Charusluk Viphavakit

Dr. Charusluk Viphavakit

Chulalongkorn University, Bangkok, Krung Thep Maha Nakhon, Thailand
orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 January 2023 in Biosensors
Verified
Journal Article
Open access
PDF file
Akhilesh Kumar PathakAkhilesh Kumar Pathak
Akhilesh Kumar Pathak
Kankan SwargiaryKankan Swargiary
Kankan Swargiary
NKNuntaporn Kongsawang
Nuntaporn Kongsawang
PJPannathorn Jitpratak
Pannathorn Jitpratak
NANoppasin Ajchareeyasoontorn
Noppasin Ajchareeyasoontorn
Charusluk ViphavakitCharusluk Viphavakit
Charusluk Viphavakit
In general, volatile organic compounds (VOCs) have a high vapor pressure at room temperature (RT). It has been reported that all humans generate unique VOC profiles in their exhaled breath which can be utilized as biomarkers to diagnose disease conditions. The VOCs available in exhaled human breath are the products of metabolic activity in the body and, therefore, any changes in its control level can be utilized to diagnose specific diseases. More than 1000 VOCs have been identified in exhaled human breath along with the respiratory droplets which provide rich information on overall health conditions. This provides great potential as a biomarker for a disease that can be sampled non-invasively from exhaled breath with breath biopsy. However, it is still a great challenge to develop a quick responsive, highly selective, and sensitive VOC-sensing system. The VOC sensors are usually coated with various sensing materials to achieve target-specific detection and real-time monitoring of the VOC molecules in the exhaled breath. These VOC-sensing materials have been the subject of huge interest and extensive research has been done in developing various sensing tools based on electrochemical, chemoresistive, and optical methods. The target-sensitive material with excellent sensing performance and capturing of the VOC molecules can be achieved by optimizing the materials, methods, and its thickness. This review paper extensively provides a detailed literature survey on various non-biological VOC-sensing materials including metal oxides, polymers, composites, and other novel materials. Furthermore, this review provides the associated limitations of each material and a summary table comparing the performance of various sensing materials to give a better insight to the readers.

14 January 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
BRB.M.A. Rahman
B.M.A. Rahman
Charusluk ViphavakitCharusluk Viphavakit
Charusluk Viphavakit
RCRATCHAPAK CHITAREE
RATCHAPAK CHITAREE
SGSouvik Ghosh
Souvik Ghosh
Akhilesh Kumar PathakAkhilesh Kumar Pathak
Akhilesh Kumar Pathak
Natsima SakdaNatsima Sakda
Natsima Sakda
The increasing use of nanomaterials and scalable, high-yield nanofabrication process are revolutionizing the development of novel biosensors. Over the past decades, researches on nanotechnology-mediated biosensing have been on the forefront due to their potential application in healthcare, pharmaceutical, cell diagnosis, drug delivery, and water and air quality monitoring. The advancement of nanoscale science relies on a better understanding of theory, manufacturing and fabrication practices, and the application specific methods. The topology and tunable properties of nanoparticles, a part of nanoscale science, can be changed by different manufacturing processes, which separate them from their bulk counterparts. In the recent past, different nanostructures, such as nanosphere, nanorods, nanofiber, core–shell nanoparticles, nanotubes, and thin films, have been exploited to enhance the detectability of labelled or label-free biological molecules with a high accuracy. Furthermore, these engineered-materials-associated transducing devices, e.g., optical waveguides and metasurface-based scattering media, widened the horizon of biosensors over a broad wavelength range from deep-ultraviolet to far-infrared. This review provides a comprehensive overview of the major scientific achievements in nano-biosensors based on optical fiber, nanomaterials and terahertz-domain metasurface-based refractometric, labelled and label-free nano-biosensors.

25 January 2023 in Photonics
Verified
Journal Article
Open access
PDF file
Akhilesh Kumar PathakAkhilesh Kumar Pathak
Akhilesh Kumar Pathak
Sneha VermaSneha Verma
Sneha Verma
NSNatsima Sakda
Natsima Sakda
Charusluk ViphavakitCharusluk Viphavakit
Charusluk Viphavakit
RCRATCHAPAK CHITAREE
RATCHAPAK CHITAREE
BRB.M.A. Rahman
B.M.A. Rahman
Optical sensing technologies for hydrogen monitoring are of increasing importance in connection with the development and expanded use of hydrogen and for transition to the hydrogen economy. The past decades have witnessed a rapid development of optical sensors for hydrogen monitoring due to their excellent features of being immune to electromagnetic interference, highly sensitive, and widely applicable to a broad range of applications including gas sensing at the sub-ppm range. However, the selection of hydrogen selective metal and metal alloy plays an important role. Considering the major advancements in the field of optical sensing technologies, this review aims to provide an overview of the recent progress in hydrogen monitoring. Additionally, this review highlights the sensing principles, advantages, limitations, and future development.

20 May 2015 in Applied Optics
Verified
Journal Article
Closed access
PDF file
Charusluk ViphavakitCharusluk Viphavakit
Charusluk Viphavakit
MKMichael Komodromos
Michael Komodromos
CTChristos Themistos
Christos Themistos
Waleed S MohammadWaleed S Mohammad
Waleed S Mohammad
Kyriacos KalliKyriacos Kalli
Kyriacos Kalli
BRB.M.A. Rahman
B.M.A. Rahman
A full-vectorial H-field formulation-based finite element approach is used to optimize a biosensor structure incorporating a horizontal slot waveguide. It is designed to detect DNA hybridization through the change of the effective index of the waveguide structure. The key parameters, such as normalized power confinement, power density, change in effective index, and sensitivity are presented by optimizing the device parameters of the slot waveguide. It is shown here that a 90.0 μm long compact Mach–Zehnder section can be designed with horizontal slot waveguide to detect DNA hybridization and for a ring resonator arrangement a sensitivity of 893.5 nm/RIU is obtained.

13 August 2021 in IEEE Sensors Journal
Verified
Journal Article
Closed access
Akhilesh Kumar PathakAkhilesh Kumar Pathak
Akhilesh Kumar Pathak
Charusluk ViphavakitCharusluk Viphavakit
Charusluk Viphavakit
The detection of diabetes at an early stage is considered to be highly significant in the successful treatment of the disease. The patient has been reported to generate unique volatile organic compounds (VOCs) profiles in their exhaled breath which can be utilized as biomarkers to diagnosis the disease conditions. In this article, we theoretically report a simple breath sensor for the highly sensitive detection of isopropanol (IPA), which is the biomarker for both types of diabetes, in exhaled breath using a D-shaped composite plasmonic sensor (DSCPS). The sensing response of the sensor is characterized by using a full-vectorial finite element method (FEM) for the detailed analysis of DSCPS, where a porous TiO 2 (P-TiO 2 ) layer is used as low index sensing material on the top of thin Ag film. The design of the proposed sensor is based on the wavelength modulation technique. A maximum sensitivity of 0.25, 0.35, 0.45, and 1.35 nm/% can be achieved for 20%, 40%, 60%, and 80% volume fraction of IPA, respectively, with a 30% porosity of TiO 2 , which is the maximum filled porous voids that provides the highest sensitivity.

13 December 2024 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
Kankan SwargiaryKankan Swargiary
Kankan Swargiary
STSuphavit Thaneerat
Suphavit Thaneerat
NKNuntaporn Kongsawang
Nuntaporn Kongsawang
Akhilesh Kumar PathakAkhilesh Kumar Pathak
Akhilesh Kumar Pathak
Charusluk ViphavakitCharusluk Viphavakit
Charusluk Viphavakit