Junzhi Wang

Dr. Junzhi Wang

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 July 2021 in Journal of Pharmaceutical Analysis
Verified
Journal Article
Open access
XQXi Qin
Xi Qin
MDMaoqin Duan
Maoqin Duan
DPDening Pei
Dening Pei
JLJian Lin
Jian Lin
LWLan Wang
Lan Wang
JWJunzhi Wang
Junzhi Wang
Recombinant human interferon α2b (rhIFNα2b) is widely used as an antiviral therapy agent for the treatment of hepatitis B and hepatitis C. The current identification test for rhIFNα2b is complex. In this study, an anti-rhIFNα2b nanobody was discovered and used for the development of a rapid lateral flow strip for the identification of rhIFNα2b. RhIFNα2b was used to immunize an alpaca, which established a phage nanobody library. After five steps of enrichment, the nanobody I22, which specifically bound rhIFNα2b, was isolated and inserted into the prokaryotic expression vector pET28a. After subsequent purification, the physicochemical properties of the nanobody were determined. A semiquantitative detection and rapid identification assay of rhIFNα2b was developed using this novel nanobody. To develop a rapid test, the nanobody I22 was coupled with a colloidal gold to produce lateral-flow test strips. The developed rhIFNα2b detection assay had a limit of detection of 1 μg/mL. The isolation of I22 and successful construction of a lateral-flow immunochromatographic test strip demonstrated the feasibility of performing ligand-binding assays on a lateral-flow test strip using recombinant protein products. The principle of this novel assay is generally applicable for the rapid testing of other commercial products, with a great potential for routine use in detecting counterfeit recombinant protein products.

1 November 2014 in Journal of Pharmaceutical and Biomedical Analysis
Verified
Journal Article
Open access
YYYushuai Yang
Yushuai Yang
YZYong Zhou
Yong Zhou
LYLei Yu
Lei Yu
XLXiang Li
Xiang Li
XSXinchang Shi
Xinchang Shi
JWJunzhi Wang
Junzhi Wang
Accurate determination of in vitro biological activity of therapeutic erythropoietin is essential in quality control of recombinant human erythropoietin (rHuEPO) pharmaceutical products. However, most of currently-used methods leave much to be desired so that a simpler, quicker and more accurate method is urgently needed. The bioassay described here utilizes a sub clone of UT-7/epo cell line stably transfected with luciferase gene under the control of sis inducible element and interferon γ-activated sequence element promoter. Active erythropoietin could induce the expression of luciferase by signaling through the erythropoietin receptor and the dose-response curve showed good linearity, yielding a coefficient of determination of 0.99 or higher. The optimized assay was simpler with the operation completed within 24h and more sensitive with EC50 being 0.077IU/mL. The accuracy estimates ranged from 81.7% to 102.4%, and both intra-assay and inter-assay precision was below 15.0%. The robustness of the assay was demonstrated by no effect of passage levels of the cells on the performance of the assay (p values: 0.772 for sample 1 and 0.943 for sample 2). Besides, Bland-Altman analysis showed a high consistency of the new assay with in vivo reticulocyte assay in results. These results suggested that the new reporter gene assay can be a viable supplement to the traditional reticulocyte assay and employed in potency determination of rHuEPO pharmaceutical products.

17 September 2021 in Acta Pharmaceutica Sinica B
Verified
Journal Article
Open access
ZFZhihao Fu
Zhihao Fu
HLHongchuan Liu
Hongchuan Liu
LWLan Wang
Lan Wang
CYChuanfei Yu
Chuanfei Yu
YYYalan Yang
Yalan Yang
JWJunzhi Wang
Junzhi Wang
T cell immunoglobulin and ITIM domain (TIGIT) is a novel immune checkpoint that has been considered as a target in cancer immunotherapy. Current available bioassays for measuring the biological activity of therapeutic antibodies targeting TIGIT are restricted to mechanistic investigations because donor primary T cells are highly variable. Here, we designed a reporter gene assay comprising two cell lines, namely, CHO-CD112-CD3 scFv, which stably expresses CD112 (PVRL2, nectin-2) and a membrane-bound anti-CD3 single-chain fragment variable (scFv) as the target cell, and Jurkat-NFAT-TIGIT, which stably expresses TIGIT as well as the nuclear factor of activated T-cells (NFAT) response element-controlled luciferase gene, as the effector cell. The anti-CD3 scFv situated on the target cells activates Jurkat-NFAT-TIGIT cells through binding and crosslinking CD3 molecules of the effector cell, whereas interactions between CD112 and TIGIT prevent activation. The presence of anti-TIGIT mAbs disrupts their interaction, which in turn reverses the inactivation and luciferase expression. Optimization and validation studies have demonstrated that this assay is superior in terms of specificity, accuracy, linearity, and precision. In summary, this reliable and effective reporter gene assay may potentially be utilized in lot release control, stability assays, screening, and development of novel TIGIT-targeted therapeutic antibodies.

11 February 2024 in Analytica Chimica Acta
Verified
Journal Article
Closed access
GWGang Wu
Gang Wu
JDJialiang Du
Jialiang Du
CYChuanfei Yu
Chuanfei Yu
ZFZhihao Fu
Zhihao Fu
XZXiaoxi Zhang
Xiaoxi Zhang
JWJunzhi Wang
Junzhi Wang

1 January 2018 in Journal of Pharmaceutical and Biomedical Analysis
Verified
Journal Article
Closed access
ZFZhihao Fu
Zhihao Fu
CYChuanfei Yu
Chuanfei Yu
LWLan Wang
Lan Wang
KGKai Gao
Kai Gao
GXGangling Xu
Gangling Xu
JWJunzhi Wang
Junzhi Wang

29 May 2024 in Journal of Chromatography B
Verified
Journal Article
Closed access
GWGang Wu
Gang Wu
CYChuanfei Yu
Chuanfei Yu
SYSicheng Yin
Sicheng Yin
JDJialiang Du
Jialiang Du
YZYifan Zhang
Yifan Zhang
JWJunzhi Wang
Junzhi Wang