Jinji Sun

Dr. Jinji Sun


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2018 in ISA Transactions
Verified
Journal Article
Closed access
JSJinji Sun
Jinji Sun
HZHan Zhou
Han Zhou
XMXin Ma
Xin Ma
ZJZiyan Ju
Ziyan Ju

1 December 2023 in Physiological Measurement
Verified
Journal Article
Closed access
XHXiaole Han
Xiaole Han
JPjiaojiao pang
jiaojiao pang
DXDong Xu
Dong Xu
RWRuizhe Wang
Ruizhe Wang
FXFei Xie
Fei Xie
XNXiaolin Ning
Xiaolin Ning
Objective. This study aimed to develop an automatic and accurate method for severity assessment and localization of coronary artery disease (CAD) based on an optically pumped magnetometer magnetocardiography (MCG) system. Approach. We proposed spatiotemporal features based on the MCG one-dimensional signals, including amplitude, correlation, local binary pattern, and shape features. To estimate the severity of CAD, we classified the stenosis as absence or mild, moderate, or severe cases and extracted a subset of features suitable for assessment. To localize CAD, we classified CAD groups according to the location of the stenosis, including the left anterior descending artery (LAD), left circumflex artery (LCX), and right coronary artery (RCA), and separately extracted a subset of features suitable for determining the three CAD locations. Main results. For CAD severity assessment, a support vector machine (SVM) achieved the best result, with an accuracy of 75.1%, precision of 73.9%, sensitivity of 67.0%, specificity of 88.8%, F1-score of 69.8%, and area under the curve of 0.876. The highest accuracy and corresponding model for determining locations LAD, LCX, and RCA were 94.3% for the SVM, 84.4% for a discriminant analysis model, and 84.9% for the discriminant analysis model. Significance . The developed method enables the implementation of an automated system for severity assessment and localization of CAD. The amplitude and correlation features were key factors for severity assessment and localization. The proposed machine learning method can provide clinicians with an automatic and accurate diagnostic tool for interpreting MCG data related to CAD, possibly promoting clinical acceptance.

1 September 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
BHBangcheng Han
Bangcheng Han
WZweiyong zhou
weiyong zhou
Xueping XuXueping Xu
Xueping Xu
JSJinji Sun
Jinji Sun
FZFengwen Zhao
Fengwen Zhao
JQJiansheng Qin
Jiansheng Qin
With the deepening research in atomic sensors, the extremely weak magnetic detection has shown great advantages in the biomedical field. To achieve high detection sensitivity, the uniform field coil is used in the magnetic detection system to maintain the uniform and stable working environment for the atomic sensors. This paper presents a design method of asymmetric cylindrical uniform field coil based on the boundary element method (BEM) and optimized by the particle swarm optimization algorithm (PSO). BEM could find optimal coil paths on arbitrary geometries, which is fit for the asymmetric configuration in an optically pumped magnetometer based magnetocardiogram (OPM-MCG) device. However, BEM used in the coil design would cause an ill-posed mathematical problem. A Tikhonov regularization combined with penalty function approach is proposed to solve the ill-posed problem and smooth the coil winding patterns, and the correction weights are optimized by PSO within constraints. The calculation results show that the absolute maximum relative error in the target region is optimized to 0.0124% by the proposed method comparing with target field method (TFM) coil (0.023%). Meanwhile, it illustrates that the high uniformity region is enlarged through the utilization of asymmetric structure. In addition, through experiments, the test performance of the designed coil is verified to be consistent with the theory. As the proposed method contributes a high performance uniform field coil on arbitrary structure, it has important significance in extremely weak magnetic field measuring devices such as magnetocardiogram and magnetoencephalogram.

20 April 2023 in Materials
Verified
Journal Article
Open access
PDF file
JSJinji Sun
Jinji Sun
JRJianyi Ren
Jianyi Ren
JLJin Li
Jin Li
YHYuejing Huang
Yuejing Huang
The relative permeability, coercivity, and remanence of permalloy are closely related to the performance of magnetic shielding devices. In this paper, the relationship between the magnetic properties of permalloy and the working temperature of magnetic shielding devices is measured. Firstly, the measurement method of permalloy properties based on the simulated impact method is analyzed. What is more, a magnetic property test system consisting of a soft magnetic material tester and a high–low temperature chamber for permalloy ring samples at different temperatures was established to measure DC and AC (0.01 Hz to 1 kHz) magnetic properties at different temperatures (−60 °C to 140 °C). Finally, the results show that compared with room temperature (25 °C), the initial permeability (μi) decreases by 69.64% at −60 °C and increases by 38.23% at 140 °C, and the coercivity (hc) decreases by 34.81% at −60 °C and increases by 8.93% at 140 °C, which are the key parameters in the magnetic shielding device. It can be concluded that the relative permeability and remanence of permalloy are positively correlated with temperature, while the saturation magnetic flux density and coercivity are negatively correlated with temperature. This paper is of great significance to the magnetic analysis and design of magnetic shielding devices.

1 August 2023 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
XHXiaole Han
Xiaole Han
XXXiaoyan Xue
Xiaoyan Xue
YYYanfei Yang
Yanfei Yang
XLXiaoyu Liang
Xiaoyu Liang
YGYang Gao
Yang Gao
XNXiaolin Ning
Xiaolin Ning
Objective . Optically pumped magnetometers (OPMs) are recently developed magnetocardiography (MCG) sensors that can detect cardiac diseases. This is of great clinical significance for detecting acute myocardial infarction (AMI) and premature ventricular contractions (PVC). This study investigates the use of an array of OPMs to detect heart disease in animals. Approach. An array of OPMs was used to detect the MCG of AMI and PVC in dogs. We used four dogs in this study, and models of AMI with different degrees of severity were established by ligating the middle and proximal segments of the left anterior descending coronary artery. The dogs had PVC at the time of AMI. Continuous MCG time series with corresponding electrocardiograms (ECGs) and average MCG for each dog in different states are presented. The MCG features were extracted from the MCG butterfly diagram, magnetic field map, and pseudo current density map. The MCG features were used to quantify and compare with the gold-standard ECG measures. Main results. The results show that MCG features can accurately distinguish different states of dogs. That is, an array of OPMs can effectively detect AMI and PVC in dogs. Significance. We conclude that the array of OPMs can detect heart diseases in animals. Moreover, OPMs can complement or even replace superconducting quantum interference devices for MCG measurement in animals and diagnosis of human heart diseases in the future.

25 January 2022 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Closed access
SXShilei Xu
Shilei Xu
JSJinji Sun
Jinji Sun
Hongliang RenHongliang Ren
Hongliang Ren
Permanent-magnet (PM) biased magnetic bearings use a magnet to produce the bias field rather than applying a bias current, thereby eliminating the associated electrical power losses and heat generation. In the existing PM-biased magnetic bearings, the PM materials NdFeB or SmCo are generally employed due to their superior properties. However, these PMs should be pre-magnetized, and the generated bias magnetic field cannot be adjusted, limiting the flexibility of the magnetic bearings. This article proposes a new type of PM-biased magnetic bearing that uses a low-coercivity AlNiCo magnet and equips a magnetization coil to magnetize the magnet in situ. As a result, the magnet can be post-magnetized to make the assembly process of the machines easier without the disturbance of magnetic force, and the bias field generated by the magnet can be actively controlled to improve the rotor iron losses and force characteristics of the magnetic bearing. Experiments on a prototype successfully verify the advantages of the presented magnetic bearing.