Wang Yiwen

Prof. Dr. Wang Yiwen

Harbin University of Science and Technology

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 November 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
WYWang Yiwen
Wang Yiwen
Peng ShenPeng Shen
Peng Shen
MZMinli Zheng
Minli Zheng
PFPengqiang Fu
Pengqiang Fu
LLLijia Liu
Lijia Liu
LYLishan Yuan
Lishan Yuan
A continuous-flow output mode of a rotary blood pump reduces the fluctuation range of arterial blood pressure and easily causes complications. For a centrifugal rotary blood pump, sinusoidal and pulsatile speed patterns are designed using the impeller speed modulation. This study aimed to analyze the hemodynamic characteristics and hemolysis of different speed patterns of a blood pump in patients with heart failure using computational fluid dynamics (CFD) and the lumped parameter model (LPM). The results showed that the impeller with three speed patterns (including the constant speed pattern) met the normal blood demand of the human body. The pulsating flow generated by the impeller speed modulation effectively increased the maximum pulse pressure (PP) to 12.7 mm Hg, but the hemolysis index (HI) in the sinusoidal and pulsatile speed patterns was higher than that in the constant speed pattern, which was about 2.1 × 10−5. The flow path of the pulsating flow field in the spiral groove of the hydrodynamic suspension bearing was uniform, but the alternating high shear stress (0~157 Pa) was caused by the impeller speed modulation, causing blood damage. Therefore, the rational modulation of the impeller speed and the structural optimization of a blood pump are important for improving hydrodynamic characteristics and hemolysis.

11 December 2019 in The International Journal of Advanced Manufacturing Technology
Verified
Journal Article
Closed access
PDF file
CXChengyang Xu
Chengyang Xu
WYWang Yiwen
Wang Yiwen
JXJiazhong Xu
Jiazhong Xu
XLXianli Liu
Xianli Liu

27 October 2021 in Machines
Verified
Journal Article
Open access
PDF file
PSPeng Shen
Peng Shen
WYWang Yiwen
Wang Yiwen
Yun ChenYun Chen
Yun Chen
PFPengqiang Fu
Pengqiang Fu
LZLijie Zhou
Lijie Zhou
LLLijia Liu
Lijia Liu
Rotor suspension stability is one of the important performance indexes of a blood pump and the basis of determining whether the blood pump can be used in a clinic. Compared with the traditional magnetic suspension system, a single-winding, bearingless motor has the advantages of a compact structure, simple control system and low power consumption. In this pursuit, the present study aimed to envisage and design the magnetic suspension system coupled with a single-winding bearingless motor and permanent magnet bearings, establish the theoretical models of axial force and electromagnetic torque, and calculate the stiffness of the magnetic suspension system at the equilibrium point. Addressing the problem of the negative axial stiffness of the magnetic suspension system being negative, which leads to the instability of the suspension rotor, the hydrodynamic bearing structure was proposed and designed, and the critical stiffness to realize the stable suspension of the rotor was obtained based on the stability criterion of the rotor dynamics model. The optimal structural parameters of the hydrodynamic bearing are selected by integrating various factors based on the solution of the Reynolds equation and a stiffness analysis. Furthermore, the vibration experiment results proved that the blood pump rotor exhibited a good suspension stability, and the maximum offset under the impact external fluid was no more than 2 μm.

28 June 2024 in Coatings
Verified
Journal Article
Open access
PDF file
LLLijia Liu
Lijia Liu
WKWenjie Kang
Wenjie Kang
WYWang Yiwen
Wang Yiwen
LZLingchen Zeng
Lingchen Zeng
Biological bone materials, complex and anisotropic, require precise machining in surgeries. Bone drilling, a key technique, is susceptible to increased friction from tool wear, leading to excessive forces and high temperatures that can damage bone and surrounding tissues, affecting recovery. This study develops a monitoring platform to assess tool wear during bone drilling, employing an experimental setup that gathers triaxial force and vibration data. A recognition model using a bidirectional long short-term memory network (BI-LSTM) with a multi-head attention mechanism identified wear levels. This model, termed ABI-LSTM, was optimized and benchmarked against SVR, RNN, and CNN models. The results from implementing the ABI-LSTM-based monitoring system demonstrated its efficacy in detecting tool wear, thereby potentially reducing surgical risks such as osteonecrosis and drill breakage, and enhancing surgical outcomes.

