Prof. Hun-Chul Seo

Department of Electrical Engineering, Yonam Institute of Technology, Jinju, Korea
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2022 in Energies
Verified
Journal Article
Open access
PDF file
HSHun-Chul Seo
Hun-Chul Seo
The demand for a low voltage direct current (LVDC) microgrid is increasing by the increase of DC-based digital loads and renewable resources and the rapid development of power electronics technology. For the stable operation of an LVDC microgrid, it is necessary to develop a protection method. In this paper, the new protection scheme considering the fault section is proposed using wavelet transform (WT) in an LVDC microgrid. The fault sections are classified into DC side of the alternating current (AC)/DC converter, DC/DC converter connected to photovoltaic (PV) system, DC line, and DC bus. The characteristics of fault current at each fault section are analyzed. Based on these analyses, the new protection scheme including the fault section estimation is proposed using WT. The proposed scheme estimates the fault section using the detail component after performing WT and sends the trip signal to each circuit breaker according to the fault section. The proposed protection scheme is verified through various simulations according to the fault region and fault current using electromagnetic transient program (EMTP)/ATPDraw and MATLAB. The simulation results show that the fault section is accurately determined, and the corresponding circuit breaker (CB) operations are performed.

13 December 2019 in Energies
Verified
Journal Article
Open access
PDF file
HSHun-Chul Seo
Hun-Chul Seo
Owing to the increase in renewable energy, microgrids (MGs) are increasing. A MG has a small loop-type grid configuration. In the loop MG, challenges in protection such as maloperation of protection relay may occur owing to bidirectional current flow. Herein, we propose a new protection scheme in the loop MG. Considerations for protection in loop MG and fault characteristics are analyzed. Based on these, a new index to solve the considerations for MG protection are proposed using a wavelet transform. Furthermore, the new protection scheme based on the coordination with tie switch using the proposed new index is proposed. To verify the proposed scheme, the MG and the proposed scheme are modeled using the electromagnetic transients program and MATLAB. Various simulations according to the fault location and the success/failure of fault section separation are performed. Simulation results indicate that the power supply on the original feeder can be maintained by proposed method.

12 November 2020 in Energies
Verified
Journal Article
Open access
PDF file
HSHun-Chul Seo
Hun-Chul Seo
Loop distribution systems are increasingly used for reasons such as increased distributed generation (DG) and increased demand for a reliable and high-quality power supply. Because the loop distribution system involves bidirectional power flow, the method for protection of the radial distribution system cannot be applied. Therefore, a protection method is proposed herein for loop distribution systems. In this study, the existence of DG is also considered. According to the proposed method, the fault point is estimated on the basis of the equivalent circuit of the distribution system. Then, the fault section is determined and separated from the distribution system. The separation of DG is determined depending on whether the frequency and voltage are maintained within the steady state ranges. The proposed method is modelled and verified using the Electromagnetic Transients Program. Simulations according to the fault location are performed and analyzed. The results show that the method accurately determines the fault section so that normal power can be supplied to the healthy sections in the distribution system.

15 July 2017 in Energies
Verified
Journal Article
Open access
PDF file
HSHun-Chul Seo
Hun-Chul Seo
The conventional reclosing of a distribution system is performed after a fixed dead time. However, it may lead to the increased outage time due to delayed reclosing. To solve this problem, this paper proposes a new adaptive reclosing scheme. The electrostatic induction is analyzed under at during-fault and post-fault conditions. Based on this analysis, the method to judge the fault clearance using the load current is proposed. The reclosing is adaptively performed after fault clearance. The distribution system and reclosing scheme are modelled by the electromagnetic transient program (EMTP). The various simulations according to the unbalanced ratio and various fault conditions are performed and analyzed. The superiority of the proposed scheme is verified by comparing with the conventional reclosing method.

29 August 2022 in Journal of Electrical Engineering & Technology
Verified
Journal Article
Closed access
PDF file
HSHun-Chul Seo
Hun-Chul Seo
GGGi-Hyeon Gwon
Gi-Hyeon Gwon
KPKeon-Woo Park
Keon-Woo Park

7 May 2019 in Energies
Verified
Journal Article
Open access
PDF file
HSHun-Chul Seo
Hun-Chul Seo
Loop power distribution systems are gaining increasing attention due to improvements in the reliability of the power supply and the connection of distributed generation. With loop distribution systems, there is the possibility of mal-operation of the protection relay because of the existence of the tie switch and bi-directional current injection. In this paper, we propose a novel protection scheme considering the tie switch operation in the open loop power distribution system using wavelet transform. We analyze the possibility of mal-operation of the protection relay as a result of the normal load current after tie switch operation and analyze the characteristics of the normal load current and fault current injection after tie switch operation. Using these results, a new index is proposed to distinguish the normal load current and fault current, and a novel protection scheme based on this new index is proposed. The proposed method is modeled using an electromagnetic transients program and MATLAB, and the various simulations are performed according to the tie switch position, the fault location, and the success or failure of the fault section separation. From the simulation results, we can confirm that the normal load current and the fault current after tie switch operation can be accurately distinguished and the protection relay can accurately operate at only fault conditions.