Background: Due to its easy applicability, pulse wave has been proposed as a surrogate of electrocardiogram (ECG) for the analysis of heart rate variability (HRV). However, its smoother waveform precludes accurate measurement of pulse-to-pulse interval by fiducial-point algorithms. Here we report a pulse frequency demodulation (PFDM) technique as a method for extracting instantaneous pulse rate function directly from pulse wave signal and its usefulness for assessing pulse rate variability (PRV). Methods: Simulated pulse wave signals with known pulse interval functions and actual pulse wave signals obtained from 30 subjects with a trans-dermal pulse wave device were analyzed by PFDM. The results were compared with heart rate and HRV assessed from simultaneously recorded ECG. Results: Analysis of simulated data revealed that the PFDM faithfully demodulates source interval function with preserving the frequency characteristics of the function, even when the intervals fluctuate rapidly over a wide range and when the signals include fluctuations in pulse height and baseline. Analysis of actual data revealed that individual means of low and high frequency components of PRV showed good agreement with those of HRV (intraclass correlation coefficient, 0.997 and 0.981, respectively). Conclusion: The PFDM of pulse wave signal provides a reliable assessment of PRV. Given the popularity of pulse wave equipments, PFDM may open new ways to the studies of long-term assessment of cardiovascular variability and dynamics.
Streetscapes are basic urban elements which play a major role in the livability of a city. The visual complexity of streetscapes is known to influence how people behave in such built spaces. However, how and which characteristics of a visual scene influence our perception of complexity have yet to be fully understood. This study proposes a method to evaluate the complexity perceived in streetscapes based on the statistics of local contrast and spatial frequency. Here, 74 streetscape images from four cities, including daytime and nighttime scenes, were ranked for complexity by 40 participants. Image processing was then used to locally segment contrast and spatial frequency in the streetscapes. The statistics of these characteristics were extracted and later combined to form a single objective measure. The direct use of statistics revealed structural or morphological patterns in streetscapes related to the perception of complexity. Furthermore, in comparison to conventional measures of visual complexity, the proposed objective measure exhibits a higher correlation with the opinion of the participants. Also, the performance of this method is more robust regarding different time scenarios.
Independent component analysis (ICA) is a powerful tool for separating signals from their mixtures. In this field, many algorithms were proposed, but they poorly use a priori information in order to find the desired signal. Here, we propose a fixed point algorithm which uses a priori information to find the signal of interest out of a number of sensors. We particularly applied the algorithm to cancel cardiac artifacts from a magnetoencephalogram.
1 January 2001 in IEEE Transactions on Biomedical Engineering
The authors' study focuses on a new method of estimating the heart rate variability (HRV) which does not require the use of electrocardiogram (ECG) R-wave detection. Contrary to the R-wave detection method which requires a sampling frequency higher than 100 Hz, the one proposed here can be used to calculate the HRV from an ECG signal sampled at a frequency of approximately 5 Hz with a relative mean error of 0.03. This new method is based on extracting the instantaneous fundamental frequency from the EGG. The method could be efficiently used to extract the HRV from an ECG measured for healthy subjects performing an exercise in which the HRV increases linearly with time, and for subjects with respiratory and cardiac problems. The overall error decreased as the authors low-pass filtered the HRV with lower cut-off frequencies. Moreover, it was shown that the method could be efficiently used to calculate the HRV from blood pressure measurements and to be robust to noise.