2 September 2025 in Frontiers in Physiology
Verified
Journal Article
Open access
PDF file
HLHongyu Li
Hongyu Li
WYWang Yiwen
Wang Yiwen
XWXuefeng Wu
Xuefeng Wu
LZLijie Zhou
Lijie Zhou
LLLijia Liu
Lijia Liu
The clinical reliability of implantable cardiovascular assist devices (CADs) necessitates rigorous verification by the Mock Circulatory Loop (MCL) to assess their hemodynamic performance, encompassing key parameters such as head, flow, and hemolytic properties. In this paper, we undertake a systematic review of the evolution of this technology system and propose a three-level classification model based on bibliometric analysis (n = 130), in which the dual-circulatory system accounts for 47.27% of the total, to reveal its physiological synergistic mechanism and the innovative application of multi-circulatory configurations in complex clinical scenarios. The study indicates that the prevailing technological impediments pertain to: (i) deviation of 3D-printed vascular mechanical properties (anatomical fidelity loss), (ii) decline in long-term shear force simulation accuracy, and (iii) paucity of module interface compatibility. From an interdisciplinary integration perspective, the present study indicates that adaptive closed-loop hybrid-MCL systems represent a key direction for technological evolution: their architecture, which couples real-time digital twins with physical loops, can dynamically adjust blood flow parameters. When combined with multi-scale simulation optimization, this approach significantly enhances the reliability of long-term shear stress predictions. Furthermore, the integration of personalized digital twins establishes a high-fidelity patient-specific validation platform, thereby providing a theoretical framework for precise evaluation of cardiovascular devices.

2 July 2024 in Medical Engineering & Physics
Verified
Journal Article
Closed access
WYWang Yiwen
Wang Yiwen
CZChangli Zhou
Changli Zhou
XWXuefeng Wu
Xuefeng Wu
LLLijia Liu
Lijia Liu
LDLi Deng
Li Deng
Intimal tears caused by aortic dissection can weaken the arterial wall and lead to aortic aneurysms. However, the effect of different tear states on the blood flow behaviour remains complex. This study uses a novel approach that combines numerical haemodynamic simulation with in vitro experiments to elucidate the effect of arterial dissection rupture on the complex blood flow state within the abdominal aneurysm and the endogenous causes of end-organ malperfusion. Based on the CT imaging data and clinical physiological parameters, the overall arterial models including aortic dissection and aneurysm with single tear and double tear were established, and the turbulence behaviours and haemodynamic characteristics of arterial dissection and aneurysm under different blood pressures were simulated by using non-Newtonian flow fluids with the pulsatile blood flow rate of the clinical patients as a cycle, and the results of the numerical simulation were verified by in vitro simulation experiments. Hemodynamic simulations revealed that the aneurysm and single-tear false lumen generated a maximum pressure of 320.591 mmHg, 267 % over the 120 mmHg criterion. The pressure differential generates reflux, leading to a WSS of 2247.9 Pa at the TL inlet and blood flow velocities of up to 6.41 m/s inducing extend of the inlet. DTD Medium FL instantaneous WP above 120 mmHg Standard 151 % Additionally, there was 82.5 % higher flow in the right iliac aorta than in the left iliac aorta, which triggered malperfusion. Thrombus was accumulated distal to the tear and turbulence. These results are consistent with the findings of the in vitro experiments. This study reveals the haemodynamic mechanisms by which aortic dissection induces aortic aneurysms to produce different risk states. This will contribute to in vitro simulation studies as a new fulcrum in the process of moving from numerical simulation to clinical trials.