Hiroshi Kumagai

Dr. Hiroshi Kumagai

orcid

Research Focus & Metrics

Academic Career Length

36Years (1991-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 April 2021 in Journal of Artificial Organs
Verified
Journal Article
Open access
PDF file
TFToru Funayama
Toru Funayama
HNHiroshi Noguchi
Hiroshi Noguchi
HKHiroshi Kumagai
Hiroshi Kumagai
KSKosuke Sato
Kosuke Sato
TYTomokazu Yoshioka
Tomokazu Yoshioka
Masashi YamazakiMasashi Yamazaki
Masashi Yamazaki
In Japan, where allograft bone transplantation is not widespread, prospects for artificial bones are very high. Therefore, artificial bones with various compositions, porous structures, and porosities have been developed and employed for clinical use. Both Affinos® and Regenos® (made of beta-tricalcium phosphate and hydroxyapatite, respectively) are artificial bones with a unique unidirectional porous structure, in which pores with a diameter suitable for tissue penetration (25–300 μm) are aligned in one direction. The unidirectional porous structure allows rapid penetration of blood deep into the materials by a capillary effect. In animal experiments, Affinos® showed well-balanced resorption and was replaced with the host’s own bone from an early stage after implantation and new bone formation and remodeling were observed in the cortical bone and medullary cavity. When implanted for clinical situation, resorption from an early stage and good replacement with the patient’s own bone were also observed. Regenos® has an internal osteon-like material and a vascular-like structure that is maintained within the pores even after long-term implantation, as noted in an animal experiment. When implanted for clinical situation, good osteoconductivity was observed from an early stage of implantation. In addition, the material was observed to be slowly absorbed over time in some cases. We have discussed the beneficial effects of combining teriparatide and platelet-rich plasma impregnation and the potential prospects of these artificial bones.

28 February 2021 in Asian Spine Journal
Verified
Journal Article
Open access
PDF file
KMKousei Miura
Kousei Miura
HKHideki Kadone
Hideki Kadone
TATetsuya Abe
Tetsuya Abe
MKMasao Koda
Masao Koda
TFToru Funayama
Toru Funayama
Masashi YamazakiMasashi Yamazaki
Masashi Yamazaki
Study Design: Prospective experimental study in humans.Purpose: To determine whether the hybrid assistive limb (HAL) for Care Support can reduce lumbar load during a patient transfer.Overview of Literature: The prevalence of work-related low back pain (LBP) among nurses is high. In particular, transferring patients poses a high risk for LBP due to the large lumbar load. Attempts to reduce the lumbar load are crucial to avoid the risk of LBP. Therefore, we investigated the effects of the HAL for Care Support.Methods: Nineteen volunteers (16 men, three women) lifted a 60-kg doll from a seated position to a standing position. The first transfer was performed without the HAL for Care Support, and the second was performed with the HAL for Care Support assistive robot. We evaluated transfer performance, the visual analog scale (VAS) score for lumbar fatigue, and electromyogram analyses of the trunk and hip.Results: Four participants (two men, two women) succeeded with the HAL for Care Support even though they were unable to perform the task without it. The mean lumbar fatigue VAS score for all participants without the HAL for Care Support was 62 mm, while that with it was 43 mm. With lumbar assistance from the HAL for Care Support, subjective lumbar fatigue during the transfer decreased significantly. A power analysis indicated adequate statistical power to detect a difference in the VAS score for lumbar fatigue (0.99). The activity of the left gluteus maximus alone increased significantly during transfers with the HAL for Care Support. No adverse events occurred during use of the HAL for Care Support for transfers.Conclusions: The HAL for Care Support was able to reduce lumbar load in a simulated patient transfer.

1 January 2019 in Journal of Clinical Neuroscience
Verified
Journal Article
Closed access
HKHiroshi Kumagai
Hiroshi Kumagai
TATetsuya Abe
Tetsuya Abe
MKMasao Koda
Masao Koda
KNKatsuya Nagashima
Katsuya Nagashima
KMKousei Miura
Kousei Miura
Masashi YamazakiMasashi Yamazaki
Masashi Yamazaki

19 July 2019 in Journal of Artificial Organs
Verified
Journal Article
Closed access
PDF file
HKHiroshi Kumagai
Hiroshi Kumagai
TMTakeshi Makihara
Takeshi Makihara
TFToru Funayama
Toru Funayama
KSKosuke Sato
Kosuke Sato
HNHiroshi Noguchi
Hiroshi Noguchi
Masashi YamazakiMasashi Yamazaki
Masashi Yamazaki


1 October 2018 in Journal of Clinical Neuroscience
Verified
Journal Article
Closed access
HNHiroshi Noguchi
Hiroshi Noguchi
MKMasao Koda
Masao Koda
TFToru Funayama
Toru Funayama
HKHiroshi Kumagai
Hiroshi Kumagai
JSJunya Saito
Junya Saito
MYMasashi Yamazaki
Masashi Yamazaki