Yusuf Coşkun

Dr. Yusuf Coşkun

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2015 in European Journal Of Cancer Prevention
Verified
Journal Article
Closed access
SKSerta Kilincalp
Serta Kilincalp
ŞÇŞahin Çoban
Şahin Çoban
HAHakan Akinci
Hakan Akinci
MHMevlüt Hamamcı
Mevlüt Hamamcı
FKFatih Karaahmet
Fatih Karaahmet
IYIlhami Yuksel
Ilhami Yuksel
Colorectal cancer (CRC) is the third most common cause of cancer-related death in Europe. The aim of the present study was to elucidate the efficiency of the neutrophil/lymphocyte ratio (NLR), the platelet/lymphocyte ratio (PLR), and the mean platelet volume (MPV) as tools for the preoperative diagnosis of CRC and their usefulness in the follow-up of CRC. A total of 144 CRC patients, as diagnosed by colonoscopy, and 143 age-matched and sex-matched healthy participants were included in the study. Medical records were used to compare preoperative and postoperative data including hemoglobin levels, platelet counts, MPV, NLR, and PLR. NLR, PLR, and MPV were significantly higher in CRC patients preoperatively, compared with healthy participants. Receiver-operating characteristic curve analysis suggested 2.02 as the cutoff value for NLR [area under the curve (AUC): 0.921, sensitivity: 86%, specificity: 84%], 135 as the cutoff value for PLR, (AUC: 0.853, sensitivity: 70%, specificity: 90%) and 8.25 fl as the cutoff value for MPV (AUC: 0.717, sensitivity: 54%, specificity: 76%). Subgroup analysis showed that NLR, PLR, and MPV levels were also significantly higher in nonanemic CRC patients compared with the control group, which is of great theoretical and clinical value for the early detection of CRC. Surgical tumor resection resulted in a significant decrease in NLR, PLR, and MPV. Our results suggest that NLR, PLR, and MPV may be used as easily available additional biomarkers for CRC in screening the general population, as well as in postoperative follow-up.

9 May 2016 in Echocardiography
Verified
Journal Article
Closed access
PDF file
TETolga Han Efe
Tolga Han Efe
TCTolga Cimen
Tolga Cimen
AEAhmet Goktug Ertem
Ahmet Goktug Ertem
YCYusuf Coşkun
Yusuf Coşkun
MBMurat Bilgin
Murat Bilgin
EYEkrem Yeter
Ekrem Yeter

1 July 2019 in European Journal of Gastroenterology & Hepatology
Verified
Journal Article
Closed access
IYIlhami Yuksel
Ilhami Yuksel
SKSerta Kilincalp
Serta Kilincalp
YCYusuf Coşkun
Yusuf Coşkun
HAHakan Akinci
Hakan Akinci
MHMevlut Hamamci
Mevlut Hamamci
AAAfra Alkan
Afra Alkan
Background: Crohn’s disease (CD) is characterised by chronic gastrointestinal inflammation with relapsing–remitting behaviour and often requires endoscopic and/or radiologic assessment. Objective: The objective of this study was to compare the diagnostic accuracy of intestinal ultrasound (IUS) and magnetic resonance enterography (MRE) for the assessment of disease activity in CD using a simple endoscopic score for CD as a reference standard. Patients and methods: A prospective observational study was carried out in 71 consecutive adult patients with known CD, attending our tertiary inflammatory bowel disease clinic, between November 2014 and July 2016. Ileocolonoscopy, IUS and MRE were performed within 1 month prospectively. The simple endoscopic score-CD 0–2 was accepted as remission. Results: The sensitivity of IUS and MRE for detecting endoscopic activity was found similar with regard to bowel wall thickening and mesenteric fibrofatty proliferation (P>0.05). The overall accuracy for detecting mural lesions was similar between IUS and MRE. When mural lesions were analysed, the sensitivity of MRE in detecting the loss of wall stratification and stenosis was significantly higher than IUS (P<0.001 for both). IUS showed higher specificity for bowel wall thickening, loss of wall stratification and stenosis (P=0.009, P<0.001 and P<0.001, respectively). Sensitivity and accuracy of IUS were higher in detecting ascites in active disease (P=0.002). Discussion: Our results showed that IUS and MRE were equally accurate in detecting endoscopic activity. IUS may be the preferred technique for the evaluation of disease activity and for the follow-up of CD.

1 February 2016 in Heart, Lung and Circulation
Verified
Journal Article
Closed access
TETolga Han Efe
Tolga Han Efe
AEAhmet Goktug Ertem
Ahmet Goktug Ertem
YCYusuf Coşkun
Yusuf Coşkun
MBMurat Bilgin
Murat Bilgin
EAEngin Algul
Engin Algul
EYEkrem Yeter
Ekrem Yeter

1 February 2014 in Clinics and Research in Hepatology and Gastroenterology
Verified
Journal Article
Closed access
EEElife Erarslan
Elife Erarslan
YCYusuf Coşkun
Yusuf Coşkun
CTCansel Türkay
Cansel Türkay
AKAslı Köktener
Aslı Köktener
TATimuçin Aydoğan
Timuçin Aydoğan

18 May 2020 in Journal of Gastroenterology and Hepatology
Verified
Journal Article
Closed access
PDF file
YCYusuf Coşkun
Yusuf Coşkun
IYİlhami Yüksel
İlhami Yüksel