermolayev
XDXose Luis Dean-Ben
Xose Luis Dean-Ben
SMSubhamoy Mandal
Subhamoy Mandal
VNVasilis Ntziachristos
Vasilis Ntziachristos
DRDaniel Razansky
Daniel Razansky

12 April 2016 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Open access
SMSubhamoy Mandal
Subhamoy Mandal
XDXose Luis Dean-Ben
Xose Luis Dean-Ben
DRDaniel Razansky
Daniel Razansky
Segmentation of biomedical images is essential for studying and characterizing anatomical structures as well as for detection and evaluation of tissue pathologies. Segmentation has been further shown to enhance the reconstruction performance in many tomographic imaging modalities by accounting for heterogeneities in the excitation field and tissue properties in the imaged region. This is particularly relevant in optoacoustic tomography, where discontinuities in the optical and acoustic tissue properties, if not properly accounted for, may result in deterioration of the imaging performance. Efficient segmentation of optoacoustic images is often hampered by the relatively low intrinsic contrast of large anatomical structures, which is further impaired by the limited angular coverage of some commonly employed tomographic imaging configurations. Herein, we analyze the performance of active contour models for boundary segmentation in cross-sectional optoacoustic tomography. The segmented mask is employed to construct a two compartment model for the acoustic and optical parameters of the imaged tissues, which is subsequently used to improve accuracy of the image reconstruction routines. The performance of the suggested segmentation and modeling approach are showcased in tissue-mimicking phantoms and small animal imaging experiments.

24 September 2018 in IEEE Pulse
Verified
Journal Article
Closed access
SMSubhamoy Mandal
Subhamoy Mandal
AGAaron B. Greenblatt
Aaron B. Greenblatt
JAJingzhi An
Jingzhi An
Artificial intelligence (AI) and machine learning (ML) have influenced medicine in myriad ways, and medical imaging is at the forefront of technological transformation. Recent advances in AI/ML fields have made an impact on imaging and image analysis across the board, from microscopy to radiology. AI has been an active field of research since the 1950s; however, for most of this period, algorithms achieved subhuman performance and were not broadly adopted in medicine. Recent enhancements for computational hardware is enabling researchers to revisit old AI algorithms and experiment with new mathematical ideas. Researchers are applying these methods to a broad array of medical technologies, ranging from microscopic image analysis to tomographic image reconstruction and diagnostic planning.

1 September 2014 in Photoacoustics
Verified
Journal Article
Open access
SMSubhamoy Mandal
Subhamoy Mandal
ENElena Nasonova
Elena Nasonova
XDXosé Luís Deán-Ben
Xosé Luís Deán-Ben
DRDaniel Razansky
Daniel Razansky
In tomographic optoacoustic imaging, multiple parameters related to both light and ultrasound propagation characteristics of the medium need to be adequately selected in order to accurately recover maps of local optical absorbance. Speed of sound in the imaged object and surrounding medium is a key parameter conventionally assumed to be uniform. Mismatch between the actual and predicted speed of sound values may lead to image distortions but can be mitigated by manual or automatic optimization based on metrics of image sharpness. Although some simple approaches based on metrics of image sharpness may readily mitigate distortions in the presence of highly contrasting and sharp image features, they may not provide an adequate performance for smooth signal variations as commonly present in realistic whole-body optoacoustic images from small animals. Thus, three new hybrid methods are suggested in this work, which are shown to outperform well-established autofocusing algorithms in mouse experiments in vivo.

14 January 2019 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
JJJayaprakash Jeyaraju
Jayaprakash Jeyaraju
SMSubhamoy Mandal
Subhamoy Mandal
DRDaniel Razansky
Daniel Razansky
VNVasilis Ntziachristos
Vasilis Ntziachristos
Objective: Optoacoustic (photoacoustic) tomography is aimed at reconstructing maps of the initial pressure rise induced by the absorption of light pulses in tissue. In practice, due to inaccurate assumptions in the forward model, noise and other experimental factors, the images are often afflicted by artifacts, occasionally manifested as negative values. The aim of the work is to develop an inversion method which reduces the occurrence of negative values and improves the quantitative performance of optoacoustic imaging. Methods: We present a novel method for optoacoustic tomography based on an entropy maximization algorithm, which uses logarithmic regularization for attaining nonnegative reconstructions. The reconstruction image quality is further improved using structural prior based fluence correction. Results: We report the performance achieved by the entropy maximization scheme on numerical simulation, experimental phantoms and in-vivo samples. Conclusion: The proposed algorithm demonstrates superior reconstruction performance by delivering non-negative pixel values with no visible distortion of anatomical structures. Significance: Our method can enable quantitative optoacoustic imaging, and has the potential to improve pre-clinical and translational imaging applications.

9 August 2021 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
SPSouradip Paul
Souradip Paul
SMSubhamoy Mandal
Subhamoy Mandal
MSMayanglambam Suheshkumar Singh
Mayanglambam Suheshkumar Singh
The delay-and-sum (DAS) algorithm is widely used for beamforming in linear array photoacoustic (PA) imaging systems and is characterized by fast execution. However, these algorithms suffer from various drawbacks, such as low resolution, low contrast, high sidelobe artifacts, and lack of visual coherence. More recently, adaptive weighting was introduced to improve the reconstruction image quality. Unfortunately, the existing state-of-the-art adaptive beamforming algorithms are computationally expensive and do not consider the specific noise characteristics of the acquired ultrasonic signal. In this article, we present a new adaptive weighting factor named the variational coherence factor (VCF), which takes into account the noise level variations of radio frequency data. The proposed technique provides superior results in terms of image resolution, sidelobe reduction, signal-to-noise ratio (SNR), and contrast level improvement. The quantitative results of the microsphere phantom imaging show that the proposed VCF-assisted DAS method leads to 55% and 25% improvements in full-width-at-half-maximum (FWHM) and 57% and 32% improvement in SNR, respectively, compared to the state-of-the-art DAS-based methods. The results demonstrate that the proposed method can effectively improve the reconstructed image quality and deliver satisfactory imaging performance even with a limited number of sensor elements. The proposed method can potentially reduce the instrumentation cost of the PA imaging system and contribute toward the clinical translation of the modality.