Richard L. Hughson

Richard L. Hughson


Research Focus & Metrics

Academic Career Length

52Years (1975-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 1995 in Hypertension
Verified
Journal Article
Closed access
JPJoel Parlow
Joel Parlow
JVJean-Paul Viale
Jean-Paul Viale
GAGuy Annat
Guy Annat
RHRichard L. Hughson
Richard L. Hughson
LQLuc Quintin
Luc Quintin
We compared two methods of assessment of baroreflex sensitivity in eight supine healthy volunteers during repeated baseline measurements and various conditions of cardiac autonomic blockade. The spontaneous baroreflex method involved computer scanning of recordings of continuous finger arterial pressure and electrocardiogram to locate sequences of three or more beats in which pressure spontaneously increased or decreased, with parallel changes in pulse intervals. The mean regression slope of all these sequences during each study condition was considered to represent the mean spontaneous baroreflex slope. In the drug-induced method, sigmoidal curves were constructed from data obtained by bolus injections of phenylephrine and nitroprusside; the tangents taken at the resting pressure of each of these curves were compared with the mean spontaneous baroreflex slopes. The two methods yielded slopes that were highly correlated ( r =.96, P <.001), with significant but similar intraindividual baseline variability. Atropine virtually eliminated the baroreflex slope; subsequent addition of propranolol did not alter it further. Propranolol or clonidine alone increased average baroreflex slope to the extent that they increased resting pulse interval ( r =.69 to .83). The spontaneous baroreflex method provides a reliable, noninvasive assessment of human vagal cardiac baroreflex sensitivity within its physiological operating range.

20 October 2017 in Nature Reviews Cardiology
Verified
Journal Article
Closed access
PDF file
RHRichard L. Hughson
Richard L. Hughson
AHAlexander Helm
Alexander Helm
MDMarco Durante
Marco Durante

1 March 2016 in American Journal of Physiology-Heart and Circulatory Physiology
Verified
Journal Article
Closed access
PDF file
RHRichard L. Hughson
Richard L. Hughson
ARAndrew D. Robertson
Andrew D. Robertson
PAPhilippe Arbeille
Philippe Arbeille
JSJ. Kevin Shoemaker
J. Kevin Shoemaker
JRJames W. E. Rush
James W. E. Rush
DGDanielle K. Greaves
Danielle K. Greaves
Removal of the normal head-to-foot gravity vector and chronic weightlessness during spaceflight might induce cardiovascular and metabolic adaptations related to changes in arterial pressure and reduction in physical activity. We tested hypotheses that stiffness of arteries located above the heart would be increased postflight, and that blood biomarkers inflight would be consistent with changes in vascular function. Possible sex differences in responses were explored in four male and four female astronauts who lived on the International Space Station for 6 mo. Carotid artery distensibility coefficient (P = 0.005) and β-stiffness index (P = 0.006) reflected 17–30% increases in arterial stiffness when measured within 38 h of return to Earth compared with preflight. Spaceflight-by-sex interaction effects were found with greater changes in β-stiffness index in women (P = 0.017), but greater changes in pulse wave transit time in men (P = 0.006). Several blood biomarkers were changed from preflight to inflight, including an increase in an index of insulin resistance (P < 0.001) with a spaceflight-by-sex term suggesting greater change in men (P = 0.034). Spaceflight-by-sex interactions for renin (P = 0.016) and aldosterone (P = 0.010) indicated greater increases in women than men. Six-month spaceflight caused increased arterial stiffness. Altered hydrostatic arterial pressure gradients as well as changes in insulin resistance and other biomarkers might have contributed to alterations in arterial properties, including sex differences between male and female astronauts.

