Accelerometer-based activity monitors are popular for monitoring physical activity. In this study, we investigated optimal sensor placement for increasing the quality of studies that utilize accelerometer data to assess physical activity. We performed a two-staged study, focused on sensor location and type of mounting. Ten subjects walked at various walking speeds on a treadmill, performed a deskwork protocol, and walked on level ground, while simultaneously wearing five ProMove2 sensors with a snug fit on an elastic waist belt. We found that sensor location, type of activity, and their interaction-effect affected sensor output. The most lateral positions on the waist belt were the least sensitive for interference. The effect of mounting was explored, by making two subjects repeat the experimental protocol with sensors more loosely fitted to the elastic belt. The loose fit resulted in lower sensor output, except for the deskwork protocol, where output was higher. In order to increase the reliability and to reduce the variability of sensor output, researchers should place activity sensors on the most lateral position of a participant’s waist belt. If the sensor hampers free movement, it may be positioned slightly more forward on the belt. Finally, sensors should be fitted tightly to the body.
Objective: With sensors, we are increasingly able to assess sitting behaviour during the day. However, there is no consensus among researchers on the best outcome measures for representing the accumulation of sedentary time during the day. Methods: We analysed the pattern measures of sedentary behaviour. Articles reporting patterns measures in adults, in which behaviour data was collected with a sensor were included. We discuss the strengths and weaknesses of the pattern measures of sedentary behaviour and provide recommendations for choosing objective measures of sedentary behaviour. Results: Most studies report the number of sitting bouts during the day. Others focus on the number of breaks and/or periods of physical activity. Simple measures of sedentary behaviour were most popular. More complex pattern measures, such as the Gini index or the half-life bout duration, that capture the distribution of lengths of sitting periods in a single number, were reported sparsely. The sedentary patterns that were reported in the various studies were difficult to compare, due to the differences among measurement devices, data analysis protocols and a lack of basic outcome parameters such as total wear-time and total sedentary time. Conclusions: Objective sedentary measures can be grouped into simple and complex measures of sedentary time accumulation during the day. These measures serve different goals. The answer to the question as to which measures are most suitable to report, is strongly dependent on the research question. We have shown that the reported measures were dependent on (a) the sensing method, (b) the classification method, (c) the experimental and data cleaning protocol and (d) the applied definitions of bouts and breaks. We recommend that studies should always report total wear-time, total sedentary time, number of bouts and at least one measure describing the diversity of bout lengths in the sedentary behaviour such as the half-life bout duration. Additionally, we recommend reporting the measurement conditions and data processing steps.
Studies that focus on the acceptance of an electronic health (eHealth) technology generally make use of surveys. However, results of such studies hold little value for a redesign, as they focus only on quantifying end-user appreciation of general factors (eg, perceived usefulness). We present a method for understanding end-user acceptance of an eHealth technology, early in the development process: The eHealth End-User Walkthrough. During a walkthrough, a participant is guided by using the technology via a scenario, a persona, and a low-fidelity protoype. A participant is questioned about factors that may affect acceptance during and after the demonstration. We show the value of the method via two case studies. During the case studies, participants commented on whether they intend to use a technology and why they would (not) use its main features. They also provided redesign advice or input for additional functions. Finally, the sessions provide guidance for the generation of business models and implementation plans. The eHealth End-User Walkthrough can aid design teams in understanding the acceptance of their eHealth application in a very early stage of the design process. Consequently, it can prevent a mismatch between technology and end-users' needs, wishes and context.
In the aging society, the need for the elderly to remain mobile and independent is higher than ever. However, many aids supporting mobility often fail to target real needs and lack acceptance. The aim of this study is to demonstrate how value-based design can contribute to the design of mobility aids that address real needs and thus, lead to high acceptance. We elicited values, facilitators, and barriers of mobility of older adults via ten in-depth interviews. Next, we held co-creation sessions, resulting in several designs of innovative mobility aids, which were evaluated for acceptance via nine in-depth interviews. The interviews resulted in a myriad of key values, such as “independence from family” and “doing their own groceries.” Design sessions resulted in three designs for a wheeled walker. Their acceptance was rather low. Current mobility device users were more eager to accept the designs than non-users. The value-based approach offers designers a close look into the lives of the elderly, thereby opening up a wide range of innovation possibilities that better fit their actual needs. Product service systems seem to be a promising focus for targeting human needs in mobility device design.
11 July 2017 in International Journal of Behavioral Medicine
Purpose Increasing physical activity level is a generally effective intervention goal for patients who suffer from chronic cancer-related fatigue (CCRF). However, patients are unlikely to benefit equally from these interventions, as their behavioral starting points might vary substantially. Therefore, we explored patterns of physical behavior of participants who suffer from CCRF. Methods Baseline data of a randomized controlled trial were used for a latent profile analysis on nine accelerometer-derived physical behavior measures, describing levels and patterns of physical activity, moderate-to-vigorous intensity physical activity (MVPA), and sedentary behavior. The relation between participant characteristics and the latent profiles was analyzed. Results Accelerometer data of 172 participants from the Netherlands was analyzed. Three latent profiles were distinguished that differed most on physical activity level and total time spent in MVPA. Eighty-eight percent of all participants were assigned to a profile with a probability higher than 8. Age and perceiving limitations by comorbid conditions and pain were significant covariates of profile membership. Conclusions We distinguished three physical behavior profiles. The differences between the patterns indicate that the heterogeneity of this sample requires patients to have substantially different treatment goals. Further research should test the applicability of these profiles in clinical practice.
Measuring sedentary behaviour and physical activity with wearable sensors provides detailed information on activity patterns and can serve health interventions. At the basis of activity analysis stands the ability to distinguish sedentary from active time. As there is no consensus regarding the optimal cut-point for classifying sedentary behaviour, we studied the consequences of using different cut-points for this type of analysis. We conducted a battery of sitting and walking activities with 14 office workers, wearing the Promove 3D activity sensor to determine the optimal cut-point (in counts per minute (m·s−2)) for classifying sedentary behaviour. Then, 27 office workers wore the sensor for five days. We evaluated the sensitivity of five sedentary pattern measures for various sedentary cut-points and found an optimal cut-point for sedentary behaviour of 1660 × 10−3 m·s−2. Total sedentary time was not sensitive to cut-point changes within ±10% of this optimal cut-point; other sedentary pattern measures were not sensitive to changes within the ±20% interval. The results from studies analyzing sedentary patterns, using different cut-points, can be compared within these boundaries. Furthermore, commercial, hip-worn activity trackers can implement feedback and interventions on sedentary behaviour patterns, using these cut-points.