Direct electricity is widely used for heating purposes in Norway, leading to significant strain on the electricity grid during the heating season. Conversion to 4th generation district heating (4GDH) is an effective method for reducing the need for large investments in the electricity grid, while simultaneously improving the energy efficiency of district heating systems. This article evaluates the possibility of reducing the supply temperature in existing Norwegian apartment blocks by improving the thermal envelope and reducing the temperature levels for the heating system. The analysis is based on simulations in IDA ICE (IDA Indoor Climate and Energy) focusing on whether the reduced supply temperature guarantees thermal comfort in the building, considering the coldest room with a heating setpoint of 22 °C. Based on a recommended minimum acceptable indoor temperature of 19 °C from the Norwegian building regulations (TEK), it should be possible to lower the radiator supply temperature from 80 to 60 °C for apartment blocks newer than 1971. For older buildings, an “intermediate” renovation is necessary to maintain temperatures above 19 °C, however, a “standard” renovation is recommended to ensure thermal comfort and improve the energy efficiency of the building stock.

1 October 2019 in IOP Conference Series: Earth and Environmental Science
Verified
Conference Paper
Open access
PDF file
ØRØystein Rønneseth
Øystein Rønneseth
PLPeng Liu
Peng Liu
MJMaria Justo-Alonso
Maria Justo-Alonso
HMHans Martin Mathisen
Hans Martin Mathisen
Heat recovery in ventilation is essential to reduce energy use and thus mitigate greenhouse gas emissions from the building sector. Heat recovery efficiency of at least 80 % in new buildings is required according to Norwegian standards. However, measurements show that the real heat recovery efficiency during operation is commonly 10-20 % lower. Measuring heat recovery efficiency in buildings is challenging, mainly due to difficulties measuring airflow rates close to the air handling unit (AHU). This study assesses the following duct airflow measurement techniques and equipment: pressure differential, velocity traversal technique, ultrasound and tracer gas. The pressure differential method can provide accurate flow rates and thus it is used as the reference measurement. However, it is not suitable for duct flow measurements due to its high pressure penalty and long straight duct requirement. Velocity traverse and tracer gas methods introduce less disturbance to the flow. Nevertheless, both methods require intensive labour work and cannot track quick changes of the airflow with time. The application of ultrasound to measure airflow is relatively novel and it can automatically measure constant and fluctuating airflows with low pressure drop and acceptable accuracy when the proper installation and minimum straight duct are provided.