1 April 1999 in Journal of Applied Physiology
Verified
Journal Article
Closed access
PDF file
MTM. E. Tschakovsky
M. E. Tschakovsky
RHRichard L. Hughson
Richard L. Hughson
Considerable debate surrounds the issue of whether the rate of adaptation of skeletal muscle O2consumption (Q˙o2) at the onset of exercise is limited by 1) the inertia of intrinsic cellular metabolic signals and enzyme activation or 2) the availability of O2to the mitochondria, as determined by an extrinsic inertia of convective and diffusive O2transport mechanisms. This review critically examines evidence for both hypotheses and clarifies important limitations in the experimental and theoretical approaches to this issue. A review of biochemical evidence suggests that a given respiratory rate is a function of the net drive of phosphorylation potential and redox potential and cellular mitochondrial[ ](Pmitoo2). Changes in both phosphorylation and redox potential are determined by intrinsic metabolic inertia. Pmitoo2is determined by the extrinsic inertia of both convective and diffusive O2transport mechanisms during the adaptation to exercise and the rate of mitochondrial O2utilization. In a number of exercise conditions, Pmitoo2appears to be within a range capable of modulating muscle metabolism. Within this context, adjustments in the phosphate energy state of the cell would serve as a cytosolic “transducer,” linking ATP consumption with mitochondrial ATP production and, therefore, O2consumption. The availability of reducing equivalents and O2would modulate the rate of adaptation ofQ˙o2.

1 July 2003 in Journal of Applied Physiology
Verified
Journal Article
Open access
PDF file
MTMikko P Tulppo
Mikko P Tulppo
AHArto J. Hautala
Arto J. Hautala
TMTimo H. Mäkikallio
Timo H. Mäkikallio
RLRaija T. Laukkanen
Raija T. Laukkanen
SNSeppo Nissilä
Seppo Nissilä
HHHeikki V. Huikuri
Heikki V. Huikuri
This study was designed to assess the effects of moderate- and high-volume aerobic training on the time domain and on spectral and fractal heart rate (HR) variability indexes. Sedentary subjects were randomized into groups with moderate-volume training ( n = 20), high-volume training ( n = 20), and controls ( n = 15). The training period was 8 wk, including 6 sessions/wk at an intensity of 70–80% of the maximum HR, lasting for 30 min/session in the moderate-volume group and 60 min/session in the high-volume group. Time domain, frequency domain, and short-term fractal scaling measures of HR variability were analyzed over a 24-h period. Mean HR decreased from 70 ± 7 to 64 ± 8 beats/min and from 67 ± 5 to 60 ± 6 beats/min ( P < 0.001 for both) for the moderate- and high-volume training groups, respectively. The normalized high-frequency spectral component increased in both groups ( P < 0.05). The normalized low-frequency component decreased significantly ( P < 0.05), resulting in a marked decrease in low frequency-to-high frequency ratio in both groups. In addition, short-term scaling exponent decreased in both groups ( P < 0.001). There were no significant differences in the changes of HR variability indexes between groups. Aerobic training in sedentary subjects results in altered autonomic regulation of HR toward vagal dominance. A moderate training volume is a sufficient intervention to induce these beneficial effects.

1 October 2015 in Applied Physiology, Nutrition, and Metabolism
Verified
Journal Article
Closed access
RVRodrigo Villar
Rodrigo Villar
TBThomas Beltrame Beltrame
Thomas Beltrame Beltrame
RHRichard L. Hughson
Richard L. Hughson
We tested the validity of the Hexoskin wearable vest to monitor heart rate (HR), breathing rate (BR), tidal volume (VT), minute ventilation, and hip motion intensity (HMI) in comparison with laboratory standard devices during lying, sitting, standing, and walking. Twenty healthy young volunteers participated in this study. First, participants walked 6 min on a treadmill at speeds of 1, 3, and 4.5 km/h followed by increasing treadmill grades until 80% of their predicted maximal heart rate. Second, lying, sitting, and standing tasks were performed (5 min each) followed by 6 min of treadmill walking at 80% of their ventilatory threshold. Analysis of each individual’s mean values under each resting or exercise condition by the 2 measurement systems revealed low coefficient of variation and high intraclass correlation values for HR, BR, and HMI. The Bland–Altman results from HR, BR, and HMI indicated no deviation of the mean value from zero and relatively small variability about the mean. VT and minute ventilation were provided in arbitrary units by the Hexoskin device; however, relative magnitude of change from Hexoskin closely tracked the laboratory standard method. Hexoskin presented low variability, good agreement, and consistency. The Hexoskin wearable vest was a valid and consistent tool to monitor activities typical of daily living such as different body positions (lying, sitting, and standing) and various walking speeds.