andrew webb

andrew webb

orcid

Research Focus & Metrics

Academic Career Length

36Years (1991-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 August 2011 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
WTWouter M. Teeuwisse
Wouter M. Teeuwisse
WBWyger Brink
Wyger Brink
AWandrew webb
andrew webb
The use of high‐permittivity materials has been shown to be an effective method for increasing transmit and receive sensitivity in areas of low‐signal intensity in the brain at high field. Results in this article show that the use of these materials does not increase the intercoil coupling for a phased array receive coil, does not have any detrimental effects on the B0 homogeneity within the brain, and does not affect the specific absorption rate distribution within the head. Areas of the brain close to the pads exhibit significant increases (>100%) in transmit field efficiency, but areas further away show a less pronounced (∼10%) decrease due to the homogenization of the transmit field and the loss introduced by the dielectric pads. Magn Reson Med, 2012.

5 July 2020 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
TOThomas O’rEilly
Thomas O’rEilly
WTWouter M. Teeuwisse
Wouter M. Teeuwisse
DGDanny de Gans
Danny de Gans
KKKirsten Koolstra
Kirsten Koolstra
AWandrew webb
andrew webb
Purpose: To design a low‐cost, portable permanent magnet‐based MRI system capable of obtaining in vivo MR images within a reasonable scan time.Methods: A discretized Halbach permanent magnet array with a clear bore diameter of 27 cm was designed for operation at 50 mT. Custom‐built gradient coils, RF coil, gradient amplifiers, and RF amplifier were integrated and tested on both phantoms and in vivo.Results: Phantom results showed that the gradient nonlinearity in the y‐direction and z‐direction was less than 5% over a 15‐cm FOV and did not need correcting. For the x‐direction, it was significantly greater, but could be partially corrected in postprocessing. Three‐dimensional in vivo scans of the brain of a healthy volunteer using a turbo spin‐echo sequence were acquired at a spatial resolution of 4 × 4 × 4 mm in a time of about 2 minutes. The T1‐weighted and T2‐weighted scans showed a good degree of tissue contrast. In addition, in vivo scans of the knee of a healthy volunteer were acquired at a spatial resolution of about 3 × 2 × 2 mm within 12 minutes to show the applicability of the system to extremity imaging.Conclusion: This work has shown that it is possible to construct a low‐field MRI unit with hardware components costing less than 10 000 Euros, which is able to acquire human images in vivo within a reasonable data‐acquisition time. The system has a high degree of portability with magnet weight of approximately 75 kg, gradient and RF amplifiers each 15 kg, gradient coils 10 kg, and spectrometer 5 kg.

27 January 2012 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
WTW. M. Teeuwisse
W. M. Teeuwisse
WBWyger Brink
Wyger Brink
KHK. N. Haines
K. N. Haines
AWandrew webb
andrew webb
High permittivity “dielectric pads” have been shown to increase image quality at high magnetic fields in regions of low radiofrequency transmit efficiency. This article presents a series of electromagnetic simulations to determine the effects of pad size and geometry, relative permittivity value, as well as thickness on the transmit radiofrequency fields for neuroimaging at 7 T. For a 5‐mm thick pad, there is virtually no effect on the transmit field for relative permittivity values lower than ∼90. Significant improvements are found for values between 90 and ∼180. If the relative permittivity is increased above ∼180 then areas of very low transmit efficiency are produced. For a 1‐cm thick pad, the corresponding numbers are ∼60 and ∼120, respectively. Based upon the findings, a new material (barium titanate, relative permittivity ∼150) is used to produce thin (∼5 mm) dielectric pads which can easily be placed within a standard receive head array. Experimental measurements of transmit sensitivities, as well as acquisition of T2‐ and T‐weighted images show the promise of this approach. Magn Reson Med, 2012.

1 October 2019 in Journal of Magnetic Resonance
Verified
Journal Article
Closed access
TOT. O'REilly
T. O'REilly
WTW.M. Teeuwisse
W.M. Teeuwisse
AWandrew webb
andrew webb

16 November 2022 in NMR in Biomedicine
Verified
Journal Article
Closed access
UAUdunna Anazodo
Udunna Anazodo
JNJinggang J. Ng
Jinggang J. Ng
BEBoaz Ehiogu
Boaz Ehiogu
JOJohnes Obungoloch
Johnes Obungoloch
AFAbiodun Fatade
Abiodun Fatade
T(the Consortium for Advancement of MRI Education and Research in Africa (CAMERA)
the Consortium for Advancement of MRI Education and Research in Africa (CAMERA)

10 May 2017 in Scientific Reports
Verified
Journal Article
Open access
PDF file
RSRita Schmidt
Rita Schmidt
ASAlexey Slobozhanyuk
Alexey Slobozhanyuk
PBPavel Belov
Pavel Belov
AWandrew webb
andrew webb
Developments in metamaterials and related structures such as metasurfaces have opened up new possibilities in designing materials and devices with unique properties. Here we report a new hybrid metasurface structure, comprising a two-dimensional metamaterial surface and a very high permittivity dielectric substrate, that has been designed to enhance the local performance of an ultra-high field MRI scanner. This new flexible and compact resonant structure is the first metasurface which can be integrated with multi-element close-fitting receive coil arrays that are used for all clinical MRI scans. We demonstrate the utility of the metasurface acquiring in-vivo human brain images and proton MR spectra with enhanced local sensitivity on a commercial 7 Tesla system.