Currently, in the modern power industry, it is still a great challenge to achieve high sensitivity and uninterrupted-online measurement of large current on the high voltage gridlines. At present, the fiber grating current sensors based on giant magnetostrictive material used in the modern power industry to achieve uninterrupted-online measurement of large currents on high voltage grid lines is a better method, but the sensitivity of this current sensor is relatively low, therefore, it is key to improve the sensitivity of this current sensor. Here we show a sensitivity-enhanced fiber grating current sensor based on giant magnetostrictive material (in the following, simply referred to as the sensitivity-enhanced fiber grating current sensor) that is able to achieve high sensitivity and uninterrupted-online measurement of large currents by means of pressurizing the giant magnetostrictive material. Sampling the power frequency sinusoidal alternating current signals with the amplitudes of 107, 157 and 262 A respectively, based on realistic factors, for the sensitivity-enhanced current sensor, the sensitivities, compared with that of the traditional fiber grating current sensor based on giant magnetostrictive material (in the following, simply referred to as the traditional fiber grating current sensor), were respectively enhanced by 268.96%, 135.72% and 71.57%. Thus the sensitivity-enhanced fiber grating current sensor allows us to solve the issue of high sensitivity and uninterrupted-online measurement of large currents that have been plaguing the power industry in a very simple and low-cost way.
This article presents an extrinsic fiber-optic acoustic sensor applied for partial discharge (PD) detection in air. A Fabry–Perot (F-P) cavity consisting of a single-mode fiber (SMF) and a graphene oxide (GO) film, whose thickness and effective vibration diameter are approximately 500 nm and 4.377 mm, respectively, is used as this sensing core, and the manufacturing process of GO diaphragms and this sensing probe is illustrated to be simple and controllable. Performance tests indicate that this proposed sensor maintains a linear acoustic-pressure response and a flat frequency response in the range of 200 Hz to 20 kHz, while being an omnidirectional sensor and having high working stability during a ten-day test period. Additionally, PD detection results show that the minimum PD size detected by this proposed sensor in air was approximately 100 pC, which demonstrates that this proposed sensor can achieve high-sensitivity PD detection in air.
Cross-linked polyethylene (XLPE) obtained by the crossing-linking reaction of polyethylene (PE) can greatly enhance the mechanical properties and other properties of PE, which makes XLPE widely applied in the field of electric power engineering. However, the space charges can distort the distribution of the electrical field strength in the XLPE applied in the insulation materials, which can shorten the service life of the insulation materials. Therefore, the space charge characteristics of XLPE under the strong direct current (DC) electric field have been the focus of scholars and engineers all over the world. This article has studied the impact of the cross-linking effect on the space charge characteristics of XLPE with different degrees of cross-linking. For this issue, we used dicumyl peroxide (DCP) as the cross-linking agent and low-density polyethylene (LDPE) as the base material for the preparation of samples. Besides, the space charge distribution was measured by the pulsed electro-acoustic method (PEA). In addition, the average charge density as a characteristic parameter was introduced into the experiment, which was used to quantitatively analyze the impact of the cross-linking effect on the space charge characteristics of XLPE with different degrees of cross-linking. Meanwhile, we also explained the impact of the cross-linking effect on XLPE with different degrees of cross-linking from a microscopic point of view. Ultimately, some important conclusions can be obtained. For instance, the cross-linking effect significantly increases the threshold electrical field strength of XLPE, and as the content of cross-linking agent increases, the threshold electrical field strength increases at first and then decreases, and the threshold electrical field strength reaches the maximum value when the content of the cross-linking agent is 1.0% or 2.1%. Besides, the cross-linking effect introduces negative charge traps into the LDPE and increases the densities of the deeper charge traps, and so on. In addition, we have also analyzed the average charge density, and we have summarized the theoretical model of the average charge decay, namely, , which is very effective for explaining the dissipation characteristics (more conclusive contents can be seen in the conclusion section of this article).
This article presents the influence of thermal aging on space charge accumulation and dissipation of cross-linked polyethylene (XLPE) with different cross-linking agent contents. In this article, dicumyl peroxide (DCP) and low-density polyethylene (LDPE) respectively are used as cross-linking agent and basic experimental material. Additionally, an improved PEA method is used to measure space charge densities during voltage application and removal when thermal aging time respectively is 0, 5, 15, 30 and 80 days due to higher accuracy. And experimental results indicate thermal aging can introduce negative charge traps into pure LDPE and make space charges easier to inject and accumulate in pure LDPE and XLPE, but space charge densities in XLPE increase more rapidly as thermal aging time increases, moreover, thermal aging can simultaneously increase densities of deep and shallow charge traps in pure LDPE and XLPE, etc. And we have also explained the change of space charge accumulation and dissipation of pure LDPE and XLPE after thermal aging from the perspective of micro-structure change of pure LDPE and XLPE through the quantitative analysis of average charge densities. Besides, theoretical model of the average charge decay has also been summed up, and this model can perfectly reflect the dissipation of space charges in pure LDPE and XLPE of different thermal aging time.